1. Introduction

The ZEEWEII DSO3D12 is a highly integrated and versatile electronic test instrument, combining a 120MHz bandwidth digital oscilloscope, a high-accuracy true RMS multimeter, and a 2.5V signal generator into a single compact device. Designed with ARM and FPGA chip collocation, it offers high-speed signal acquisition and data processing, ensuring a smooth user experience and rich functionality. This manual provides detailed instructions for setup, operation, and maintenance of your DSO3D12.

ZEEWEII DSO3D12 3-in-1 Smart Oscilloscope
Figure 1: ZEEWEII DSO3D12 Smart Oscilloscope (3-in-1) highlighting its core functions.

Its wide range of applications makes it suitable for single-chip debugging, car maintenance, home appliance maintenance, DIY debugging, electronic competitions, power supply debugging, frequency converter analysis, and more.

Video 1: ZEEWEII DSO3D12 Product Demonstration showcasing various modes and features like time base, vertical sensitivity, roll mode, single trigger, dual channel, XY mode, persistence, signal generator, FFT, zoom, and multimeter functions.

2. Package Contents

Upon opening your ZEEWEII DSO3D12 package, please verify that all the following items are included:

Package list for ZEEWEII DSO3D12
Figure 2: Contents of the ZEEWEII DSO3D12 package, including the device and accessories.
  • ZEEWEII DSO3D12 Main Unit
  • Oscilloscope Probes (2 units)
  • Multimeter Test Leads (Red and Black)
  • USB Type-C Charging Cable
  • Mini Screwdriver
  • Color Rings for Probe Identification
  • User Manual (this document)

The device dimensions are approximately 145mm (Length) x 32mm (Width) x 86mm (Height).

3. Setup Guide

Before using your DSO3D12, please follow these initial setup steps:

  1. Charging the Device: Connect the provided USB Type-C cable to the device and a compatible 5V power adapter. The battery icon on the display will indicate charging status. A full charge typically takes about 6 hours.
  2. Power On/Off: Press and hold the power button (usually located on the side or top) to turn the device on or off.
  3. Language Selection: Navigate to the settings menu to select your preferred language (English is supported).
  4. Collapsible Stand: Utilize the integrated collapsible stand for convenient desktop use and optimal viewing angle.

4. Operating Instructions

4.1. Oscilloscope Functions

Smart and Multifunction Oscilloscope
Figure 3: The DSO3D12 functions as a smart and multifunction oscilloscope.

The oscilloscope features a 120MHz bandwidth (for CH1 only, 60MHz in dual-channel mode) and a 500M equivalent sampling rate, with a real-time sampling rate of 250MSa/s. It is equipped with various modes and measurement capabilities:

120MHz Bandwidth Oscilloscope
Figure 4: High bandwidth capabilities of the DSO3D12, showing dual channel and multimeter modes.

4.1.1. Fully Automatic Mode

Fully Automatic Oscilloscope Mode
Figure 5: One-key auto and fully automatic modes for simplified waveform adjustment.

The DSO3D12 supports both one-key automatic and fully automatic modes. Simply click the "Auto" button to perform waveform detection and display waveforms. In fully automatic mode, no keystrokes are required, and continuous automaticity is performed, making it easy for novices to quickly get started.

4.1.2. Trigger Modes

Perfect Trigger Modes
Figure 6: Trigger settings for stable waveform capture, including Auto, Normal, and Single trigger modes.

The device offers Auto trigger, Normal trigger, and Single trigger modes. Trigger type can be set to Rise or Fall, Trigger Level to Manual or Auto, and Trigger Source to CH1 or CH2.

4.1.3. Dual Channel Operation

Dual Channel Oscilloscope
Figure 7: The DSO3D12 in dual-channel mode, showing CH1 and CH2 inputs.

When channel 2 is turned on, the device operates in dual-channel mode, allowing simultaneous measurement and display of two signal waveforms. This is useful for comparative analysis, such as observing phase differences or dead times in complementary PWM signals.

