EASUN POWER ISolar-SMH-III-6.2KW

EASUN Hybrid Solar Inverter SMH-III-6.2KW User Manual

Model: ISolar-SMH-III-6.2KW | Brand: EASUN POWER

1. Introduction

This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of your EASUN Hybrid Solar Inverter, model ISolar-SMH-III-6.2KW. This pure sine wave inverter is designed for both home appliances and personal computers, offering a configurable input voltage range, battery charging current, and AC/Solar charger priority. It is compatible with mains voltage or generator power and features overload, over-temperature, and short-circuit protection, along with a smart battery charger design for optimized battery performance and a cold start function. WIFI/GPRS connectivity is optional for remote monitoring.

The inverter has a rated power of 6200VA/6200W and a 48VDC battery system. It supports a maximum PV array power of 6000W with an MPPT operating voltage range of 55-450VDC and a maximum PV array open circuit voltage of 450VDC. The maximum charging current is 120A.

2. Safety Information

Please read all instructions and warnings carefully before installation and operation. Keep this manual for future reference. Only qualified personnel should perform installation and maintenance. Ensure all power sources are disconnected before performing any wiring or maintenance. Always connect the ground wire properly.

Important Safety Precautions:

3. Product Overview

The EASUN Hybrid Solar Inverter is a versatile unit designed to manage power from solar panels, batteries, and the utility grid. It features an LCD display for monitoring and configuration, along with LED indicators for status updates and function keys for navigation.

EASUN Hybrid Solar Inverter front view with LCD display and function keys
Figure 3.1: Front view of the Hybrid Solar Inverter showing LCD display and function keys.
EASUN Hybrid Solar Inverter rear view with connection ports labeled
Figure 3.2: Rear view of the Hybrid Solar Inverter with labeled connection ports.

3.1. Key Features

4. Installation

This section outlines the steps for installing the EASUN Hybrid Solar Inverter. Please ensure all safety precautions are followed before proceeding.

4.1. Physical Installation

The inverter should be mounted on a sturdy vertical surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient clearance around the unit for proper airflow.

EASUN Hybrid Solar Inverter mounted on a wall
Figure 4.1: Example of inverter wall mounting.

4.2. Wiring Connections

Refer to the following steps and diagrams for proper wiring. Always ensure power is OFF before making any connections.

  1. Connect the positive and negative battery terminals:

    Carefully connect the positive (red) and negative (black) battery cables to the corresponding terminals on the inverter. Ensure a secure connection.

    Video 4.2.1: Connecting battery terminals (0:09 - 0:21 in installation video).
    Battery Connection Diagram showing 4x12V batteries connected in series for a 48VDC system
    Figure 4.2.2: 48VDC Battery Connection Diagram. The 6.2KW model supports a 48VDC system, typically achieved by connecting four 12V batteries in series.
  2. Connect the positive and negative PV terminals:

    Connect the solar panel (PV) positive and negative cables to the designated PV input terminals on the inverter. Ensure correct polarity and secure connections.

    Video 4.2.3: Connecting PV terminals (0:25 - 0:33 in installation video).
    PV Connection Diagram for iSolar SMG II 6.2KP
    Figure 4.2.4: PV Connection Diagram for iSolar SMG II 6.2KP. When selecting PV modules, ensure the open circuit voltage (Voc) of PV modules does not exceed the maximum PV array open circuit voltage of the inverter, and the Voc of PV modules should be higher than the minimum battery voltage.
    PV Connection Diagram for iSolar SMG III 6.2KP
    Figure 4.2.5: PV Connection Diagram for iSolar SMG III 6.2KP. When selecting PV modules, ensure the open circuit voltage (Voc) of PV modules does not exceed the maximum PV array open circuit voltage of the inverter, and the Voc of PV modules should be higher than the minimum battery voltage.
    PV Connection Diagram for iSolar SMH III 6.2KW WIFI
    Figure 4.2.6: PV Connection Diagram for iSolar SMH III 6.2KW WIFI. When selecting PV modules, ensure the open circuit voltage (Voc) of PV modules does not exceed the maximum PV array open circuit voltage of the inverter, and the Voc of PV modules should be higher than the minimum battery voltage.
  3. Connect the positive and negative AC input terminals:

    Connect the AC input cables (Live, Neutral) to the appropriate AC input terminals on the inverter. Ensure these connections are tight and secure.

