LILYTECH ZL-7801A Temperature and Humidity Controller User Manual

Intelligent Universal Controller for Temperature and Humidity

1. Introduction

The LILYTECH ZL-7801A is an intelligent, universal temperature and humidity controller designed for precise environmental management. Its compact design, IP65 front panel protection, and user-friendly interface make it suitable for a wide range of applications, including incubators, climate chambers, and warehouses.

2. Key Features

  • Intelligent temperature and humidity control.
  • Compact design for easy integration.
  • IP65 level front panel protection against dust and water splashes.
  • Convenient operation with intuitive buttons.
  • Easy installation process.
  • Multiple output loads for various applications.

3. Package Contents

Upon opening the package, please verify that all items are present and in good condition:

  • 1 x ZL-7801A Temperature and Humidity Controller
  • 1 x Humidity and Temperature Sensor (wire length 1.5 meter)
  • Connecting terminals/connectors (e.g., red crimp connectors)

Note: Other products not explicitly listed above are not included in the standard package.

4. Product Overview

4.1. Controller Unit

The ZL-7801A features a clear digital display and four control buttons on the front panel. The rear panel provides terminal blocks for power, sensor input, and various load outputs.

Front view of LILYTECH ZL-7801A controller with sensor and connectors

Figure 1: Front view of the ZL-7801A controller, showing the digital display, control buttons (P, Up, S, Down), and the included temperature/humidity sensor with connectors.

Front view of LILYTECH ZL-7801A controller only

Figure 2: Close-up of the ZL-7801A controller's front panel.

Rear view of LILYTECH ZL-7801A controller showing terminal blocks

Figure 3: Rear view of the ZL-7801A controller, displaying the various terminal blocks for electrical connections.

4.2. Control Buttons

  • P (Program) Button: Used to enter and exit programming mode, and to confirm settings.
  • ▲ (Up) Button: Used to increase values or navigate through menu options.
  • S (Set) Button: Used to view current setpoints or select parameters.
  • ▼ (Down) Button: Used to decrease values or navigate through menu options.

5. Specifications

ParameterValue
Power Supply100 ~ 240Vac 50/60Hz
Input SignalOne humidity and temperature sensor
Sensor Wire Length1.5 meter
Output Load R15A/250Vac (Resistive load)
Output Load R2 & R316A/250Vac (Resistive load)
Output Load R4 & R53A/250Vac (Resistive load)
Humidity Setting Range5 ~ 95% RH
Temperature Setting Range-20 ~ 60℃
Humidity Sensor Accuracy±5%
Temperature Sensor Accuracy±1%
Working Environment Humidity10 ~ 90% RH (without dew)
Working Environment Temperature-20 ~ 45℃
Drilling Size (W*H)71 * 29 mm
Case MaterialsPC + ABS, fire proof
Protection LevelIP65 (front panel only)
ColorBlack
Dimensions (L*W*H)78 x 34.5 x 71 mm

6. Installation

6.1. Mounting the Controller

The ZL-7801A is designed for panel mounting. Follow these steps:

  1. Prepare a rectangular opening in your control panel with dimensions of 71 mm (width) x 29 mm (height).
  2. Insert the controller into the opening from the front.
  3. Secure the controller using the provided mounting clips on the sides. Ensure it is firmly seated.
Side view of LILYTECH ZL-7801A showing mounting clips

Figure 4: Side view illustrating the mounting clips for panel installation.

6.2. Wiring Diagram

WARNING: All wiring should be performed by a qualified electrician and with the power supply disconnected to prevent electric shock. Ensure all connections are secure and comply with local electrical codes.

The ZL-7801A has multiple terminals for power, sensor input, and various load outputs (R1, R2, R3, R4, R5). Refer to the diagram below for correct wiring. The loads are based on resistive load ratings.

Wiring diagram for LILYTECH ZL-7801A temperature and humidity controller

Figure 5: Detailed wiring diagram for the ZL-7801A controller. This diagram shows connections for the 100-240VAC power supply, the humidity and temperature sensor, and the five relay outputs (R1, R2, R3, R4, R5) with their respective Normally Open (NO), Normally Closed (NC), and Common (COM) terminals.

