MESTEK CM85C

Contents

Mestek CM85C AC/DC Clamp Meter Instruction Manual

Model: CM85C | Brand: MESTEK

1. Introduction

The Mestek CM85C is a compact and powerful AC/DC clamp meter designed for a wide range of electrical measurements. Its mini size and lightweight design make it highly portable, suitable for professional electricians and DIY enthusiasts alike. This manual provides detailed instructions for safe and effective use of your CM85C clamp meter.

Key Features:

  • AC/DC Current Measurement (up to 100A)
  • AC/DC Voltage Measurement (up to 600V)
  • Resistance Measurement (up to 20MΩ)
  • Capacitance Measurement (up to 2000uF)
  • Temperature Measurement (with K-type probe)
  • Diode Test
  • Continuity Test
  • NCV (Non-Contact Voltage) Detection
  • Auto Range Function
  • HD LCD with Backlight
  • Data Hold Function
  • Automatic Shutdown
  • Low Battery Reminder

2. Safety Information

Always observe basic safety precautions when using this instrument to avoid personal injury or damage to the meter or equipment under test. Read the following safety information carefully before use.

  • Do not exceed the maximum input values specified for each measurement function.
  • Do not use the meter if it or the test leads appear damaged.
  • Exercise extreme caution when working with voltages above 60V DC or 30V AC RMS, as these pose a shock hazard.
  • Always ensure the meter is in the correct function and range before making a measurement.
  • Disconnect power to the circuit and discharge all high-voltage capacitors before measuring resistance, continuity, diodes, or capacitance.
  • When measuring current with the clamp, ensure the circuit is de-energized before clamping around the conductor.
  • Replace the battery immediately when the low battery indicator appears to ensure accurate readings.

3. Product Overview

Familiarize yourself with the components of your Mestek CM85C clamp meter.

Diagram of Mestek CM85C clamp meter with labeled parts: Jaw, Trigger, Range switch, Monitor, Zero key, Function selection, Data hold/Backlight, COM and INPUT terminals.
Figure 3.1: CM85C Clamp Meter Components and Dimensions (165x56x31mm)

The meter features a jaw for non-contact current measurement, a trigger to open the jaw, a rotary range switch, an LCD monitor, and buttons for function selection (SEL), zeroing (Z), and data hold/backlight (H).

Mestek CM85C clamp meter shown with included test leads and temperature probe.
Figure 3.2: CM85C Clamp Meter with Test Leads and Temperature Probe

4. Setup

4.1 Battery Installation

The Mestek CM85C requires 2 x 1.5V AAA batteries (not included). To install or replace batteries:

  1. Ensure the meter is turned OFF.
  2. Locate the battery compartment on the back of the meter.
  3. Use a screwdriver to open the battery compartment cover.
  4. Insert two AAA batteries, observing the correct polarity (+/-).
  5. Replace the battery compartment cover and secure it with the screw.

4.2 Connecting Test Leads and Temperature Probe

For voltage, resistance, capacitance, diode, and continuity measurements, connect the test leads. For temperature measurements, connect the K-type temperature probe.

  • Insert the red test lead into the 'INPUT' terminal.
  • Insert the black test lead into the 'COM' terminal.
  • For temperature measurement, connect the K-type probe to the 'INPUT' and 'COM' terminals, ensuring correct polarity if applicable (refer to probe markings).

5. Operating Instructions

The CM85C features an auto-ranging function, simplifying operation by automatically recognizing the measurement range. Use the rotary switch to select the desired function.

Video 5.1: Demonstration of Mestek CM85C features including ambient temperature, DC/AC voltage switch, continuity/capacitance/resistance, different current ranges, NCV voltage detection, and backlight.

5.1 General Operation

  1. Power On/Off: Rotate the central dial from 'OFF' to any measurement function to power on. Rotate back to 'OFF' to power off.
  2. Auto Range: The meter automatically selects the appropriate range for most measurements. No need to manually switch ranges.
  3. Data Hold (H button): Press the 'H' button to freeze the current reading on the display. Press again to release.
  4. Backlight (H button long press): Long press the 'H' button to turn the LCD backlight on or off for improved visibility in low-light conditions.
  5. Zero (Z button): Used to zero out readings, particularly for DC current measurements to eliminate residual magnetic fields.
  6. Automatic Shutdown: The meter will automatically power off after a period of inactivity to conserve battery life.

5.2 AC/DC Current Measurement (Clamp)

Use the clamp jaw for non-contact current measurement. The large jaws can open up to 25mm.