    Video 4.2.7: Connecting AC input terminals (0:34 - 0:42 in installation video).
  4. Connecting ground:

    Connect the ground wire to the designated ground terminal on the inverter. This is a critical safety step.

    Video 4.2.8: Connecting ground (0:43 - 0:47 in installation video).
  5. Install WIFI (Optional):

    If your model includes WIFI functionality, connect the WIFI module to the designated communication port. This allows for remote monitoring and control.

    Video 4.2.9: Installing WIFI module (0:01 - 0:08 and 1:02 - 1:07 in installation video).

4.3. Parallel Operation

The inverter supports parallel operation for increased power output. The 6.2KW model can be operated in parallel with up to nine inverters in a single phase configuration.

Parallel Operation in Single phase - Nine inverters in parallel Power Connection diagram
Figure 4.3.1: Parallel Power Connection Diagram for nine inverters in a single phase.

5. Operation

Once the inverter is installed and wired, follow these steps to begin operation and configure settings.

5.1. Initial Power-Up

  1. Turn on the battery and inverter switch:

    After all connections are secure, turn on the battery switch first, then the inverter's power switch. Wait for the parameter display to appear on the LCD screen.

    Video 5.1.1: Turning on battery and inverter switches (0:47 - 1:01 in installation video).

5.2. LCD Display and Function Keys

The inverter features an LCD display for real-time monitoring and configuration. Use the function keys to navigate menus and adjust settings.

LCD Display and Function Keys diagram
Figure 5.2.1: LCD Display and Function Keys.
LED Indicator Messages
LED IndicatorColorMessages
AC / INVGreenSolid On: Output is powered by utility in Line mode.
Flashing: Output is powered by battery or PV in battery mode.
CHGGreenSolid On: Battery is fully charged.
Flashing: Battery is charging.
A FAULTRedSolid On: Fault occurs in the inverter.
Flashing: Warning condition occurs in the inverter.
Function Keys Description
Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

5.3. Configuration Settings

The inverter allows for various configurable settings via the LCD display:

Refer to the detailed settings menu in the full product manual (if available) for specific parameter adjustments.

6. Specifications

Below are the detailed technical specifications for the EASUN Hybrid Solar Inverter ISolar-SMH-III-6.2KW.

CategoryParameterValue
GeneralModelISolar-SMH-III-6.2KW
Rated Power6200VA/6200W
InputVoltage230Vac
Selectable Voltage Range(170Vac~280Vac)±2% (for personal computers); (90Vac-280Vac)±2% (for home appliances)
Frequency Range50Hz/60Hz (Autodetection)
OutputAC Voltage Regulation (Batt. Mode)230VAC±5%
Surge Power14000VA
Transfer Time10ms (for personal computers) / 20ms (for home appliances)
WaveformPure Sine Wave
Battery & AC ChargerBattery Voltage48VDC
Floating Charge Voltage54VDC
Overcharge Protection61VDC
Maximum Charge Current120A
Solar ChargerMAX. PV Array Power6000W
MPPT Range @ Operating Voltage55-450VDC
Maximum PV Array Open Circuit Voltage450VDC
Maximum Charging Current120A
PhysicalDimension (D*W*H)423x310x120mm
Net Weight10.0kg
Communication InterfaceRS232/RS485 (Standard) / GPRS/WIFI (Optional)
Operating EnvironmentHumidity5% to 95% Relative Humidity (Non-condensing)
Operating Temperature5°C to 55°C
Storage Temperature5°C to 60°C

*Note: Specifications are subject to change without prior notice. Always refer to the product label for the most accurate information.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your EASUN Hybrid Solar Inverter.

