SUMRY MPS VIII ECO

Contents

SUMRY MPS VIII ECO Series Hybrid Solar Inverter User Manual

Model: MPS VIII ECO

Brand: SUMRY

1. Introduction

This manual provides essential information for the installation, operation, and maintenance of the SUMRY MPS VIII ECO Series On/Off Grid Pure Sine Wave Hybrid Solar Inverter. This series includes 3.6KW, 4.2KW, and 6.2KW models, designed to provide reliable and continuous power for various applications. Please read this manual thoroughly before installation and use to ensure optimal performance and safety.

SUMRY MPS VIII ECO Series Inverter with key specifications
Figure 1: SUMRY MPS VIII ECO Series Inverter with key specifications (Max Solar Charge Current 120A, Battery Voltage 24V/48V, Max PV Input 500VDC, Frequency Range 50Hz/60Hz, 1 Year Warranty).

Key Features:

  • Pure sine wave output for sensitive electronics.
  • Configurable input voltage range for home appliances and personal computers.
  • Configurable battery charging current based on applications.
  • Configurable AC/Solar Charger priority.
  • Compatible with mains voltage or generator power.
  • Automatic restart upon AC recovery.
  • Overload, over temperature, and short circuit protection.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.
  • Optional WIFI/GPRS communication for monitoring.

2. Safety Information

Always observe the following safety precautions to reduce the risk of injury and to prevent damage to the inverter or connected equipment:

  • Ensure proper grounding of the inverter.
  • Do not disassemble the inverter. Refer all servicing to qualified personnel.
  • Keep the inverter away from flammable materials, moisture, and direct sunlight.
  • Ensure adequate ventilation around the inverter to prevent overheating.
  • Use appropriate circuit breakers for all connections as detailed in the installation section.
  • Verify correct polarity when connecting batteries and solar panels.
Inverter protection features icons
Figure 2: Comprehensive protection features including Overload, Overheating, High/Low Voltage, Battery, Short Circuit, Overcurrent, Anti-Reverse, and Power Failure Protection.

3. Product Overview

The SUMRY MPS VIII ECO Series inverter is a versatile hybrid solution designed for both on-grid and off-grid solar power systems. It converts DC power from solar panels or batteries into stable AC power, suitable for a wide range of appliances.

Multi-angle view of the SUMRY inverter
Figure 3: Multi-angle view of the SUMRY MPS VIII ECO Series Inverter.

Supported Battery Types:

The inverter is compatible with various battery technologies, offering flexibility for different energy storage needs:

  • Flooded Batteries (FLD)
  • Gel Batteries (GEL)
  • LiFePO4 Batteries (LI)
  • Lithium Batteries (LI)
  • AGM Batteries (AGM)
  • User Custom Batteries (USER)
Inverter compatible with multiple battery types
Figure 4: Inverter compatibility with various battery types.

Product Demonstration:

Watch this video for an unboxing and connection demonstration of the SUMRY MPS VIII ECO Series Inverter.

Video 1: Unboxing and Connection Demonstration of the SUMRY MPS VIII ECO Series Inverter.

4. Installation

Proper installation is crucial for the safe and efficient operation of your inverter. It is recommended to install four circuit breakers in the following positions:

  1. Between the battery pack and the inverter battery input.
  2. Between the solar panel and the photovoltaic input of the inverter.
  3. Between the power input of the grid and the inverter.
  4. Between inverter output and load.

The circuit breaker effectively prevents misconnection or reverse connection of the mains input and the inverter output. In case of a short circuit, load short circuit, or overload in the output, the circuit breaker will cut off the circuit to protect the inverter.

Inverter installation diagram with circuit breakers
Figure 5: Recommended circuit breaker positions in the inverter system.

System Architecture:

Basic System Architecture diagram for On/Off Grid Solar Inverter
Figure 6: Basic System Architecture showing power flow from solar panels, utility, generator, and battery.

Rear Panel Connections:

Numbered diagram of inverter rear panel connections
Figure 7: Rear panel connections: 1. AC input, 2. Main output, 3. Second output, 4. Battery communication RS-485 port, 5. WIFI communication RS-232 port, 6. PV input, 7. Battery input.

Battery Connection:

For optimal performance, connect battery packs as shown in the diagram below. Ensure all 12V batteries are connected in series to achieve the required voltage for your inverter model (e.g., 24V or 48V).

Battery connection diagram for 6.2KW and 4.2KW inverters
Figure 8: Battery connection diagram for 6.2KW and 4.2KW inverters, showing multiple 12V batteries in series.

Communication Ports:

The inverter supports different communication configurations. Please note that ECO 4.2KW/6.2KW models will be updated to "Dual Communication" after July 2024. Orders placed before July will typically feature "Single Communication" (especially for Brazil ship orders).

Communication ports diagram (Single vs. Dual Communication)
Figure 9: Comparison of Single Communication and Dual Communication ports, highlighting BMS, WiFi, RS485, and RS232 options.

5. Operation

The inverter features an intuitive LCD display and function buttons for easy configuration and monitoring.

LCD Display and Function Buttons:

Inverter LCD display, LED indicators, and function buttons
Figure 10: LCD display, LED indicators, and function buttons with their descriptions.

LED Indicator Messages:

  • INV/AC (Green, Solid On): Output is powered by utility in Line mode.
  • INV/AC (Green, Flashing): Output is powered by battery or PV in battery charged mode.
  • CHG (Green, Solid On): Battery is fully charged.
  • CHG (Green, Flashing): Battery is charging.
  • FAULT (Red, Solid On): Fault occurs in the inverter.
  • FAULT (Red, Flashing): Warning condition occurs in the inverter.

