1. Introduction
This manual provides essential information for the safe and efficient operation of your Kamoer NKP Peristaltic Dosing Pump. Please read it thoroughly before use and retain it for future reference.

Image: A set of Kamoer NKP Peristaltic Dosing Pumps in black, yellow, green, and blue, indicating a 3-in-pack.
2. Safety Information
- Ensure the pump is connected to the correct voltage supply (6V, 12V, or 24V) as specified for your model.
- Do not operate the pump with damaged power cables or tubing.
- Keep the pump away from excessive heat, moisture, and corrosive environments.
- Always disconnect power before performing any maintenance or tube changes.
- This pump is designed for transferring liquids. Ensure the liquid is compatible with the chosen tube material (Silicone or BPT).
3. Specifications
General Parameters
| Parameter | Detail |
|---|---|
| Application | Metering |
| Theory | Peristaltic pump |
| Structure | Peristaltic Pump |
| Model Number | New KP |
| Standard or Nonstandard | Standard |
| Pressure | Low Pressure |
| Origin | CHINA |
| Certification | CE, RoHS |
| Power (W) | Electric |
| Brand Name | Kamoer |
| Motor | DC motor |
| Flow | 10~60 ml/min |
| Pump Head | Engineering plastic |
| Noise | less than 40DB |
| Temperature | 0~40℃ |
| Humidity | less than 80% |
| Weight | 110 g |
| Mounting Plate | Straight plate/L plate |
| Pulse | 3 rotors, low pulse |
Tube Specifications and Flow Rates
| Material | Code | ID×OD (mm) | Flow Rate (ml/min) @ 12V | Flow Rate (ml/min) @ 6V | Flow Rate (ml/min) @ 24V |
|---|---|---|---|---|---|
| Silicone | S04 | 1.0×3.3 | ≥10 | ≥10.5 | ≥10 |
| Silicone | S06 | 2.0×4.0 | ≥37 | ≥36 | ≥38 |
| Silicone | S08 | 2.5×4.5 | ≥55 | ≥60 | ≥59 |
| BPT | B06 | 2.0×4.0 | ≥33 | ≥38 | ≥34 |
| BPT | B08 | 2.5×4.5 | ≥47 | ≥48 | ≥48 |
Tube Material Characteristics
| Tube Type | Material | Features | Tubing Life | Length |
|---|---|---|---|---|
| S | Silicone | Competitive price; Resistant to weak acid and base; Softest tube type; Commonly used in water pumps. | ≥200H | 175mm (49.5mm exposed) |
| B | PharMed BPT | Non-cytotoxic and non-hemolytic effect; Highly resistant to ozone and UV rays; Extreme resistance to acid, base, and heat; Anti-aging, antioxidant, long service time. Temperature range from -51℃ to 132℃. | ≥1000H | 135mm (29.5mm exposed) |

Image: Comparison of BPT and Silicone tubing options for the pump.
4. Setup
4.1 Mounting the Pump
The Kamoer NKP pump offers two mounting plate options: Straight plate and L-type plate, to accommodate different installation needs.

Image: Depicts the L-type and Straight mounting plates for flexible installation.
4.2 Power Connection
Connect the power cable to the pump. The pump motor has clearly marked terminals for positive (+) and negative (-) connections. Ensure correct polarity to prevent damage.

Image: Close-up of the pump motor showing the positive (+) and negative (-) terminals for power connection.
4.3 Tubing Installation
Insert the appropriate tubing (Silicone or BPT) into the pump head. Ensure the tubing is securely fitted. The pump is designed for easy tube changes.