4.1.4. XY Mode

XY Mode Lissajous Figures
Figure 8: Examples of Lissajous figures displayed in XY Mode.

XY mode combines the waveforms of two channels to form an image, commonly used to observe Lissajous figures and analyze phase relationships between two signals.

4.1.5. Persistence and Reference Waveform

Reference Waveform Display
Figure 9: Displaying a reference waveform for comparison.

The persistence feature allows you to observe how waveforms change over time, showing a trail of past waveforms. The device also supports latching reference waveforms, statically displaying a waveform on the screen while dynamic waveforms continue to refresh, useful for comparison.

4.1.6. FFT Spectrum Analysis

FFT Spectrum Analysis
Figure 10: Fast Fourier Transform (FFT) spectrum display, showing frequency components of a waveform.

FFT (Fast Fourier Transform) converts waveforms from the time domain to the frequency domain, allowing analysis of frequency components. It supports linear and logarithmic displays. Note: FFT displays spectrograms; direct frequency measurement is not supported.

4.1.7. Zoom and Cursor Measurement

Cursor Measurement Function
Figure 11: Using X and Y cursors for precise waveform measurements.

The DSO3D12 supports zoom functionality for detailed waveform inspection. Cursor measurement allows for precise analysis: X cursors measure time intervals between two pulses, and Y cursors measure voltage and voltage differences at any two points.

4.1.8. Waveform Save and View

Waveform Save and View Interface
Figure 12: Interface for saving and viewing captured waveforms.

You can save screen waveforms with one click. The device features a picture browsing page where you can view saved waveforms in full-screen and delete unwanted waveform charts.

4.1.9. Measurement Options

The oscilloscope provides 14 types of automatic measurements:

  • Frequency
  • Peak-to-Peak (P-eak to P-eak)
  • Duty Cycle
  • Amplitude
  • RMS (Root Mean Square)
  • Average
  • Period
  • +Pulse Width
  • -Pulse Width
  • Maximum (Max)
  • Minimum (Min)
  • Top
  • Base
  • -Duty Cycle
Oscilloscope with rich features
Figure 13: The DSO3D12 display showing various measurement items and features.

4.2. Multimeter Functions

High-precision Multimeter
Figure 14: The DSO3D12 functioning as a high-precision multimeter.

The built-in true RMS multimeter supports fast software calibration and can measure voltage, current, resistance, diode, continuity, and capacitance. The multimeter is isolated from the oscilloscope, allowing both functions to be used simultaneously (with the multimeter display in a small window in the upper right corner).

High-precision Multimeter Display
Figure 15: Multimeter display showing voltage measurement.

4.3. Signal Generator

Signal Generator Function
Figure 16: The DSO3D12's built-in signal generator in action.

The integrated waveform signal generator can output sine wave, square wave, triangle wave, half wave, and Singh wave signals. The voltage amplitude is 2.5V, the frequency is adjustable from 0-2MHz, and the square wave duty cycle is adjustable from 1% to 99%.

4.4. Display and Personalization

HD IPS Display
Figure 17: The 3.2-inch high-definition IPS display.

The DSO3D12 features a 3.2-inch high-definition IPS display, providing a clear and delicate display with a full viewing angle. Channel 2 waveforms can be customized with green, cyan, or purple colors for better differentiation.

More Screenshots of Display Modes
Figure 18: Various display modes and personalization options, including generator full screen, multimeter small window, multimeter function select, multimeter full screen, 14 measure items, personalization settings, and different waveforms (50MHz/3Vpp Sin, 20MHz Square).

5. Specifications

Oscilloscope Parameters Table
Figure 19: Detailed oscilloscope parameters.