  1. Rotate the dial to the 'A~' (AC Current) or 'A=' (DC Current) position.
  2. Press the trigger to open the clamp jaw.
  3. Enclose a single conductor (not a bundle of wires) within the clamp jaw.
  4. Release the trigger to close the jaw. The current reading will be displayed.
Mestek CM85C clamp meter measuring DC current in a car battery cable.
Figure 5.2: Auto DC Current Measurement
Mestek CM85C clamp meter measuring AC current in a household electrical panel.
Figure 5.3: AC Current Measurement
Close-up of the clamp meter's jaw, showing it can open up to 25mm for various wire measurements.
Figure 5.4: Clamp Jaw Opening (25mm)

5.3 DC/AC Voltage Measurement

  1. Connect the test leads to the 'INPUT' and 'COM' terminals.
  2. Rotate the dial to the 'V~' (AC Voltage) or 'V=' (DC Voltage) position. Use the 'SEL' button to switch between AC and DC if needed.
  3. Touch the test probes to the circuit points where you want to measure voltage.
  4. The voltage reading will be displayed on the LCD.
Four images showing the clamp meter performing various tests: DC voltage, AC voltage, capacitance detection, and resistance measurement.
Figure 5.5: Examples of DC Voltage, AC Voltage, Capacitance, and Resistance Measurements

5.4 Resistance, Capacitance, Diode, and Continuity Measurement

  1. Connect the test leads to the 'INPUT' and 'COM' terminals.
  2. Rotate the dial to the 'Ω' (Resistance), 'F' (Capacitance), or 'Diode/Continuity' position.
  3. Use the 'SEL' button to cycle through Resistance, Capacitance, Diode, and Continuity functions if they share a single dial position.
  4. Touch the test probes to the component or circuit under test.
  5. The measurement will be displayed. For continuity, an audible beep indicates a continuous circuit.

5.5 Temperature Measurement

  1. Connect the K-type temperature probe to the 'INPUT' and 'COM' terminals.
  2. Rotate the dial to the '°C/°F' position.
  3. Place the tip of the temperature probe on or in the object whose temperature you wish to measure.
  4. The temperature reading will be displayed. Press the 'SEL' key to switch between Celsius (°C) and Fahrenheit (°F).
Mestek CM85C clamp meter measuring the temperature of water in a glass using the K-type temperature probe.
Figure 5.6: Temperature Measurement

5.6 NCV (Non-Contact Voltage) Detection

The NCV function allows for detection of AC voltage without direct contact, enhancing safety.

  1. Rotate the dial to the 'NCV' position.
  2. Gradually approach the NCV probe (top of the meter) to the detected point (e.g., an electrical outlet or wire).
  3. If AC voltage is detected, the instrument will automatically send out an alarm prompt (audible and/or visual).
Mestek CM85C clamp meter performing NCV detection on a power strip, showing a red alert icon indicating voltage detection.
Figure 5.7: NCV Non-Contact Induction

6. Maintenance

6.1 Cleaning

Wipe the meter with a damp cloth and mild detergent. Do not use abrasives or solvents. Keep the terminals free from dirt and moisture.

6.2 Storage

When not in use for an extended period, remove the batteries to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.

7. Troubleshooting

  • No display/Meter won't turn on: Check battery installation and ensure batteries are not depleted. Replace if necessary.
  • 'OL' (Overload) displayed: The measured value exceeds the selected range. The auto-range function should handle this, but if it persists, the value might be beyond the meter's maximum capacity.
  • Inaccurate readings: Ensure test leads are properly connected. Check battery level. Ensure the correct function is selected. For current measurements, make sure only one conductor is within the clamp jaw.

8. Specifications

FunctionRangeAccuracyResolution
AC Current0.001A~100A±(2.5%+6)0.001A~0.1A
DC Current0.001A~100A±(2.5%+6)0.001A~0.1A
DC Voltage0.001V~600V±(0.5%+3)0.001V~0.1V
AC Voltage0.001V~600V±(1.0%+3)0.001V~0.1V
Resistance1Ω~20MΩ±(0.8%+3)0.1Ω~0.01MΩ
Capacitance1nF~2000uF±(3.5%+15)0.1nF~0.001uF
DiodeYes--
ContinuityYes--
NCV InductionYes--
Data HoldYes--
BacklightYes--
K-type ProbeYes--
Maximum Display1999 counts--
Operating Temperature0~40 °C--
Dimensions165*56*31mm--
Weight140g--
Battery1.5V AAA*2 (not included)--
Technical index table showing functions, ranges, accuracy, and resolution for AC/DC current, voltage, resistance, and capacitance, along with other features.
Figure 8.1: Technical Specifications

9. Product Accessories

The following items are typically included with your Mestek CM85C clamp meter:

  • Mestek CM85C Clamp Meter
  • Test Leads (Red and Black)
  • K-type Temperature Probe
  • User Manual
  • Storage Bag
  • Packing Box
Image showing the Mestek CM85C clamp meter, test leads, temperature probe, user manual, and storage bag.
Figure 9.1: Product Accessories

10. User Tips

  • Small DC Current Measurement: While the meter is capable of DC current measurement, some users have reported that it may not provide highly accurate readings for very small DC currents (in the milliampere range). For critical applications requiring precise small DC current measurements, consider using a dedicated milliampere meter or verifying readings with a known accurate device.
  • Clamping Technique: Always ensure the clamp jaw completely encloses only one conductor for accurate current readings. Clamping around multiple conductors (e.g., a power cord with both live and neutral wires) will result in a zero or incorrect reading as the magnetic fields cancel each other out.
  • Temperature Probe Care: The K-type temperature probe is delicate. Avoid bending or stressing the probe tip excessively to prevent damage.

11. Warranty and Support

MESTEK products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official MESTEK website. Keep your purchase receipt as proof of purchase for any warranty claims.