Introduction
This manual provides detailed instructions for the safe and efficient operation, setup, and maintenance of your IHERDSMAN 8 Head Ultrasonic Atomizer. This device is designed to create mist for various applications, including humidifying air in gardens, pools, rockeries, greenhouses, and hydroponic systems. Please read this manual thoroughly before using the product to ensure proper function and longevity.
Product Structure and Components
The 8 Head Ultrasonic Atomizer is constructed with durable materials and features an intelligent design for optimal performance.

- Stainless Steel Shell: Provides durability and corrosion resistance.
- Ceramic Base: Houses the ultrasonic atomizing sheets.
- Power Indicator: Illuminates when the device is powered on.
- Removable Copper Pressure Ring: Secures the atomizing sheets in place for easy replacement.
- Automatic Induction Water Shortage Protection: Automatically shuts off the device when water levels are too low to prevent damage.
- Atomizer Plate: The core component responsible for mist generation.
- Power Supply: Converts AC power to DC 48V for the atomizer. Available with Euro or US plug.
- Buoys (Optional): Square or Half-Round buoys can be used to maintain optimal water depth for the atomizer.
Specifications
| Feature | Detail |
|---|---|
| Product Name | 8 Head Ultrasonic Atomizer |
| Material | Aluminum Alloy |
| Color | Silver |
| Type | Air Humidifier / Fogger |
| Application | Gardens, pools, rockeries, greenhouses, hydroponics, indoor fish ponds |
| Atomizer Plate Wire Length | 5 meters |
| Operating Voltage | DC 48V |
| Power Supply Model (US Plug) | SZ-350W-48V |
| Power Supply Input (US Plug) | 90-130Vac, 50/60 Hz, 6A Max |
| Power Supply Output (US Plug) | DC 48V, 7.3A |
| Power Supply Input (Euro Plug) | 180-260Vac, 50/60 Hz, 3.5A Max |
| Power Supply Output (Euro Plug) | DC 48V, 8.4A |
| Power Supply IP Rating | IP67 |
| Indoor Usage Area (8 head) | Up to 4 m² |
| Outdoor Usage Area (8 head) | Up to 3 m² |
| Fogging Amount (8 head) | 4-5.6 kg/h |



Setup Instructions
- Unpack Components: Carefully remove the atomizer, power supply, and any optional buoys from their packaging.
- Choose Location: Place the atomizer in your desired water feature (pond, pool, tank, etc.). Ensure the location allows for proper mist dispersion and is away from sensitive electronics.
- Ensure Proper Water Level:
- For optimal atomization, the water surface should be approximately 1-1.5 cm above the sensing head of the atomizer when stationary.
- If using buoys, place the atomizer within the buoy. You can adjust the water level of the fogger by filling the hollow float with water to achieve the ideal depth.

Figure 5: Ideal Water Level. The best atomization effect is achieved when the water surface is 1-1.5 cm away from the sensing head. 
Figure 6: Buoy Water Level Adjustment. Filling the hollow float with water allows for precise adjustment of the fogger's depth in the water. - Connect Power Supply: Connect the atomizer's cable to the power supply using the 2-pin male-female waterproof connector. Ensure a secure and tight connection to maintain waterproofing.

Figure 7: Waterproof Connector. Illustrates the correct way to connect the atomizer to its power supply using the waterproof connector. - Plug In: Plug the power supply into a suitable electrical outlet (90-130Vac for US plug, 180-260Vac for Euro plug).
Operating Instructions
- Power On: Once connected and placed in water, the atomizer will begin to produce mist. The power indicator light on the atomizer will illuminate.
- Monitor Water Level: The device features automatic induction water shortage protection. If the water level drops too low, the atomizer will automatically shut off to prevent damage. Refill water as needed to resume operation.
- Observe Mist Output: Ensure the mist is dispersing as desired for your application. Adjust the atomizer's depth using buoys or by adding/removing water if necessary to optimize mist production.

Maintenance
- Regular Cleaning: Periodically clean the ceramic base and atomizing sheets to prevent mineral buildup, which can reduce mist output. Use a soft brush and clean water. Do not use harsh chemicals.
- Atomizing Sheet Replacement: The atomizing sheets are consumable parts and will need replacement over time.
- To replace, carefully remove the copper pressure ring using a small wrench.
- Replace the old atomizing sheet with a new one, ensuring it is seated correctly.
- Secure the new sheet by re-attaching the copper pressure ring.

Figure 9: Atomizing Sheet Replacement. The atomizing sheet can be replaced with the aid of a small wrench. - Water Quality: Using distilled or demineralized water can help extend the life of the atomizing sheets and reduce mineral buildup.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No mist production |
|
|
| Low mist output |
|
|
| Atomizer stops unexpectedly |
|
|
User Tips
- For best results and to prolong the life of your atomizer, consider using purified or distilled water to minimize mineral deposits on the ceramic discs.
- When placing the atomizer, ensure it is in a stable position and cannot be easily dislodged, especially in active water features.
- Regularly check the power supply and its connections for any signs of wear or damage, particularly as it is an IP67 rated waterproof unit, ensuring its integrity is key.
Warranty and Support
This product is manufactured to high-quality standards. For any issues or support inquiries, please contact the seller or manufacturer directly. Please retain your proof of purchase for warranty claims.