UandaGad GP4-WLTE

GP4-WLTE 4-Channel 4G Smart Controller User Manual

Model: GP4-WLTE

Brand: UandaGad

1. Introduction

The GP4-WLTE is a versatile 4-channel Digital Input (DI), Digital Output (DO), and Analog Quantity Input (AI) 4G remote controller. It is designed for various industrial and automation applications, offering remote control and monitoring capabilities via APP, SMS, and Web interfaces. This manual provides detailed instructions for setting up, operating, and maintaining your GP4-WLTE controller.

Attention: This device supports only 2G/4G networks and does not support 3G.

Model GP4-WLTE-EA does not support power failure alarm. Model GP4-WLTE-EC supports power failure alarm.

2. Key Features

  • 4-Channel Analog Input (AI): Supports 4 channels of 4~20mA input with 12-bit accuracy.
  • 4-Channel Digital Input (DI): Supports passive switch values (dry contact) for detection.
  • 4-Channel Digital Output (DO): Equipped with relay outputs (10A@AC250V/DC30V). Each relay has an independent indicator for immediate status identification.
  • Multiple Control Methods: Supports control via dedicated 'WLTE Control' APP, SMS commands, and Web interface.
  • Communication Protocols: Provides TCP/HTTP protocols for integration with custom server platforms.
  • RS-485 Support: Offers a simple RS-485 communication document for control and data retrieval via Modbus protocol.
  • Wide Voltage Input: Operates within a working voltage range of 9-24V DC, suitable for various industrial environments.
  • Remote Linkage Actions: Supports AI/DI with remote linkage actions for complex automation logic.
  • SMS Alarms: Configurable SMS alarms for events such as analog thresholds being met.
  • Power Failure Alert: GP4-WLTE-EC model includes power failure alert functionality.

3. Package Contents

Verify that all items are present in your package:

  • GP4-WLTE Smart 4G Controller
  • 4G Antenna
  • Power Adapter (EU/AU/US/UK Plug, depending on region)
  • User Manual (this document)
GP4-WLTE package contents including controller, antenna, and power adapter.
Figure 3.1: GP4-WLTE Product List
GP4-WLTE-EA model with power adapter.
Figure 3.2: GP4-WLTE-EA Model with Power Adapter

4. Specifications

FeatureSpecification
Brand NameUandaGad
Model NumberGP4-WLTE-EA / GP4-WLTE-EC
OriginMainland China
CertificationCE
DC Power Supply9-24V DC (Standard adapter DC12V/500mA)
Power ConsumptionStandby 12V/50mA, Working Max 12V/200mA
4G Frequency (LTE-FDD)EA/EC: B1/B3/B5/B7/B8/B20
GA/GC: B1/B2/B3/B4/B5/B7/B8/B20/B28/B66
GSM Frequency (2G)EA/EC: 900/1800 MHz
GA/GC: 850/900/1800/1900 MHz
SIM InterfaceStandard Micro SIM card
Antenna InterfaceStandard SMA interface
Relay Outputs4 channels, 10A/250VAC, 15A/125VAC
Output LogicNormally Open (NO) and Normally Closed (NC)
DI Input Type4 channels Dry-contact inputs
Analog Input Type4 channels 4-20mA analog inputs
Shell Size155mm x 65mm x 32mm
Box Size190mm x 120mm x 50mm
GP4-WLTE-EA Gross Weight450g
GP4-WLTE-EA Net Weight280g
GP4-WLTE-EC Gross Weight460g
GP4-WLTE-EC Net Weight290g
Table of GP4-WLTE product parameters and specifications.
Figure 4.1: Detailed Product Parameters
Image showing the product list and dimensions of the GP4-WLTE controller.
Figure 4.2: Product Dimensions

5. Safety Information

  • Ensure the power supply voltage is within the specified range (9-24V DC).
  • All wiring should be performed by qualified personnel to prevent electrical hazards.
  • Disconnect power before performing any wiring or maintenance.
  • Do not expose the device to extreme temperatures, humidity, or corrosive environments.
  • Keep the device away from water and other liquids.
  • The power of DC motors directly controlled by the relay must be less than 80W. For higher power AC motors, an AC contactor is required.