8. Troubleshooting

This section provides guidance for common issues you might encounter with your inverter. For more complex problems, contact customer support.

Common Issues and Solutions
ProblemLED Indicator / DisplayPossible CauseSolution
No power / Inverter not turning onDisplay off, no LEDsNo battery connection, low battery voltage, inverter switch off.Check battery connections and voltage. Ensure inverter power switch is ON. Charge batteries if voltage is too low.
No AC outputAC/INV LED Solid On (Green) or Flashing (Green)Overload, short circuit, over-temperature, AC input not present.Reduce load. Check for short circuits in connected appliances. Allow inverter to cool down. Verify AC input connection.
Fault conditionA FAULT LED Solid On (Red)A fault has occurred in the inverter.Note any error codes on the LCD. Turn off the inverter, disconnect all power sources, wait a few minutes, then restart. If the fault persists, contact customer support.
Warning conditionA FAULT LED Flashing (Red)A warning condition exists, but the inverter may still be operating.Check the LCD display for specific warning messages. Address the underlying issue (e.g., high temperature, input voltage out of range).
Battery not chargingCHG LED Flashing (Green) or offPV input issue, AC input issue, battery fault, incorrect charging settings.Check PV connections and voltage. Verify AC input is present. Inspect battery health. Review charging current and priority settings via LCD.

9. Warranty and Support

EASUN POWER is committed to providing high-quality products and customer satisfaction. This product comes with certain guarantees and support services.

9.1. Returns and Refunds

9.2. Customer Service

For any questions, technical assistance, or warranty claims, please contact EASUN POWER Flagship Store customer service. Ensure you have your product model number and purchase details ready.

Store Name: EASUN POWER Flagship Store
Seller ID: cn1076568331fvqae
Positive Feedback: 90.7%

9.3. Security & Privacy

Your security and privacy are important. Payments are safe, and personal details are protected and kept secure, not shared with third parties without consent.

Related Documents - ISolar-SMH-III-6.2KW

Preview EASUN POWER SMH-III Hybrid Solar Inverter User Manual (3.6KW/4.2KW/6.2KW)
This user manual provides comprehensive information on the EASUN POWER SMH-III Hybrid Solar Inverter series, covering models 3.6KW, 4.2KW, and 6.2KW. It details installation, operation, specifications, and troubleshooting for reliable uninterruptible power solutions.
Preview EASUN POWER IGrid SV II 6KW On-Grid Inverter with Energy Storage - Technical Specifications
Detailed technical specifications and selection guide for the EASUN POWER IGrid SV II 6KW On-Grid Inverter with Energy Storage. Features include pure sine wave output, hybrid operation modes, and parallel capabilities.
Preview EASUN POWER Hybrid 3.6KW/5.6KW Inverter/Charger User Manual
Comprehensive user manual for the EASUN POWER Hybrid 3.6KW and 5.6KW Inverter/Charger systems, detailing installation, operation, specifications, troubleshooting, and advanced features like parallel operation and Wi-Fi connectivity for efficient solar energy management.
Preview Easun Power ISolar SMG II 6.2KP Hybrid Solar Inverter/Charger User Manual
Comprehensive user manual for the Easun Power ISolar SMG II 6.2KP (6.2KVA 230Vac) hybrid solar inverter/charger, covering installation, operation, specifications, and troubleshooting for reliable power solutions.
Preview Easun Power: Comprehensive Solar Solutions and Inverters
Explore Easun Power's extensive range of high-quality solar inverters, charge controllers, batteries, and solar panels designed for residential and commercial applications. Discover innovative energy solutions for a sustainable future.
Preview EASUN POWER ISolar-SMX-II-5.6KW Solar Charge Inverter User Manual
This user manual provides comprehensive instructions for the EASUN POWER ISolar-SMX-II-5.6KW solar charge inverter, covering its features, installation, operation, safety guidelines, and technical specifications for efficient solar energy storage and management.