1. Introduction
The NJTY T-26C is a professional digital clamp meter designed for precise measurement of leakage current, micro AC current, and AC/DC voltage. It features an auto-ranging function and a high resolution of 0.01mA for AC current, making it suitable for various electrical testing applications. This manual provides essential information for the safe and effective use of your device.

2. Safety Information
Please read all safety warnings and operating instructions before using this instrument. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always ensure the meter is in the correct function and range before making measurements.
- Do not apply voltage or current that exceeds the maximum rated values for the meter.
- Exercise extreme caution when working with live circuits.
- Inspect the test leads for damage before each use. Do not use if insulation is damaged or bare metal is exposed.
- Do not operate the meter if it appears damaged or if it is not operating properly.
- Keep fingers behind the finger guards on the test probes during measurements.
- Replace batteries immediately when the low battery indicator appears to ensure accurate readings.
3. Product Overview and Components
Familiarize yourself with the parts of your NJTY T-26C clamp meter:

- Clamp Head: Used for non-contact current measurement. Maximum opening is 30mm. Features a gapless shielded magnetic design to reduce magnetic field interference.
- Wrench/Trigger: Opens the clamp head.
- Knob Shift: Rotary switch for selecting measurement functions and ranges. Features a two-color rubberized dial for precise gear shifting and comfortable feel.
- HOLD Button (Data Retention): Freezes the current reading on the display.
- SELECT Button (Function Selection): Toggles between different functions within a selected range (e.g., AC/DC voltage).
- Display Screen: Shows measurement readings, units, and other indicators. Features a 1999-word display.
- COM Jack: Common input terminal for test leads.
- V Jack (Voltage Jack): Input terminal for voltage measurements.
4. Setup
4.1. Battery Installation
The NJTY T-26C requires batteries for operation (not included). To install or replace batteries:
- Ensure the meter is turned OFF.
- Locate the battery compartment cover on the back of the meter.
- Use a screwdriver to open the battery compartment.
- Insert the required batteries, observing correct polarity (+ and -).
- Close the battery compartment cover and secure it with the screw.
4.2. Initial Checks
- Before first use, inspect the meter and test leads for any signs of damage.
- Ensure the rotary switch is in the 'OFF' position when not in use.
5. Operating Instructions
5.1. Measuring Leakage Current (AC Micro Current)
The T-26C is dedicated to measuring small AC currents, particularly leakage currents.

- Turn the rotary switch to the desired AC current range (20mA, 200mA, 2A, or 60A). The meter has auto-ranging capabilities.
- Press the trigger to open the clamp jaw.
- Encircle the conductor through which the leakage current is to be measured. For three-phase and five-wire systems (three-phase line, one working zero line, and ground lead), the ground line should be tested alone for leakage current.
- Release the trigger to close the clamp jaw around the conductor.
- Read the leakage current value on the display screen.
- To hold the reading, press the 'HOLD' button. Press again to release.

5.2. Measuring AC/DC Voltage

- Insert the black test lead into the 'COM' jack and the red test lead into the 'V' jack.
- Turn the rotary switch to the '600V' position (AC or DC, depending on the voltage type). The meter has auto-ranging.
- If measuring AC voltage, ensure the 'SELECT' button is pressed until 'AC' is indicated on the display. For DC voltage, ensure 'DC' is indicated.
- Connect the test probes across the circuit or component to be measured.
- Read the voltage value on the display screen.
- Note: The accuracy is lower when testing voltages below 100V.
5.3. Data Retention (HOLD Function)
Press the 'HOLD' button to freeze the current reading on the display. This is useful for taking readings in hard-to-reach areas or when the display is difficult to view directly. Press 'HOLD' again to resume live measurement.
5.4. Automatic Shutdown
The meter features an automatic shutdown function to conserve battery life. It will power off after a period of inactivity.
6. Maintenance
6.1. Cleaning
- Wipe the meter casing with a damp cloth and mild detergent. Do not use abrasives or solvents.
- Keep the clamp jaw clean and free of debris to ensure accurate current measurements.
6.2. Battery Replacement
Refer to section 4.1 for battery installation/replacement instructions. Always replace all batteries at the same time with new ones of the same type.
6.3. Storage
- When not in use for extended periods, remove the batteries to prevent leakage.
- Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
7. Troubleshooting
If the meter does not function correctly, check the following:
- No display or dim display: Check battery charge and ensure batteries are correctly installed. Replace if necessary.
- Incorrect readings: Ensure the correct function and range are selected. Check test lead connections. Ensure the clamp jaw is fully closed around the conductor for current measurements.
- 'OL' or 'OVER' on display: The measured value exceeds the selected range. Switch to a higher range if available, or verify the circuit is within the meter's capabilities.
- Meter does not turn on: Check batteries. Ensure the rotary switch is firmly in an 'ON' position.
8. Specifications

| Measurement Type | Range | Resolution | Accuracy |
|---|---|---|---|
| AC Current | 20mA | 0.01mA | ±(2.5% reading + 5 digits) |
| AC Current | 200mA | 0.1mA | |
| AC Current | 2A | 1mA | |
| AC Current | 60A | 100mA | ±(3% reading + 8 digits) |
| DC Voltage | 600V | ||
| AC Voltage | 600V |
Accuracy is ensured for one year at an environment temperature of 23℃±5℃ and relative humidity <75%. The accuracy is lower when testing voltage below 100V.
General Specifications:
- Display Screen: 1999 words
- Jaw Opening: 30mm
- Data Retention: Yes
- Automatic Shutdown: Yes
- DIY Supplies: Electrical
- Operating Mode: Manual Range
- Battery Included: No
- Dimensions (approx.): 186mm (Length) x 63mm (Width) x 29mm (Height)
- Weight (approx.): 136g
Note: All dimensions and weights are measured manually; slight variations may occur.
9. User Tips
- For precise leakage current measurements, especially in complex industrial setups, remember to isolate and test the ground line separately in three-phase, five-wire systems.
- Always ensure a good connection with the test leads for voltage measurements to avoid inaccurate readings.
- The auto-ranging feature simplifies operation, but always double-check the displayed unit to confirm you are reading the correct scale.
10. Warranty and Support
This product is covered by a standard manufacturer's warranty. For warranty claims, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.