SMART SENSOR ST8904

Contents

SMART SENSOR ST8904 Multifunctional Gas Detector User Manual

Model: ST8904 | Brand: SMART SENSOR

1. Introduction

The SMART SENSOR ST8904 is a professional 4-in-1 gas detector designed for the continuous monitoring of Carbon Monoxide (CO), Hydrogen Sulfide (H₂S), Oxygen (O₂), and Combustible Gas (LEL) concentrations in the surrounding environment. This high-precision, portable device features a compact size and light weight, making it easy to carry and operate. It provides sound, vibration, and flash alarms when gas concentrations reach predefined alarm levels, ensuring safety in various industrial and environmental settings.

2. Key Features

  • 4-in-1 Gas Detection: Simultaneously detects Carbon Monoxide (CO), Hydrogen Sulfide (H₂S), Oxygen (O₂), and Combustible Gas (LEL).
  • Continuous Monitoring: Provides real-time, accurate measurement of gas concentrations.
  • Triple Alarm System: Alerts users with sound, vibration, and flashing lights when gas levels exceed set limits.
  • Large Color LCD Display: High-definition display with backlight for clear and easy reading of measurements.
  • Adjustable Alarm Settings: Allows setting of upper and lower alarm limits, Time-Weighted Average (TWA), and Short-Term Exposure Limit (STEL) values.
  • Battery Charging Function: Equipped with a rechargeable battery and Micro USB charging port.
  • Sampling Pump Compatibility: Can be connected to an external sampling pump for operation in confined or closed spaces.
  • Durable Construction: Made from ABS material for robust performance.
SMART SENSOR ST8904 Gas Detector highlighting key features
SMART SENSOR ST8904 Gas Detector highlighting key features: smart sensor, sound/vibration/flash alarm, battery charging, accurate measurements, large color LCD, and adjustable alarm settings.

3. Package Contents

Please check the package carefully to ensure all items are present and undamaged:

  • 1 x SMART SENSOR ST8904 4-in-1 Gas Detector
  • 1 x USB Cable (for charging)
  • 2 x Screws
  • 1 x Gas Calibration Hood
  • 1 x Storage Bag
  • 1 x User Manual (English)
SMART SENSOR ST8904 Gas Detector and included accessories
SMART SENSOR ST8904 Gas Detector and included accessories: USB cable, screws, gas calibration hood, storage bag, and user manual.

4. Technical Specifications

ParameterValue
Brand NameSMART SENSOR
Model NumberST8904
ColorBlue
MaterialABS
Screen Size47 * 38mm (1.9 * 1.5in)
Display TypeSegment type LCD with backlight
Sensor PrincipleElectrochemical Principle
Detection GasesCarbon Monoxide (CO), Hydrogen Sulfide (H₂S), Oxygen (O₂), Combustible Gas (LEL)
CO Measurement Range0~999ppm
H₂S Measurement Range0~500ppm
O₂ Measurement Range0~30%VOL
LEL Measurement Range0~100%LEL
CO Resolution1ppm
H₂S Resolution1ppm
O₂ Resolution0.1%VOL
LEL Resolution1%LEL
Alarm AlertSound, Vibration, Flash (Triple Alarms)
Alarm Value SettingUpper limit, Lower limit, TWA, STEL
Battery TypeBL-9C (Rechargeable)
Charging PortMicro USB DC 5V
Operation Voltage3.7V
Operation Current230mA
Battery Working RuntimeApprox. 6 hours (without alarm)
Operation Humidity15%~95%RH
Operation Temperature-10℃~50℃
Storage Temperature0~40℃
Item Size140 * 75 * 35mm (5.51 * 2.95 * 1.37in)
Item Weight270g (9.52oz)
CertificationCE

5. Setup Guide

5.1 Initial Charging

Before first use, fully charge the device. Connect the provided USB cable to the Micro USB port on the detector and to a standard 5V DC USB power adapter (not included). The charging indicator on the device will show the charging status. A full charge typically takes several hours.

5.2 Power On/Off

  • To Power On: Press and hold the power button (usually marked with a power symbol) until the LCD screen illuminates.
  • To Power Off: Press and hold the power button until the device powers down.

5.3 Basic Operation

Upon powering on, the device will typically perform a self-test and then enter continuous monitoring mode, displaying the current concentrations of CO, H₂S, O₂, and LEL on the LCD screen.