Terminal Connections:

  • Power Supply (100-240VAC, 50/60Hz): Connect your main power input to the designated power terminals.
  • Humidity & Temperature Sensor: Connect the sensor cable to the dedicated sensor input terminals. Ensure correct polarity if applicable.
  • R1, R2, R3, R4, R5 (Relay Outputs): Each relay has Common (COM), Normally Open (NO), and Normally Closed (NC) terminals. Connect your controlled devices (e.g., heaters, humidifiers, fans) to the appropriate relay terminals based on your control logic.

7. Operating Instructions

The ZL-7801A allows you to set desired temperature and humidity levels. The specific programming steps will depend on the desired control mode (e.g., heating, cooling, humidifying, dehumidifying). Refer to the full programming manual (if available) for advanced settings.

7.1. Powering On/Off

Connect the controller to the power supply as per the wiring instructions. The display will illuminate, showing the current temperature and humidity readings from the sensor.

7.2. Basic Parameter Setting (Example: Temperature Setpoint)

While the exact sequence may vary for all parameters, a typical setting process involves:

  1. Press and hold the 'S' button to view the current setpoint.
  2. Press the 'P' button to enter programming mode (or a combination of 'P' and 'S').
  3. Use the '▲' and '▼' buttons to navigate through parameters or adjust values.
  4. Press 'P' or 'S' again to confirm a setting and move to the next parameter or exit programming mode.

Consult the detailed programming guide for specific parameter codes and their functions (e.g., temperature hysteresis, humidity differential, alarm settings).

8. Maintenance

To ensure optimal performance and longevity of your LILYTECH ZL-7801A controller, follow these maintenance guidelines:

  • Cleaning: Regularly wipe the front panel with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the display or casing.
  • Sensor Care: Keep the temperature and humidity sensor clean and free from dust or debris. Ensure it is not exposed to direct water spray or extreme physical impact.
  • Environmental Conditions: Operate the controller within the specified working environment temperature and humidity ranges to prevent damage. Avoid locations with excessive vibration, corrosive gases, or strong electromagnetic interference.
  • Connection Checks: Periodically inspect all wiring connections to ensure they remain tight and secure. Loose connections can lead to erratic behavior or damage.

9. Troubleshooting

If you encounter issues with your ZL-7801A controller, refer to the following common problems and solutions:

  • Controller does not power on:
    • Check the power supply connections to ensure they are correctly wired and receiving the specified voltage (100-240Vac).
    • Verify that the power source is active.
  • Display shows abnormal readings or 'Err' message:
    • Check the temperature and humidity sensor connection. Ensure it is securely plugged in and not damaged.
    • The sensor might be faulty. Try replacing it if possible.
    • Ensure the sensor is placed in an appropriate environment and not exposed to extreme conditions beyond its operating range.
  • Controlled device (e.g., heater, humidifier) is not activating:
    • Verify the wiring of the controlled device to the correct relay output (R1-R5) terminals (COM, NO, NC).
    • Check the setpoints for temperature and humidity to ensure they are configured to trigger the device under current conditions.
    • Ensure the controlled device itself is functional and powered.
    • Review the controller's programming parameters (e.g., hysteresis, delay settings) which might prevent immediate activation.
  • Buttons are unresponsive:
    • Ensure the controller is not in a locked mode (if such a feature exists, refer to the full manual).
    • Power cycle the device by disconnecting and reconnecting the power supply.

If the problem persists after attempting these solutions, please contact customer support.

10. User Tips

  • For critical applications, consider using an external thermometer/hygrometer to cross-verify the ZL-7801A's readings periodically.
  • When setting parameters, make small adjustments and observe the system's response to avoid overshooting desired conditions.
  • Keep a record of your parameter settings for easy reference, especially after power outages or if settings need to be reset.

11. Warranty and Support

For any technical assistance, warranty claims, or further inquiries regarding the LILYTECH ZL-7801A controller, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.