SUSWE VFD (Variable Frequency Drive) SU300 / HSD3000 Series Instruction Manual

Models: 0.75KW - 5.5KW

Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SUSWE VFD (Variable Frequency Drive) SU300 / HSD3000 Series. This VFD is designed to control the speed of AC motors, offering high performance and reliability. Please read this manual thoroughly before attempting to install or operate the device.

SUSWE VFD showing power input/output options

Figure 1: SUSWE VFD with input/output voltage options (220V 1PH Input / 220V 3PH Output OR 380V 3PH Input / 380V 3PH Output)

Safety Information

WARNING: Electrical Hazard. Improper installation or operation can lead to serious injury or death. Only qualified personnel should perform installation and maintenance.

  • Always disconnect power before working on the VFD or connected equipment.
  • Ensure proper grounding of the VFD and motor.
  • Do not touch electrical components immediately after power-off. The VFD may retain high voltage for several minutes. Observe the 'DANGER 5 min' warning on the unit.
  • Protect the VFD from moisture, dust, and corrosive gases.
  • Ensure adequate ventilation to prevent overheating.

Product Overview

Key Features

  • Low repair rate due to imported parts.
  • Compact design to reduce product volume and save space.
  • Easy installation and wiring.
  • Strong parameter stability and user-friendly operation.
  • High-function universal vector control.
  • Powerful radiator for efficient cooling.
  • Environmental protection features.
  • Fast response and high control accuracy.
  • Energy-saving capabilities.
  • Simple and convenient wiring.
  • Excellent stable frequency moment output.
  • Built-in brake unit (for 0.75KW-18.5KW models, no separate purchase needed).
Product advantages of the VFD

Figure 2: Product Advantages

Control Panel

The VFD features a classic layout control panel with a smart display and quick keys for easy human-computer interaction.

VFD control panel layout with button labels

Figure 3: Control Panel Layout

  • Display: Shows current operating parameters (frequency, voltage, current, etc.).
  • PRG (Program): Enters/exits parameter setting mode.
  • M-FUN (Multi-function): Selects multi-function parameters.
  • Speed control knob: Adjusts the output frequency/motor speed.
  • Decrement (Down Arrow): Decreases parameter values or navigates menus.
  • Increment (Up Arrow): Increases parameter values or navigates menus.
  • SHIFT (Double Arrow): Shifts cursor position during parameter editing.
  • RUN (Green Button): Starts motor operation.
  • ENTER: Confirms parameter settings or menu selections.
  • STOP/REST (Red Button): Stops motor operation or resets faults.

Specifications

General Specifications

  • Output Frequency: 0.1-400HZ
  • Output Power: 750W-5500W
  • Type: AC Frequency Converter (DC/AC Inverter)
  • Origin: Mainland China
  • Certification: CE, RoHS
  • High-concerned chemical: None
  • is_customized: None
  • Output Type: SINGLE

Model Parameters

Table of VFD model parameters including voltage, current, and power

Figure 4: Product Parameters Table

VFD Model Specifications
ModelVoltage Level (V)Output Current (A)Power (KW)
HSD3000-0R7G-T4220 (V)4 (A)0.75 (KW)
HSD3000-1R5G-T4220 (V)7 (A)1.5 (KW)
HSD3000-2R2G-T4220 (V)11 (A)2.2 (KW)
HSD3000-0R7G-T4380 (V)2.1 (A)0.75 (KW)
HSD3000-1R5G-T4380 (V)3.8 (A)1.5 (KW)
HSD3000-2R5G-T4380 (V)5.1 (A)2.2 (KW)
HSD3000-0R3G-T4380 (V)6.8 (A)3 (KW)
HSD3000-0R4G-T4380 (V)9 (A)4 (KW)
HSD3000-5R5G-T4380 (V)13 (A)5.5 (KW)

Inverter Voltage Description:

  • 220V: Input single-phase 220V, output three-phase 220V
  • 380V: Input three-phase 380V, output three-phase 380V

Dimensions

VFD dimensions: 9.5 cm width, 18.0 cm height, 11.3 cm depth

Figure 5: Product Dimensions (Approx. 9.5 cm W x 18.0 cm H x 11.3 cm D)

Installation

Mounting

The VFD supports guide rail one-button installation for convenient setup.

Guide rail mounting mechanism for VFD

Figure 6: Guide Rail Installation

Wiring Diagrams

Ensure all wiring is performed by a qualified electrician and adheres to local electrical codes.