5.4 Alarm Value Setting

The detector allows for customization of alarm thresholds. Refer to the detailed English User Manual included in your package for specific instructions on how to set the upper limit, lower limit, TWA (Time-Weighted Average), and STEL (Short-Term Exposure Limit) alarm values. These settings are crucial for tailoring the device to specific safety requirements.

5.5 Calibration

Regular calibration is essential for maintaining the accuracy of your gas detector. Use the included Gas Calibration Hood and follow the instructions in the comprehensive user manual for proper calibration procedures. Calibration should be performed in a clean air environment or with certified calibration gases as recommended by safety standards.

Close-up view of the ST8904 gas detector's LCD display and control buttons
Close-up view of the ST8904 gas detector's LCD display and control buttons.

6. Operating Instructions

6.1 Continuous Monitoring

Once powered on, the ST8904 continuously monitors the ambient air for the four specified gases. The current concentration levels are displayed on the large LCD screen. Ensure the sensor inlet is unobstructed for accurate readings.

6.2 Alarm Response

If any detected gas concentration reaches or exceeds its set alarm threshold, the device will activate its triple alarm system:

  • Audible Alarm: A loud beeping sound.
  • Vibrating Alarm: The device will vibrate.
  • Visual Alarm: Flashing lights on the device.

Upon an alarm, immediately assess the situation and take appropriate safety measures, such as evacuating the area or initiating ventilation. Do not re-enter an alarmed area until gas levels have returned to safe limits.

6.3 Using with a Sampling Pump (Optional)

For monitoring in confined spaces or areas difficult to access, the ST8904 can be connected to an external sampling pump (DC 3V power supply). This allows for remote sampling of air, drawing it into the detector for analysis. Ensure the sampling pump is correctly attached and functioning before use in such environments.

7. Maintenance

7.1 Cleaning

Wipe the exterior of the detector with a soft, damp cloth. Do not use abrasive cleaners, solvents, or immerse the device in water. Keep the sensor inlet free from dust and debris.

7.2 Storage

When not in use, store the detector in its provided storage bag in a cool, dry place, away from direct sunlight and extreme temperatures (Storage Temperature: 0~40℃). Ensure the battery is partially charged before long-term storage to prevent deep discharge.

7.3 Battery Care

Recharge the battery when the low battery indicator appears on the display. Avoid completely draining the battery frequently to prolong its lifespan. Use only the specified Micro USB DC 5V charging method.

7.4 Sensor Lifespan and Replacement

Gas sensors have a limited lifespan. While the exact lifespan can vary based on usage and environmental conditions, regular calibration helps to identify when sensors may need replacement. Consult the full user manual or contact customer support for information on sensor replacement.

8. Troubleshooting

  • Device does not power on: Ensure the battery is fully charged. If the issue persists, try charging with a different USB cable or adapter.
  • No gas readings: Check if the sensor inlet is clear of obstructions. Ensure the device is in an environment where gas is expected. If in a clean air environment, readings should be near zero (except O₂).
  • Alarm not sounding/vibrating/flashing: Verify that alarm settings are correctly configured. Check the device's volume and vibration settings. Ensure the battery has sufficient charge.
  • Inaccurate readings: Perform a calibration as described in the user manual. Ensure the device is used within its specified operating temperature and humidity ranges.
  • LCD display issues: If the display is dim or unreadable, ensure the backlight is active and the battery is charged.

For persistent issues not covered here, please refer to the detailed user manual or contact customer support.

9. User Tips

  • Customize TWA/STEL: Take advantage of the ability to modify Time-Weighted Average (TWA) and Short-Term Exposure Limit (STEL) alarm values to suit specific workplace safety regulations or personal preferences. This allows for more precise monitoring over different exposure durations.
  • Regular Calibration: Even if readings appear consistent, perform regular calibrations to ensure long-term accuracy and reliability of the sensors.
  • Environmental Awareness: Always be aware of the environmental conditions (temperature, humidity) as they can affect sensor performance.

10. Warranty and Support

The SMART SENSOR ST8904 Multifunctional Gas Detector is manufactured to high-quality standards. For specific warranty details, please refer to the warranty card included with your product or contact the seller directly. Keep your purchase receipt as proof of purchase.

For technical support, troubleshooting assistance, or inquiries regarding parts and service, please contact your point of purchase or the SMART SENSOR customer service department.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.