6. Setup

6.1 Device Overview

Top view of the GP4-WLTE controller showing all connection ports and indicators.
Figure 6.1: GP4-WLTE Controller Top View
Detailed diagram of the GP4-WLTE interface, showing output indicators, relay outputs, dry-contact inputs, analog inputs, RS485, power, SIM card, and antenna ports.
Figure 6.2: GP4-WLTE Interface Diagram

6.2 SIM Card Installation

  1. Locate the Micro SIM card slot on the device.
  2. Insert a standard Micro SIM card into the slot. Ensure it is correctly oriented.

6.3 Antenna Connection

  1. Locate the SMA antenna interface on the device.
  2. Screw the provided 4G antenna onto the SMA connector until secure.

6.4 Power Connection

  1. Connect the provided power adapter to the DC Power input port (9-24V DC).
  2. Plug the power adapter into a suitable power outlet. The device will power on.

6.5 Wiring Diagrams

Important: Circuit wiring requires professional operation. Please handle it carefully.

6.5.1 Dry-Contact Input Wiring

Wiring diagram for dry-contact inputs, showing connections for passive switches and an electric door with level and wired door sensors.
Figure 6.3: Dry-Contact Input Wiring

The GP4-WLTE supports 4 channels of dry-contact inputs (DI1-DI4). Connect passive switches or sensors that provide a dry-contact output to these terminals. The diagram illustrates connecting to a passive switch/micro switch and an electric door with a level switch or wired door sensor.

6.5.2 Output Wiring (Relay Control)

Output wiring diagrams for controlling DC motors, AC bulbs/LEDs, high-power AC motors (two-phase and three-phase), and access systems.
Figure 6.4: Output Wiring Diagram

The GP4-WLTE provides 4 relay outputs (COM1-COM4) with Normally Open (NO) and Normally Closed (NC) contacts. These can be used to control various devices:

  • DC Motor or Other Device (Power below 80W): Connect the motor directly to the relay contacts.
  • AC Bulb/LED/Device (Power below 200W): Connect the AC load directly to the relay contacts.
  • High-Power AC Motor Control (More than 400W): Use an external AC contactor. The GP4-WLTE relay controls the coil of the AC contactor, which in turn controls the high-power motor. This applies to both two-phase and three-phase motors.
  • Access System Application: Connect the relay to control electronic locks or other access control components.

6.5.3 Analog Input Sensor Wiring

The GP4-WLTE supports 4 channels of 4-20mA analog inputs (AI1-AI4). Various 4-20mA transmitters can be connected, such as pressure, temperature, hydrogen sulfide, PT100, current, wind pressure, liquid level, and water temperature sensors.

Examples of various 4-20mA transmitters including pressure, temperature, PT100, liquid level, and more.
Figure 6.5: Compatible 4-20mA Transmitters
Wind Speed Sensor Wiring Diagram
Wiring diagram for a wind speed sensor to the GP4-WLTE controller, showing connections for VCC, GND, and AI2, along with APP configuration steps.
Figure 6.6: Wind Speed Sensor Wiring and APP Configuration

Connect the brown wire of the wind speed sensor to VCC, the black wire to GND, and the blue wire to AI2. Follow the APP configuration steps in Section 7.1.3 to set up the analog input for wind speed.

PT100 Transmitter Wiring Diagram
Wiring diagram for a PT100 transmitter to the GP4-WLTE controller, showing connections for VCC, GND, and AI1, along with APP configuration steps.
Figure 6.7: PT100 Transmitter Wiring and APP Configuration

Connect the red wire of the PT100 transmitter to VCC, the black wire to GND, and the blue wire to AI1. Follow the APP configuration steps in Section 7.1.3 to set up the analog input for PT100 temperature.

Liquid Level Sensor Wiring Diagram
Wiring diagram for a liquid level sensor to the GP4-WLTE controller, showing connections for VCC, GND, and AI1, along with APP configuration steps.
Figure 6.8: Liquid Level Sensor Wiring and APP Configuration

Connect the red wire of the liquid level sensor to VCC, the black wire to GND, and the blue wire to AI1. Follow the APP configuration steps in Section 7.1.3 to set up the analog input for liquid level.

