SUSWE SU300 Series Frequency Inverter

Contents

SUSWE SU300 Series VFD Frequency Inverter Instruction Manual

Model: SU300 Series | Brand: SUSWE

1. Introduction

This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the SUSWE SU300 Series VFD (Variable Frequency Drive) Frequency Inverter. This device is designed to control the speed and torque of three-phase AC motors by varying the frequency and voltage of the power supplied to the motor. It supports both single-phase and three-phase input voltages, providing a three-phase output.

Please read this manual thoroughly before installation and operation to ensure safe and efficient use of the product.

2. Safety Information

WARNING: Electrical shock hazard. Only qualified personnel should perform installation and maintenance.

  • Always disconnect power before working on the inverter or motor.
  • Ensure proper grounding of the inverter and motor.
  • Do not touch electrical components when power is applied.
  • Verify correct wiring connections according to the diagrams provided in this manual.
  • Install the inverter in a well-ventilated area, away from direct sunlight, moisture, and corrosive gases.
  • Do not operate the inverter with damaged cables or if the casing is open.
  • Refer to local electrical codes and regulations for installation.

3. Key Features

  • High Performance Vector Control: Advanced vector control technology for precise motor speed and torque regulation.
  • Wide Power Range: Available for motors from 0.75KW to 5.5KW.
  • Flexible Input/Output: Supports single-phase 220V input to three-phase 220V output, and three-phase 380V input to three-phase 380V output.
  • Adjustable Output Frequency: Range from 0.1Hz to 400Hz.
  • Multiple Control Modes: Includes multi-segment operation, simple PLC operation, and PID control.
  • Communication Interface: RS485 communication for integration with other systems.
  • Built-in Brake Unit: Integrated brake unit for models from 0.75KW to 18.5KW, eliminating the need for a separate purchase.
  • Silent Operation: Equipped with a DC powerful radiator and intelligent start/stop control for reduced noise and heat.
  • Smart Display: Clear display of working information including current, voltage, power factor, motor temperature, and operation time.
  • Robust Protection Functions: Comprehensive protection against overcurrent, overvoltage, undervoltage, overload, power module faults, and overtemperature.
  • Easy Installation: Features guide rail one-button installation for convenience.
  • Quality Assurance: Designed for stable quality, reduced loss, and strong parameter stability.

4. Specifications

Product parameters table for various VFD models

Table: Detailed product parameters for various SU300 series models.

General Specifications
ParameterValue
Brand NameSUSWE
TypeAC Frequency Converter (Vector Universal Frequency Converter)
Input VoltageSingle-phase 220V / Three-phase 380V
Output VoltageThree-phase 220V / Three-phase 380V
Output Frequency0.1 - 400 Hz (Adjustable)
Output Power Range0.75KW - 5.5KW
Dimensions (L x W x H)Approx. 142mm x 85mm x 116.35mm (Specific dimensions may vary by model)
Weight1 - 1.5 KG (Approximate)
CertificationCE, RoHS
OriginMainland China

Inverter Voltage Description:

  • 220V: Input single-phase 220V, output three-phase 220V.
  • 380V: Input three-phase 380V, output three-phase 380V.

5. Package Contents

Upon opening the package, please verify that all items are present and undamaged:

  • Frequency Converter Unit (x1)
  • English Instruction Manual (x1)

6. Installation

6.1 Mounting

The SU300 series VFD supports guide rail one-button installation for easy mounting.

Guide rail one-button installation top view

Figure 6.1: Guide rail one-button installation (top view).

Guide rail one-button installation side view

Figure 6.2: Guide rail one-button installation (side view).

6.2 Wiring

Ensure all power is disconnected before performing any wiring. Refer to the following diagrams for correct connections.

6.2.1 Power Supply and Motor Wiring

Single-phase and Three-phase power supply wiring diagrams

Figure 6.3: Single-phase and Three-phase power supply wiring diagrams. L1, L2 for single-phase input; R, S, T for three-phase input. U, V, W for three-phase motor output. PE for protective earth.

Input Connections:

  • Single-phase 220V Input: Connect to terminals L1 and L2.
  • Three-phase 380V Input: Connect to terminals R, S, and T.

Output Connections:

  • Motor Output: Connect the three-phase motor to terminals U, V, and W.
Main line terminal connection diagram for R/S/T input

Figure 6.4: Main line terminal connection diagram showing input three-phase 380V connected to R/S/T terminals.

6.2.2 Braking Resistor Connection

For applications requiring braking, connect a braking resistor to the P+ and PB terminals. Ensure the brake function is fully installed and configured.

Braking resistor and motor output connections

Figure 6.5: P+PB terminals for braking resistor connection and UVW terminals for motor output.

6.2.3 Control Terminal Wiring

The inverter provides various control terminals for external control signals and communication.

Control terminal wiring diagram

Figure 6.6: Example control terminal wiring for start/stop buttons (DI1, DI2).