5.1. General Parameters

  • Model: DSO3D12
  • Screen size: 3.2 inch
  • Language: English
  • Bracket: Collapsible stand
  • Key type: Soft silicone keys
  • Charging: TYPE-C 5V
  • Battery time: about 6 hours
  • Case size: 14.5 * 8.6 * 3.2cm
  • Material: ABS

5.2. Oscilloscope Parameters

ParameterValueParameterValue
Channels2CouplingAC/DC
Real time sample rate250MSa/sAuto modeoneKey-auto/fully-auto
Bandwidth120MHz (CH1 Only) / 60MHz (CH1+CH2)SensitivityX1:10mV/div~10V/div, X10:100mV/div~100V/div
Equivalent sampling500MMeasure items14 types
Rise time<3nsDC Offset±2%
Storage128kbXY modeyes
Impedance1MΩScreenshotyes
TimeBase5ns~10sFrequency±0.01%
Peak voltage±40V (1x), ±400V (10x)Zoom modeyes
Trigger modeauto/normal/singleGenerator wavesin/square/triangular...
Trigger typerise/fallGenerator Vol2.5V±0.05
Display modeYT/XY/rollGenerator freq1Hz~2MHz
Persistencenone/1s/∞FFTyes

5.3. Multimeter Parameters

Multimeter Parameters Table
Figure 20: Detailed multimeter parameters.
FunctionRangePrecision
DC voltage600mV/6.00V/60.0V/600V/750V±(0.5%+3)
AC voltage600mV/6.00V/60.0V/600V±(1%+3)
DC current600mA / 10A±(2%+5)
AC current600mA / 10A±(3%+5)
Current note: 600mA hole with 1A fuse, 10A hole without fuse
Resistance600.0Ω, 6.000kΩ/60.00kΩ/600.0kΩ, 6.000MΩ, 60.00MΩ±(1.5%+3), ±(1%+3), ±(1.5%+5), ±(3%+3)
Capacitance60.00nF/600.0nF/6.000μF, 60.00μF/600.0μF±(5%+5), ±(10%+5)
Diode0.0V~3.3V, 3.3V higher display OL
ContinuitySound at 50Ω and below

6. Maintenance and Safety

Safe Design Features
Figure 21: The DSO3D12 features a safe design with isolation, protecting against high voltage.

The DSO3D12 incorporates a safe design with a peak 400V anti-burn feature. It uses an isolation transformer and isolation optocoupler chip to isolate the multimeter from the oscilloscope, ensuring safety when measuring high voltage, as the multimeter and oscilloscope can be used simultaneously without common ground issues.

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Charge it regularly, even if not in use for extended periods.
  • Probe Handling: Handle probes carefully. Avoid bending or stressing the cables excessively.
  • Safety Precautions: Always observe proper electrical safety procedures when working with circuits. Ensure the device is used within its specified voltage and current limits.

7. Troubleshooting

If you encounter issues with your ZEEWEII DSO3D12, consider the following common troubleshooting steps:

  • Device not powering on: Ensure the battery is charged. Connect the device to a 5V Type-C charger and allow it to charge for at least 30 minutes before attempting to power on again.
  • No waveform displayed:
    1. Check probe connections to both the device and the circuit under test.
    2. Verify that the input signal is within the device's voltage range.
    3. Try using the "Auto" button to automatically adjust settings.
    4. Adjust the vertical sensitivity (V/div) and time base (s/div) settings manually.
    5. Ensure the trigger settings are appropriate for the signal being measured.
  • Multimeter readings are incorrect:
    1. Ensure test leads are correctly inserted into the appropriate jacks (e.g., 10A for high current, VΩmA for voltage/resistance/low current).
    2. Check the function selection on the device to match the measurement type (voltage, resistance, etc.).
    3. Verify the test leads are making good contact with the component being measured.
  • Signal generator not outputting:
    1. Ensure the signal generator function is active and configured correctly (waveform type, frequency, amplitude).
    2. Check the connection from the signal generator output to the circuit.

If problems persist, please refer to the official ZEEWEII support channels for further assistance.

8. Warranty and Support

The ZEEWEII DSO3D12 comes with a standard manufacturer's warranty. Please retain your proof of purchase for warranty claims. For technical support, warranty inquiries, or service, please contact ZEEWEII Official Store directly through the platform where the product was purchased. You may also find additional resources and FAQs on the manufacturer's website.

Contact Information: Refer to your purchase platform or the ZEEWEII Official Store for the most up-to-date contact details.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.