1. Introduction
This manual provides essential information for the safe and effective installation, operation, and maintenance of your EARU Residual Current Circuit Breaker (RCBO/MCB). Please read these instructions carefully before installation and retain them for future reference. This device is designed to protect against earth fault/leakage current, short-circuit, and overload in electrical circuits.
2. Product Features
- Provides protection against earth fault/leakage current.
- Offers protection against short-circuit and overload.
- Includes an isolation function.
- Features contact position indication for clear status.
- Provides protection against indirect contact by human body.
- Offers complementary protection against direct contact by human body.
- Effectively protects electric equipment against insulating failure.
- Equipped with switched neutral and phase pole.
- Provides protection against over-voltage.
- Offers comprehensive protection to household and commercial distribution systems.

Figure 1: Key Protection Features
3. Technical Specifications
| Attribute | Value |
|---|---|
| Type | Electronic, Residual Current (AC) |
| Pole No. | 1P+N |
| Tripping Curve | C Type |
| Rated Short-Circuit Capacity | 6KA |
| Rated Current (A) | 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A |
| Rated Voltage | 230VAC (also 220V~) |
| Rated Frequency | 50/60Hz |
| Rated Residual Operating Current | 30mA (15mA for 63A models) |
| Tripping Duration | Instantaneous (≤ 0.1s) |
| Over-voltage Tripping | 280V ± 5% |
| Connection Capacity | Flexible conductor 10mm², Rigid conductor 16mm² |
| Mounting | Symmetrical DIN Rail 35mm, Panel mounting |
| Certifications | CE |
| Standards | IEC61009, GB6829 |
| Mechanical Lifespan | 20,000 cycles |

Figure 2: Product Dimensions and Current Ratings
4. Safety Information
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel.
- Always disconnect power before installing or servicing the device.
- Ensure proper grounding according to local electrical codes.
- Do not operate the device if it appears damaged.
- Verify that the rated voltage and current of the device match your electrical system requirements.
- Test the device monthly using the test button.
5. Installation
The circuit breaker is designed for installation on a symmetrical 35mm DIN rail or panel mounting. Ensure adequate space for wiring and ventilation.
5.1 Component Identification

Figure 3: Circuit Breaker Components
5.2 Mounting
To mount the device, align the clips on the back of the circuit breaker with the DIN rail and press firmly until it clicks into place. For panel mounting, use appropriate accessories.

Figure 4: DIN Rail Mounting Clips

Figure 5: Circuit Breakers Mounted on DIN Rail
5.3 Wiring
Connect the incoming phase (L) and neutral (N) wires to the upper terminals and the outgoing load wires to the lower terminals as indicated by the wiring diagram on the device. Ensure all connections are tight using the tighten screws. The terminal connection height is H1=16mm and H2=21mm. The device supports flexible conductors up to 10mm² and rigid conductors up to 16mm².

Figure 6: Wiring Diagrams (refer to device labels)
6. Operation
To operate the circuit breaker:
- **Switching ON:** Push the operating handle (red lever) upwards to the "ON" position. The window indication should show the "ON" status.
- **Switching OFF:** Push the operating handle downwards to the "OFF" position. The window indication should show the "OFF" status.
- **Tripping:** In case of an electrical fault (overload, short-circuit, or leakage), the circuit breaker will automatically trip, moving the operating handle to an intermediate position or "OFF".
Video 1: Demonstration of the circuit breaker's operation, including the test button and switching mechanism.
7. Maintenance
To ensure continued safety and proper functioning, it is crucial to perform a monthly test of the residual current device (RCD) function.
- **Monthly Test:** Press the "Test Monthly" button (marked 'T' or yellow button) on the front of the device. The circuit breaker should trip immediately. If it does not trip, the device may be faulty and should be replaced by a qualified electrician.
- After testing, reset the circuit breaker by pushing the operating handle to the "ON" position.
8. Troubleshooting
- **Device trips frequently:** This indicates an electrical fault. Check for overloads, short circuits, or earth leakage in the protected circuit. Do not repeatedly reset the breaker without identifying and resolving the fault.
- **Device does not reset:** If the breaker does not reset after tripping, ensure the fault has been cleared. If the problem persists, the device may be damaged or there might be a persistent fault. Consult a qualified electrician.
- **Test button does not trip the device:** The RCD function may be faulty. The device should be replaced immediately by a qualified electrician.
9. User Tips
- For optimal safety and compliance with electrical standards, it is highly recommended that installation and any complex troubleshooting be performed by a certified electrician.
- Regularly inspect the device for any visible signs of damage or wear.
10. Warranty and Support
For warranty information and technical support, please refer to the seller's official store or contact their customer service. Keep your purchase records for any warranty claims.