Common control terminals include:

  • Digital Inputs (DI): S1, S2, S3, S5/Y, DI1, DI2, DI3, DI4, DI5 (for start, stop, multi-speed, etc.)
  • Analog Inputs (AI): AI (voltage/current input for speed reference)
  • Analog Outputs (AO): AO (voltage/current output for monitoring)
  • Communication: 485+, 485- (for RS485 communication)
  • Power Supply: 24V, 10V, GND
  • Relay Outputs: ROA, ROC (for status indication)

Refer to the detailed wiring diagram for specific terminal functions and connections.

7. Operation

7.1 Control Panel Overview

The inverter features a user-friendly control panel for monitoring and parameter adjustment.

Control panel layout with button labels

Figure 7.1: Control panel layout. Key functions include: Display, PRG (Program), M-FUN (Multifunction Selection), Speed control knob, Decrement, Increment, Shift, Run, Enter, Stop/Rest, Confirm.

7.2 Basic Operation (Start, Speed Adjustment, Stop)

The following video demonstrates the basic operation of the VFD with a motor:

Video 7.1: Demonstration of VFD power-on, motor start, speed adjustment using the knob, and motor stop.

  1. Power On: Turn on the main power switch to the inverter. The display will light up.
  2. Start Operation: Press the RUN key on the control panel to start the motor.
  3. Adjust Speed: Turn the speed control knob (potentiometer) to adjust the rotation speed of the motor. The display will show the current frequency/speed.
  4. Slow Down: Turn the speed control knob counter-clockwise to decrease the motor speed.
  5. Stop Operation: Press the STOP/REST button to slowly stop the motor.
  6. Power Off: Once the motor has come to a complete stop, pull down the main power switch to disconnect power.

7.3 Advanced Functions

The SU300 series VFD offers several advanced functions for complex applications:

  • Multi-segment Operation: Configure up to 16 segments of programmable multi-speed control with optional multiple operation modes.
  • Simple PLC Operation: Set operation time for up to 16 sections.
  • RS485 Communication: Select multiple communication protocols with linkage synchronization control function.
  • Output Frequency Range: Wide range from 0-600Hz in low frequency mode and 0-3000Hz in high frequency mode.
  • PID Control: Widely used in constant pressure water supply, wind pressure constant pressure control, and other applications.

8. User Tips

  • Wiring Clarity: When connecting, pay close attention to the input phase (single-phase or three-phase) and ensure the correct terminals (L1/L2 or R/S/T) are used. The output to the motor is always U/V/W.
  • Output Frequency: The inverter allows for a wide adjustable output frequency range (0.1-400Hz). This is different from the standard 50/60Hz utility frequency. Adjust the speed control knob or program parameters to achieve the desired output frequency for your motor.
  • External Panel: If you require an external control panel, ensure it is specifically designed for SU300 frequency converters and purchased from a compatible source.

9. Troubleshooting

The SU300 series VFD is equipped with six protection functions to ensure safe operation. If an issue occurs, the inverter's display may show an error code or the motor may behave unexpectedly. Refer to the following common protection functions:

Six protection functions diagram

Figure 9.1: Diagram illustrating the six protection functions of the VFD.

  • Overcurrent Protection: Triggered if the output current exceeds a safe limit. Check for motor overload, short circuits in motor wiring, or incorrect motor parameters.
  • Overvoltage Protection: Activated if the DC bus voltage exceeds a safe level, often due to regenerative braking or unstable input voltage.
  • Undervoltage Protection: Occurs if the input voltage drops below the minimum operating threshold. Check the power supply.
  • Overload Protection: Protects the motor and inverter from sustained excessive load. Reduce the motor load or check motor parameters.
  • Power Module Protection: Indicates an internal fault within the inverter's power module. This typically requires professional service.
  • Overtemperature Protection: Engages if the inverter's internal temperature exceeds safe limits. Check for proper ventilation, ensure the silent fan is operating, and clear any obstructions.

For detailed error codes and specific troubleshooting steps, please consult the full English manual included with your product.

10. Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your VFD Frequency Inverter.

  • Cleaning: Periodically clean the exterior of the inverter to prevent dust accumulation, especially around ventilation openings. Use a soft, dry cloth. Do not use liquid cleaners.
  • Fan Inspection: The inverter features a silent fan for cooling. Regularly check that the fan is free from obstructions and operating correctly. A clogged fan can lead to overheating and trigger overtemperature protection.
  • Terminal Connections: Periodically inspect all wiring terminals to ensure they are tight and free from corrosion. Loose connections can cause intermittent operation or damage.
  • Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges. Avoid exposure to excessive dust, moisture, or corrosive substances.

11. Warranty and Support

The SUSWE SU300 Series VFD Frequency Inverter comes with a 1-year warranty from the date of purchase, covering manufacturing defects.

For technical assistance, troubleshooting beyond the scope of this manual, or warranty claims, please contact the seller or manufacturer's support team. Remote package debugging guidance may be available to assist with complex issues.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.