Introduction
This manual provides instructions for the safe and efficient operation and maintenance of your Jebao DCP Series DC Pump. The Jebao DCP series are super quiet, energy-saving pumps designed for various water applications, including fish tanks and aquariums. Please read this manual thoroughly before installation and use.
Safety Information
- Always disconnect power before performing any maintenance or installation.
- Ensure the pump is used with the correct voltage (110-240V).
- Do not operate the pump dry.
- Keep the controller dry and away from water.
- This pump is designed for water applications; do not use it for other liquids.
Setup
1. Unpacking and Inspection
Carefully remove all components from the packaging. Inspect the pump, controller, and accessories for any signs of damage. If any damage is found, do not proceed with installation and contact your supplier.

Image: Jebao DCP pump and its controller unit.
2. Placement (Amphibious Use)
The Jebao DCP pump is designed for amphibious use, meaning it can be used both submerged in water (diving use) or placed on land for water transport (land use). For optimal performance and longevity, diving use (submerged in water to promote circulation) is recommended.

Image: Diagram illustrating recommended diving use (submerged) and land use (not recommended) for the pump.
3. Connecting Hoses and Pipes
The pump comes with multiple connectors to accommodate various hose and pipe sizes. Each model is equipped with a connection hose and rigid pipe joints. Select the appropriate connectors for your setup.

Image: Various nuts, hose connectors, and O-rings for connecting different hose sizes.
Refer to the table below for specific nut and hose connector sizes for each model:
| Model | Nut (inch) | Hose connector (inch) | Hose connector (inch) |
|---|---|---|---|
| DCP2000 | 2个 3/4" | / | 2个 3/4",2个 5/8" |
| DCP2500 | 2个 1/8" | 2个 3/4" | 1个 1",1个 3/4" |
| DCP3000/4000 | 1个 1 3/8",1个 1 1/8" | 1个 1",1个 3/4" | 1个 1",1个 3/4" |
| DCP5000-10000 | 2个 1 3/4" | 2个 1 1/4",2个 1",2个 3/4" | 1个 1 1/2",1个 1 1/4",1个 1",1个 3/4" |
| DCP15000/18000 | 2个 2 1/4" | 2个 1 1/2",2个 1 1/4" | 1个 2",1个 1 1/2",1个 1 1/4" |
Table: Nut and hose connector sizes for various DCP pump models.
4. Power Connection
Connect the pump to the controller, and then connect the controller to a suitable power outlet using the provided adapter plug. The pump operates on 110-240V. Ensure the adapter plug matches your local electrical standards (US, EU, UK, AU).

Image: Examples of AU, US, UK, and EU adapter plugs. Note that a local adapter plug is provided, which may be a converter type.
Operating Instructions
1. Controller Functions
The Jebao DCP pump features a touch screen controller for real-time power display and flow rate adjustment. The controller utilizes SINE Wave Technology for quiet and smooth operation.

Image: Controller showing LED display, up/down arrows for flow adjustment, and a pause button.
- Adjusting Flow Rate: Press the "↑" or "↓" buttons to increase or decrease the water flow rate. The LED display will show the current power consumption in watts.
- Feeding Mode: Press the "||" (pause) button to activate feeding mode. The pump will pause for 10 minutes and then resume normal operation automatically.

Image: Close-up of the controller's LED display, emphasizing real-time power adjustment.
2. Sine Wave Technology
The DCP series pumps incorporate advanced Sine Wave Technology, which contributes to their ultra-quiet operation, smooth performance, and high efficiency compared to traditional square wave pumps.

Image: Comparison of sine wave and square wave, highlighting the superior silence and quality of sine wave technology.
Maintenance
Regular maintenance ensures the longevity and optimal performance of your Jebao DCP pump.
1. Impeller Cleaning
The pump features a closed impeller turbo design. Over time, debris can accumulate around the impeller, reducing efficiency. Periodically, disconnect the pump from power, remove the front cover, and clean the impeller and its housing. Ensure all parts are reassembled correctly.

Image: Close-up view of the pump's closed impeller turbo design.
2. Seal Inspection
The pump utilizes a unique ring seal design to ensure watertight operation. Regularly inspect the O-rings and seals for wear or damage. Replace them if necessary to prevent leaks.

Image: Detail of the pump's watertight ring seal design.
Troubleshooting
- Pump not turning on:
- Check if the power adapter is securely connected to both the controller and the power outlet.
- Ensure the power outlet is functional.
- Verify that the correct adapter plug type (US, EU, UK, AU) is being used and that it is properly connected.
- Reduced flow rate:
- Check for blockages in the pump's intake or outlet.
- Clean the impeller and pump housing for any accumulated debris.
- Ensure hoses are not kinked or obstructed.
- Adjust the flow rate using the controller's up/down buttons.
- Unusual noise:
- Disconnect power and check the impeller for any foreign objects.
- Ensure the pump is properly submerged if used in diving mode, or securely placed if used on land.
Specifications
The Jebao DCP series pumps are available in various models with different performance characteristics. Below is a detailed parameters table:

Image: Table detailing model, voltage, power, head, flow, and product size for various DCP pumps.
| Model | Voltage (V) | Power (W) | Head (M) | Flow (L/H) | Product Size (MM) |
|---|---|---|---|---|---|
| DCP-2500 | DC 24V | 23 | 2.5 | 2500 | 103*73*98 |
| DCP-3000 | DC 24V | 25 | 3.0 | 3000 | 135*80*105 |
| DCP-4000 | DC 24V | 32 | 4.0 | 4000 | 135*80*105 |
| DCP-5000 | 40 | 4.0 | 5500 | 163*104*129 | |
| DCP-6500 | DC 24V | 55 | 4.5 | 6500 | 163*104*129 |
| DCP-8000 | DC 24V | 65 | 5.5 | 8000 | 163*104*129 |
| DCP-10000 | DC 24V | 80 | 6.0 | 10000 | 163*104*129 |
| DCP-15000 | DC 24V | 105 | 7.0 | 15000 | 190*126*159 |
| DCP-18000 | DC 36V | 130 | 9.0 | 18000 | 190*126*159 |
Table: Detailed specifications for Jebao DCP pump models.
Water Flow Performance

Image: Graph showing the relationship between pump head (M) and flow rate (L/H) for various DCP models.
General Specifications
- Material: Rubber
- Fixed Form: Sitting
- Voltage: 110-240V
- Origin: Mainland China
Warranty and Support
For any issues or inquiries regarding your Jebao DCP pump, please contact your seller or the manufacturer's customer support. It is recommended to keep your purchase receipt for warranty purposes.
If you experience any problems, clear communication with the seller can often lead to a satisfactory solution.
User Tips
- Consider your needs: Some users found that they could have benefited from a larger pump model than initially purchased, so carefully assess your flow rate and head requirements for your specific setup.
- Quiet Operation: The pump is generally praised for its quiet operation, thanks to its sine wave technology, making it suitable for environments where noise is a concern.
- Adapter Type: Be aware that the provided adapter plug might be a converter type rather than a native cable for your region. Ensure it is securely connected and suitable for your power outlets.
- Durability: Users generally report good quality and robust construction, suggesting reliable performance over time.