Soil Temperature and Humidity Sensor Wiring Diagram
Wiring diagram for a soil temperature and humidity sensor to the GP4-WLTE controller, showing connections for VCC, GND, AI3, and AI4, along with APP configuration steps.
Figure 6.9: Soil Temperature and Humidity Sensor Wiring and APP Configuration

Connect the brown wire of the soil sensor to VCC, the black wire to GND, the yellow wire to AI3 (Soil Temperature Analog Output), and the blue wire to AI4 (Soil Humidity Analog Output). Follow the APP configuration steps in Section 7.1.3 to set up the analog inputs for soil temperature and humidity.

Video 6.1: Demonstrates wiring and APP configuration for a soil temperature and humidity sensor, including setting sensor limits and observing data changes when exposed to cold water.

7. Operation

7.1 APP Control ('WLTE Control')

The primary control method is through the 'WLTE Control' app, available in app stores. This app allows for convenient parameter configuration and linking to Digital Output (DO) relays for complex automation control logic.

Screenshots of the 'WLTE Control' app interface, showing device adding, channel control, analog settings, timing manager, and general settings.
Figure 7.1: 'WLTE Control' APP Interface Overview
Screenshots of the 'WLTE Control' app showing device adding options (Scan QR, Manual Input) and channel control interfaces.
Figure 7.2: APP Instruction - Adding Device and Channel Control
More screenshots of the 'WLTE Control' app showing channel control, analog input settings, and general settings.
Figure 7.3: APP Instruction - Analog Input and Settings

7.1.1 Adding a Device

  1. Download and install the 'WLTE Control' app from your app market.
  2. Open the app and register/log in.
  3. Select 'Add device'. You can either 'Scan QR code' or 'Manual Input' the device details.
  4. Follow the on-screen prompts to complete device registration.

7.1.2 Channel Control

The app provides an interface to monitor analog inputs (AI) and control digital outputs (DO). You can toggle channels ON/OFF directly from the app.

7.1.3 Analog Input Configuration

To obtain accurate readings from connected analog sensors, you need to configure the analog input settings in the app:

  1. In the app, navigate to the analog input section (e.g., AI1, AI2, AI3, AI4).
  2. Long press on the analog input to enter its settings.
  3. Name Modification: Change the name of the analog input to reflect the connected sensor (e.g., "Wind Speed", "PT100", "Liquid Level", "Soil Temperature", "Soil Humidity").
  4. Analog Quantity Setting: Configure the parameters for the specific sensor:
    • Unit: Set the unit of measurement (e.g., °C, %, m, m/s).
    • Sensor Max/Min: Enter the maximum and minimum values the sensor can measure.
    • Analog Max/Min: Enter the maximum and minimum analog current values (typically 20 and 4 for 4-20mA sensors).
  5. Confirm the settings. Refresh the app to see the updated readings.

7.1.4 Advanced APP Features

Screenshots illustrating APP features like temperature control with alarms and timing control for up to 24 groups.
Figure 7.4: APP Features - Temperature Control and Timing
  • Temperature Control: Set a temperature threshold. When the detected temperature reaches this value, an alarm message can be sent, and a relay can be triggered.
  • Timing Control: Schedule up to 24 groups of timing tasks to turn devices ON/OFF daily or on specific days.
Screenshots showing APP features for power failure alert (GP4-WLTE-EC only), email pushing, and APP push notifications.
Figure 7.5: APP Features - Alerts and Notifications
  • Power Failure Alert (GP4-WLTE-EC only): Receive SMS/APP/Email alerts upon power failure and power restoration.
  • Email Pushing: Receive notification emails when a configured temperature or other parameter reaches a preset value.
  • APP Pushing: Get APP notifications to stay informed about device status.
Screenshots demonstrating Web control interface and short-time trigger switch function via the app for opening a garage door.
Figure 7.6: APP Features - Web Control and Trigger Switch
  • Short-time Trigger Switch: Configure a trigger time (1 to 1000 seconds) for momentary actions, such as opening a garage door.

7.2 SMS Control

You can control the device and receive alarms via SMS messages.

Image showing a smartphone with SMS messages for controlling devices like electric heaters, water pumps, and Ethernet switches.
Figure 7.7: SMS Control Interface

For example, you can send specific SMS commands to turn channels ON/OFF or query the status. SMS alarms can be configured to notify you when analog inputs reach certain thresholds (e.g., liquid level). Refer to the detailed SMS command list in the product documentation for specific commands.

7.3 Dial Control

The device can also be controlled by dialing specific numbers, allowing for simple ON/OFF control of connected devices.

