SUSWE SU300 / HSD3000 Series

Contents

SUSWE Variable Frequency Drive (VFD) Inverter Instruction Manual

Model: SU300 / HSD3000 Series

Brand: SUSWE

1. Introduction

This manual provides detailed instructions for the safe and effective installation, operation, and maintenance of your SUSWE Variable Frequency Drive (VFD) Inverter. This high-performance vector converter is designed for precise speed control of three-phase motors, offering stable quality, reduced energy loss, and excellent low-frequency torque.

Key features include:

  • High performance vector control
  • Stable quality and reliable operation
  • Reduced energy loss
  • Excellent low frequency and large torque output
  • Quality assurance with a 1-year warranty
  • Support for remote debugging guidance
SUSWE VFD Inverter highlighting key features

Image: Front view of the SUSWE VFD Inverter, showcasing its main features and benefits.

2. Specifications

The SUSWE VFD Inverter is a versatile device available in various power ratings and voltage configurations. Below are the general specifications and a detailed model-specific table.

General Specifications:

  • Type: DC/AC Inverter (Variable Frequency Drive)
  • Output Frequency: 50/60Hz (General), 0.1-400Hz (Adjustable)
  • Output Power: 500 - 1000W (General), 750W - 5500W (Model Dependent)
  • Output Type: Three-phase
  • Origin: Mainland China
  • Certification: CE, RoHS
  • Output Frequency Range: Low frequency mode: 0-600Hz; High frequency mode: 0-3000Hz

Dimensions:

The physical dimensions of the inverter are approximately:

  • Width: 9.5 cm
  • Height: 18.0 cm
  • Depth: 11.3 cm
Dimensions of the VFD Inverter

Image: Diagram showing the dimensions of the VFD Inverter.

Model-Specific Parameters:

Refer to the table below for detailed voltage, output current, and power specifications for each model.

Table of VFD Inverter Model Specifications

Image: Table detailing model, voltage level, output current, and power for various VFD models.

Inverter Voltage Description:

  • 220V: Input single-phase 220V, output three-phase 220V
  • 380V: Input three-phase 380V, output three-phase 380V

3. Safety Instructions

Please read and understand all safety instructions before installing, operating, or maintaining the VFD inverter. Failure to comply with these instructions may result in personal injury or equipment damage.

  • **Electrical Hazard:** This device operates with high voltage. Only qualified personnel should perform installation and maintenance.
  • **Residual Voltage:** The VFD inverter contains capacitors that can retain a dangerous charge even after the power supply is disconnected. Observe the "DANGER 5 min" warning on the unit. Always wait at least 5 minutes after disconnecting power before touching any internal components or terminals.
  • **Proper Grounding:** Ensure the inverter is properly grounded according to local electrical codes.
  • **Environmental Conditions:** Install the inverter in a clean, dry, and well-ventilated area, away from direct sunlight, excessive dust, corrosive gases, and flammable materials.
  • **Emergency Stop:** Familiarize yourself with the emergency stop procedures for your motor system.

Protection Functions:

The VFD inverter is equipped with six essential protection functions to ensure safe and reliable operation:

  1. Overcurrent protection
  2. Overvoltage protection
  3. Undervoltage protection
  4. Overload protection
  5. Power module protection
  6. Overtemperature protection
Diagram of Six Protection Functions

Image: Visual representation of the six built-in protection functions.

4. Installation

Proper installation is crucial for the performance and longevity of your VFD inverter. Follow these guidelines carefully.

Mounting:

The VFD inverter supports guide rail one-button installation for ease of setup.

Guide Rail One-Button Installation

Image: Illustration of the guide rail mounting mechanism for quick installation.

Wiring Diagrams:

Ensure all wiring is performed by a qualified electrician and complies with local electrical codes.

Main Power Terminal Connection:

Connect the input power supply to the R, S, T terminals for three-phase input, or L1, L2 for single-phase input. Connect the motor to the U, V, W output terminals. A braking resistor can be connected to P+ and PB terminals if the brake function is required.

Single-phase and Three-phase Power Supply Wiring Diagrams

Image: Detailed wiring diagrams for both single-phase and three-phase power supply connections, including braking resistance and motor output.

Main Line Terminal Connection Diagram

Image: Diagram showing the connection of the input three-phase 380V to R/S/T terminals.

Braking Resistor and Motor Output Wiring

Image: Diagram illustrating the connection of the braking resistor to P+PB and the motor to UVW output terminals.

Control Terminal Connection:

The VFD provides various control terminals for external signals and communication. These include digital inputs (J1, J2, J3), analog inputs (AO, AI), and RS485 communication terminals.

Control Terminal Connection Diagram

Image: Diagram showing the layout and connections for control terminals including ROA, ROC, 24V, S1, S2, S3, S5/Y, GND, AI, AO, 10V, 485+, and 485-.

External Start/Stop Button Wiring

Image: Wiring diagram for connecting external start (DI1) and stop (DI2) buttons to the VFD's control terminals.

External Control Panel:

An optional external control panel with a cable is available for remote operation. Please note that this external panel is specifically designed for the SU300 frequency converter purchased from our store and is not compatible with VFDs from other manufacturers.

External Control Panel and Cable

Image: The external control panel and its connecting cable.

5. Operation

The VFD inverter features a user-friendly control panel for easy operation and monitoring.

Control Panel Overview:

The classic layout control panel provides human-computer interactive ergonomic design with clearly labeled buttons and a digital display.