Image: An exploded view of the pump head, illustrating the buckle joint for easy removal and tube replacement.
4.4 Tube Joints
Various tube joints are available for connecting tubing of different inner diameters (ID). Select the appropriate joint for your application:
| Joint Type | Straight | L Type | Y Type | T Type | Cross Type | ID Range |
|---|---|---|---|---|---|---|
| 1/16 (1.5mm) | 32050004 A0 | 32050027 A1 | 32050006 A2 | / | 32050039 A4 | 0.6 ≤ Φ ≤ 1.6 |
| 3/32 (2.3mm) | 32050038 B0 | 32050028 B1 | 32050029 B2 | 32050053 B3 | / | 1.6 ≤ Φ ≤ 2.4 |
| 1/8 (3mm) | 25010021 C0 | 32050037 C1 | 32050015 C2 | 32050020 C3 | 32050019 C4 | 2.4 ≤ Φ ≤ 3.2 |

Image: Illustrates different tube joint configurations and their corresponding IDs.
5. Operating Instructions
5.1 Basic Operation
Once the power cable is connected correctly, the pump will run at full speed at its rated voltage. The peristaltic design ensures that the liquid does not contact the pump itself, preventing pollution and making it suitable for sensitive liquids.
Video: Demonstration of connecting the power cable and observing the pump's operation, showing liquid transfer.
5.2 Flow Direction (Positive Inversion)
The pump features positive inversion, meaning it can dry-run and is self-priming. It also includes a stop valve function to prevent backflow in both directions. The flow direction can be reversed by swapping the positive and negative power connections.

Image: Illustrates the exchangeable positive and negative electrodes for controlling flow direction.
5.3 Noise Level
The Kamoer NKP pump operates at an ultra-silent level, typically less than 40dB, making it suitable for noise-sensitive environments.

Image: A digital sound level meter displaying a noise reading of 36.5 dB during pump operation, demonstrating its ultra-silent feature.
6. Maintenance
The Kamoer NKP pump is designed for low maintenance. The primary maintenance task involves changing the tubing.
6.1 Tube Replacement
- Disconnect the pump from its power source.
- Locate the buckle joint on the pump head.
- Carefully unclip the buckle joint to open the pump head.
- Remove the old tubing.
- Insert the new tubing, ensuring it is properly seated within the pump head.
- Close the buckle joint securely.
Regular inspection of the tubing for wear and tear is recommended, especially for silicone tubes which have a shorter lifespan compared to BPT tubes.

Image: An exploded view of the pump head, illustrating the buckle joint for easy removal and tube replacement.
7. Troubleshooting
- Pump not running:
- Check power connections for correct polarity (+/-).
- Ensure the power supply voltage matches the pump's rated voltage (6V, 12V, or 24V).
- Verify the power source is active.
- No liquid flow or reduced flow:
- Check for kinks or blockages in the tubing.
- Ensure the tubing is correctly installed in the pump head.
- Inspect tubing for wear, cracks, or damage; replace if necessary.
- Verify the liquid source is not empty.
- Confirm the suction side of the tube is submerged in the liquid.
- Excessive noise:
- Ensure the pump is securely mounted.
- Check for any foreign objects obstructing the pump mechanism.
8. User Tips
- For applications requiring precise dosing or handling sensitive liquids, consider using BPT tubing due to its longer lifespan and chemical resistance.
- When setting up, ensure the inlet tube is fully submerged in the liquid to prevent air intake and ensure consistent flow.
- The compact size of the pump (65mm x 48.5mm) allows for integration into various small-scale systems, such as aquariums or laboratory setups.
- The "Zero pollution, low pulse" design makes it ideal for applications where liquid purity and gentle transfer are crucial.

Image: A hand holding the pump, illustrating its small and powerful design with dimensions 65mm x 48.5mm.

Image: Cross-section diagram showing how liquid remains isolated from the pump mechanism, ensuring zero pollution and low pulse flow.
9. Warranty and Support
For warranty information or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.
10. Typical Applications
The Kamoer NKP Peristaltic Dosing Pump is versatile and can be used in various settings:
- Medical usage: For liquid transfer, sampling, dispensing.
- Chemical engineering usage: Sample analysis, dispensing liquid.
- Ink printer: For transferring ink, cleaning pipeline.
- Laboratory use: Liquid dispensing, extract liquid.
- Beverage: Dispensing, filling.
- Environmental usage: Transferring and sampling sewage.
- Factory usage: For liquid dispensing.
- Family usage: Watering flowers, garden irrigation.

Image: A collage showcasing diverse applications of the Kamoer NKP pump, from laboratory and industrial settings to home aquariums.