Wiring diagram for single-phase and three-phase power supply, and control terminals

Figure 7: Power and Control Terminal Wiring Diagram

Main Line Terminal Connection:

Main line terminal connection diagram for 380V three-phase input

Figure 8: Main Line Terminal Connection (Input three-phase 380V connected to R/S/T)

Motor Output and Braking Resistor Connection:

Motor output UVW and braking resistor P+PB connection

Figure 9: Motor Output (UVW) and Braking Resistor (P+PB) Connection. Use the brake function to fully install the braking resistor.

Control Terminal Wiring Example (Start/Stop Buttons):

Control terminal wiring diagram with start and stop buttons

Figure 10: Control Terminal Wiring for Start (DI1) and Stop (DI2) Buttons

Operation

Basic Operation

The VFD allows for precise control of motor speed and direction. Refer to the control panel diagram (Figure 3) for button functions.

Video 1: Basic VFD Operation Demonstration (Power on, Run, Speed Adjustment, Stop, Power off)

  1. Power On: Turn on the main power switch to the VFD. The display will light up.
  2. Start Motor: Press the RUN button to start the motor.
  3. Adjust Speed: Turn the speed control knob (potentiometer) to adjust the rotation speed of the motor. The display will show the current frequency.
  4. Slow Down: Turn the speed control knob counter-clockwise to decrease motor speed.
  5. Stop Motor: Press the STOP/REST button to gradually stop the motor.
  6. Power Off: Once the motor has completely stopped, pull down the main power switch.

Advanced Functions

The VFD offers several advanced operational modes and communication protocols:

  • Multi-segment operation: 16-segment programmable multi-speed control with multiple operation modes.
  • Simple PLC operation: Up to 16 sections of speed can be set, with adjustable operation time for each section.
  • RS485 communication: Multiple communication protocols can be selected with linkage synchronization control function.
  • Output frequency range: Wide range, low frequency mode: 0-600Hz; High frequency mode: 0-3000Hz.
  • PID control: Widely used in constant pressure water supply, wind pressure constant pressure control, and other applications.
Diagram illustrating 6 functions for outstanding performance

Figure 11: Advanced Functions Overview

Maintenance

Regular maintenance ensures the longevity and optimal performance of your VFD.

  • Cleaning: Keep the VFD clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquids or abrasive cleaners.
  • Cooling Fan: The VFD is equipped with a silent fan and a powerful radiator to dissipate heat. Ensure the fan vents are not obstructed. Periodically check the fan for proper operation and clean any accumulated dust.
  • Connections: Periodically check all electrical connections for tightness and signs of corrosion.
  • Environment: Ensure the operating environment remains within specified temperature and humidity ranges.
Image highlighting the silent cooling fan of the VFD

Figure 12: Silent Cooling Fan

Troubleshooting

The VFD is equipped with six protection functions to ensure safe operation. If an issue occurs, the VFD may display an error code or stop operation. Consult the full product manual for specific error codes and their remedies.

Protection Functions

Diagram showing six protection functions: Overcurrent, Overvoltage, Undervoltage, Overload, Power module protection, Overtemperature protection

Figure 13: Six Protection Functions

  • Overcurrent Protection: Occurs when the output current exceeds a safe limit. Check for motor overload or short circuits.
  • Overvoltage Protection: Triggered by excessive DC bus voltage. Check input voltage and braking resistor if used.
  • Undervoltage Protection: Occurs when the DC bus voltage drops below a safe level. Check input power supply.
  • Overload Protection: Activated when the motor or VFD is continuously operating above its rated capacity. Reduce load or check motor sizing.
  • Power Module Protection: Indicates an issue with the internal power components. Contact support if this fault persists.
  • Overtemperature Protection: Occurs when the VFD's internal temperature is too high. Check for blocked ventilation, high ambient temperature, or fan malfunction.

User Tips

  • Cooling Fan Operation: The cooling fan on some VFD models may run continuously, while on others it may only activate when the VFD is actively running or when internal temperatures rise. This is normal behavior to ensure proper cooling.
  • External Control Panel: If you require an external control panel for your SU300 series VFD, ensure it is specifically designed for compatibility with this model.
  • Language: The included manual is in English. For additional language support or detailed parameter settings, please refer to the manufacturer's official website or contact customer support.

Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt and product model information handy when contacting support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.