VFD Control Panel Layout

Image: Labeled diagram of the VFD control panel, showing display, PRG, M-FUN, Speed control knob, Decrement, Increment, Run, Shift, Stop, and Confirm buttons.

The smart display provides clear working information, including current, voltage, power factor, motor temperature, and operation time.

Smart Display of VFD

Image: Close-up of the VFD's smart display showing operational data.

Basic Operation Steps:

Follow these steps for basic motor speed control:

  1. **Power On:** Turn on the main power switch to supply three-phase 380V (or appropriate voltage) to the inverter.
  2. **Start Operation:** Press the RUN key to start the operation of the converter.
  3. **Adjust Speed:** Turn the speed control knob (potentiometer) to adjust the rotation speed of the motor. Turning clockwise increases speed, counter-clockwise decreases speed.
  4. **Stop Operation:** Press the STOP/REST button to slowly stop the motor.
  5. **Power Off:** Pull down the main power switch to completely power off the system.

Video: Demonstration of basic VFD operation, including power-on, starting, speed adjustment, and stopping the motor.

Advanced Functions:

The VFD inverter offers several advanced functions for versatile applications:

  • **Multi-segment operation:** 16-segment programmable multi-speed control with multiple operation modes.
  • **Simple PLC operation:** Up to 16 sections of speed can be set, with adjustable operation time for each section.
  • **RS485 communication:** Multiple communication protocols can be selected for linkage synchronization control.
  • **Output frequency range:** Wide range, from 0-600Hz in low frequency mode to 0-3000Hz in high frequency mode.
  • **PID control:** Widely used in constant pressure water supply, wind pressure constant pressure control, and other applications.
  • **Built-in brake unit:** For models 0.75KW-18.5KW, the brake unit is built-in and does not need to be purchased separately.
Diagram of Six Advanced Functions

Image: Overview of the six advanced functions and their capabilities.

6. User Tips

  • **Power Reserve:** When selecting a VFD, it is generally recommended to choose a model with a suitable power reserve relative to your electric motor's rating for optimal performance and longevity.
  • **External Panel Compatibility:** If using an external control panel, ensure it is specifically designed for the SU300 series from our store, as compatibility with other brands is not guaranteed.
  • **Detailed Parameter Settings:** For advanced configurations and specific parameter adjustments, refer to the full product manual or contact technical support.

7. Maintenance

Regular maintenance helps ensure the long-term reliability and performance of your VFD inverter.

  • **Cleaning:** Keep the inverter clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
  • **Ventilation:** Ensure proper airflow around the unit. The VFD features a silent fan for effective heat dissipation. Regularly check that the fan is operating correctly and not obstructed.
  • **Connections:** Periodically check all electrical connections for tightness and signs of corrosion.
  • **Environmental Check:** Ensure the operating environment remains within specified temperature and humidity ranges.
Silent Fan Feature

Image: Highlighting the silent fan for efficient cooling and reduced noise.

8. Troubleshooting

This section addresses common issues you might encounter. For more complex problems, please contact technical support.

ProblemPossible CauseSolution
Inverter does not power onNo input power, incorrect wiring, blown fuse.Check power supply, verify wiring, inspect fuses.
Motor does not runRUN command not issued, motor wiring incorrect, VFD fault (e.g., overcurrent, overload).Press RUN, check motor connections, check VFD display for fault codes.
Motor speed is unstableIncorrect parameter settings, motor load fluctuations, poor wiring.Review parameter settings (e.g., PID control), ensure stable load, check wiring integrity.
"DANGER 5 min" warningResidual voltage present after power-off.Wait at least 5 minutes after disconnecting power before touching any components.

For detailed fault codes and advanced troubleshooting, please consult the comprehensive product manual or contact our technical support team.

9. Warranty and Support

Your SUSWE VFD Inverter comes with a **1-year warranty** from the date of purchase, covering manufacturing defects and malfunctions under normal operating conditions.

For technical assistance, debugging guidance, or warranty claims, please contact our support team. We offer 24-hour one-to-one debugging guidance and remote package debugging services to ensure your system operates smoothly.

Contact Information: [Please refer to your purchase documentation or the seller's store page for specific contact details.]

10. Frequently Asked Questions (FAQ)

Q: What does "Danger 5 min" on the panel mean?
A: This warning indicates that residual voltage may be present in the inverter's capacitors for up to 5 minutes after the power supply has been disconnected. It is crucial to wait this duration before performing any maintenance, inspection, or touching internal components to avoid electric shock.
Q: Is the external control panel compatible with VFDs from other manufacturers?
A: No, the external control panel (if purchased separately) is specifically designed for the SUSWE SU300 series frequency converters. Compatibility with VFDs produced by other manufacturers is not guaranteed.
Q: Can this inverter convert 220V single-phase to 380V three-phase?
A: The available models support either 220V single-phase input to 220V three-phase output, or 380V three-phase input to 380V three-phase output. Please refer to the "Model-Specific Parameters" table in the Specifications section to select the correct model for your voltage requirements.
Q: What should be the power reserve of the frequency converter to the electric motor?
A: It is generally recommended to select a VFD with a power rating equal to or slightly higher than your motor's rated power. This provides a suitable power reserve for optimal performance, especially under varying load conditions, and helps extend the lifespan of both the VFD and the motor. For precise sizing, consult a qualified electrical engineer or refer to detailed application guides.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.