Function Keys:

  • ESC: To exit setting mode.
  • UP: To go to previous selection.
  • DOWN: To go to next selection.
  • ENTER: To confirm the selection in setting mode or enter setting mode.

Remote Monitoring:

The inverter supports optional WIFI/GPRS modules for remote monitoring and control via the SmartESS App. Download the app from your device's app store (e.g., App Store, Google Play).

SmartESS App monitoring via WiFi
Figure 11: Monitor and control via SmartESS App with optional WiFi module.

6. Specifications

Detailed specifications for the SUMRY MPS VIII ECO Series inverters are provided below. Please refer to the specific model for accurate values.

Table 1: Product Data Sheet for MPS-VIII ECO Series
MODELMPS-VIII ECO 3.6KWMPS-VIII ECO 4.2KWMPS-VIII ECO 6.2KW
Phase1-phase
PV INPUT (DC)
Nominal DC Voltage/Maximum DC Voltage360/500VDC
Start-up Voltage/Initial Feeding Voltage90VDC/120VDC90VDC/120VDC
MPPT Voltage Range60-450VDC
Maximum Input Current1/18A1/22A1/22A
GRID OUTPUT (AC)
Nominal Output Voltage220/230/240VAC
Output Voltage Range195-253VAC
Nominal Output Current15.7A18.2A27.0A
Power Factor>0.99
EFFICIENCY
Maximum Conversion Efficiency (DC/AC)98%
TWO LOAD OUTPUT POWER
Maximum Main Load3600W4200W6200W
Maximum Second Load (battery mode)1200W1400W2067W
Maximum Load Cut Off Voltage26VDC52VDC26VDC
Maximum Load Return Voltage27VDC54VDC27VDC
OFF-GRID OPERATION
AC Input Start-up Voltage/Auto Restart Voltage120-140VAC/180VAC
Acceptable Input Voltage Range90-280VAC or 170-280VAC
Frequency Range59-61±1HZ
Maximum AC Input Current21.1A24.7A36.4A
BATTERY CHARGER
Nominal DC Voltage24VDC48VDC24VDC
Maximum Solar Charging Current120A80A120A
Maximum AC Charging Current100A60A100A
Maximum Solar+AC Charging Current120A80A120A
Product Data Sheet for MPS-VIII ECO Series
Figure 12: Detailed Product Data Sheet for MPS-VIII ECO Series.
Table 2: General, Physical, Interface, Environment, and Standard Specifications
CategoryDescription
GENERAL
Continous Power3000W
Output Power1 - 200 KW
Output Current20A
Output Frequency50/60HZ
AC output voltage110/220V-50Hz/60Hz
Wave FormPure Sine Wave
AC input230VAC(4.2kw 6.2kw), 120VAC(3.6KW)
Battery voltage24/48VDC
Max charge current for battery60A
Max charge current for solar80A
PHYSICAL
Dimension (D*W*H) (mm)420*350*110
Cartoon Dimension (D*W*H) (mm)500*415*180
Net Weight (kgs)8.0 (for 3.6KW/4.2KW), 8.9 (for 6.2KW)
Gross Weight (kgs)9.0 (for 3.6KW/4.2KW), 10.0 (for 6.2KW)
INTERFACE
Communication PortRS232/RS485/WIFI/GPRS/LITHIUM BATTERY
ENVIRONMENT
Humidity5% to 95% Relative Humidity (Non-condensing)
Operating Temperature-10°C ~ 50°C
STANDARD
CertificationCE, FCC

7. Troubleshooting

This section provides guidance on common issues indicated by the inverter's LED lights. For more complex problems, please contact customer support.

LED Indicator Troubleshooting:

  • FAULT (Red, Solid On): Indicates a fault within the inverter. Check all connections, input/output voltages, and ensure no overloads. If the fault persists after restarting, contact support.
  • FAULT (Red, Flashing): Indicates a warning condition. This could be due to high temperature, low battery voltage, or other non-critical issues. Check the environment for proper ventilation and battery status.
  • INV/AC (Green, Flashing): Inverter is operating from battery or PV power. If this is unexpected, check AC input connection and grid status.

8. Maintenance

Regular maintenance helps ensure the longevity and reliable operation of your SUMRY inverter.

  • Cleaning: Periodically clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings are free from dust and debris.
  • Inspection: Regularly inspect all wiring connections for tightness and signs of corrosion. Check for any visible damage to the inverter casing or cables.
  • Environment: Ensure the inverter is installed in a cool, dry, and well-ventilated area, away from direct sunlight and moisture.

9. User Tips

Based on common user inquiries and feedback, here are some helpful tips:

  • Fan Noise: While designed for efficient cooling, some fan noise is normal during high load or charging. Ensure the inverter has ample space for airflow to prevent excessive fan operation due to heat.
  • Battery-less Operation: The SUMRY MPS VIII ECO series is capable of operating without batteries, directly supplying power from solar panels or the grid to your loads. This feature can be configured via the LCD settings.
  • Pre-purchase Research: For optimal system design, it is advisable to study your specific power needs and system components (solar panels, batteries) before purchasing an off-grid solar inverter.

10. Warranty and Support

The SUMRY MPS VIII ECO Series Inverter comes with a 1-year warranty from the date of purchase. For technical support, warranty claims, or any operational questions, please contact SUMRY Official Store customer service. Ensure you have your purchase details and model number ready.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.