Image illustrating dial control for devices such as electric heaters, water heaters, electric fans, and electric doors.
Figure 7.8: Dial Control Functionality

This method is useful for basic remote switching of appliances like electric heaters, water heaters, electric fans, or electric doors.

7.4 Web Control

The GP4-WLTE supports centralized control via a web browser on a PC, offering a comprehensive interface for managing your devices.

Screenshot of the web control interface on a laptop, showing channel status and administration options.
Figure 7.9: Web Control Interface

This allows for remote monitoring and control from any internet-connected device with a web browser.

7.5 Application Scenarios

Infographic showing various application scenarios for the GP4-WLTE controller, including agriculture, home appliance control, industrial applications, base station control, solar energy projects, and door openers.
Figure 7.10: Suitable Application Scenarios

The GP4-WLTE is suitable for a wide range of applications:

  • Agriculture: Pumped irrigation, seedling cultivation, aquatic products management.
  • Home Appliance Control: Remote control of household appliances.
  • Industrial Application: Equipment matching, efficiency improvement.
  • Base Station Control: Unattended remote control.
  • Solar Energy Project: Matching equipment, efficiency improvement.
  • Door Opener: Remote control of electric gates and rolling gates.
Diagram illustrating automatic pumping control using a liquid level sensor connected to GP4-WLTE, with PC and phone control interfaces.
Figure 7.11: Automatic Pumping Control Example
Showcase of solar greenhouse automation control using PT100, light, and soil sensors with GP4-WLTE for linkage roller blinds, irrigation, and ventilation fans, controlled via PC and phone.
Figure 7.12: Solar Greenhouse Automation Control Showcase

8. Maintenance

  • Regularly check all wiring connections to ensure they are secure.
  • Keep the device clean and free from dust and debris.
  • Ensure proper ventilation around the device to prevent overheating.
  • Periodically check for firmware updates through the app or manufacturer's website to ensure optimal performance and security.
  • If the device is exposed to harsh environmental conditions, inspect it more frequently for signs of wear or damage.

9. Troubleshooting

9.1 No Network Connection

  • Check if the SIM card is correctly inserted and activated.
  • Ensure the 4G antenna is securely connected.
  • Verify that the SIM card has an active data plan and sufficient balance.
  • Check the signal indicator (SIG LED) on the device. If it's not blinking or solid, there might be a network issue.
  • Confirm that the device is in an area with 2G/4G coverage.

9.2 Relays Not Responding

  • Check the power supply to the GP4-WLTE controller.
  • Verify the wiring of the relays to the controlled devices. Ensure COM, NO, and NC connections are correct.
  • Confirm that the control commands (APP, SMS, Web) are being sent correctly and are received by the device.
  • Check the relay indicator LEDs on the device to see if they are changing state.
  • Ensure the load connected to the relay is within its specified limits (10A@AC250V/DC30V). For high-power AC loads, confirm the AC contactor is correctly wired and functioning.

9.3 Incorrect Analog Readings

  • Verify the wiring of the analog sensor to the AI terminals (VCC, GND, AIx).
  • Ensure the sensor is a 4-20mA type and is functioning correctly.
  • Check the analog input configuration in the 'WLTE Control' app (Sensor Max/Min, Analog Max/Min, Unit). Incorrect settings will lead to inaccurate readings.
  • Ensure the sensor is properly calibrated.

9.4 APP/Web Control Issues

  • Ensure your smartphone or PC has an active internet connection.
  • Verify that the GP4-WLTE controller has a stable 4G network connection.
  • Check if the device is correctly added and online in the 'WLTE Control' app.
  • For web control, ensure the correct IP address or domain is used and that network firewalls are not blocking access.

10. User Tips

  • Analog Input Flexibility: While the device primarily supports 4-20mA analog input, it may be possible to adapt 0-5V or 0-10V sensors using external signal converters if needed. The app allows for custom unit adjustments, so you can configure it to display values in specific units like grams, meters, or percentages after proper sensor calibration.
  • Power Outage Alerts: For critical applications where power continuity is essential, consider using the GP4-WLTE-EC model, which includes a power failure alarm feature. This can provide timely notifications via SMS, APP, or email, allowing for quick response to power interruptions.
  • API Integration: If you have specific automation needs or want to integrate the GP4-WLTE into an existing system, leverage the provided TCP/HTTP API documentation for custom control and data retrieval.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.