1. Overview
The INKBIRD IHT-1M is a versatile 3-in-1 food thermometer designed to assist in various cooking tasks. It integrates the functions of a foldable probe for internal temperature measurement, an infrared sensor for surface temperature, and a cooking timer. This device provides accurate temperature readings quickly and includes preset menus for different meat types and doneness levels, along with an alarm function for target temperatures. Its non-contact infrared measurement ensures safer and more hygienic food preparation. The IHT-1M is an ideal tool for home cooks and grilling enthusiasts.

2. Product Features
- 3-in-1 Functionality: Combines a meat thermometer, non-contact infrared thermometer, and cooking timer.
- Chef-Recommended Preset Menus: Equipped with preset menus for five types of meats, each with five doneness levels and corresponding target temperatures.
- Cooking Timer and Temperature Alarm: Functions as a kitchen timer (count-up/count-down) and provides an audible alarm when the target temperature is reached.
- Instant Reading: High-precision food-grade probe provides readings in 2-3 seconds.
- High Accuracy: Probe temperature measurement accuracy of ±1.0°F/±0.5°C.
- Wide Temperature Range: Probe: -58.0°F~572°F (-50.0°C~300°C); Infrared: -58.0°F~482°F (-50.0°C~200°C).
- Calibration Function: Supports calibration for both probe and infrared temperature measurements.
- Content-Rich Backlit LCD Screen: Displays detection temperature, target temperature, meat type, doneness, and more, visible from any angle.
- Motion-Activated Design: Features auto on/off, auto sleep, and auto wake-up functions.
- Magnetic Design: Allows for convenient storage on metallic surfaces.
- Rechargeable Battery: Built-in 250mAh lithium battery, fully charged in approximately 1 hour via Type-C port.
3. Product Layout and Components

The IHT-1M thermometer features a sleek design with clearly labeled buttons and a digital display. Key components include:
- LCD Screen: Displays temperature, timer, meat type, and doneness levels.
- Infrared Temperature Detection Port: Located at the top for non-contact surface temperature measurement.
- Foldable Probe: A food-grade stainless steel probe for internal temperature readings.
- Type-C Charging Port: For recharging the internal battery.
- Action Buttons: MEAT, OK, +, -, DONENESS, IR, HOLD/°F/°C.


4. Setup
Before first use, ensure the thermometer is fully charged. Connect the provided Type-C charging cable to the charging port on the device and a suitable USB power source. The battery icon on the display will indicate charging status. A full charge typically takes 1 hour.

The device powers on automatically when the probe is unfolded or any button is pressed. It will enter auto-sleep mode after a period of inactivity to conserve battery.
5. Operating Instructions
This section details how to use the various functions of your INKBIRD IHT-1M thermometer.
5.1 Action Button Overview
- MEAT: Press to select Meat/Custom/Timer mode. Press and hold for 2 seconds to enter temperature calibration settings.
- DONENESS: Press to select the doneness level of meat. In timer mode, press and hold for 2 seconds to select positive or countdown timer, then use +/- to adjust value.
- IR: Press and hold to perform an infrared measurement. Release to lock the temperature display. Press any button to unlock.
- OK: Confirm button.
- HOLD/°F/°C: When measuring with the probe, press to lock/unlock the displayed temperature. In timer mode, press to start/stop timing. Press and hold for 2 seconds to switch between °F and °C temperature units.
- +/-: Adjust values up or down.
5.2 Setting Meat Type and Doneness
To set the meat type and desired doneness (e.g., Beef, Medium Rare):
- Press the MEAT button to cycle through meat types until "Beef" is selected.
- Press the DONENESS button to cycle through doneness levels until "MEDIUM RARE" is selected.
- Press the OK button or wait 30 seconds for the settings to be confirmed and saved automatically.

5.3 Setting Custom Temperature
To set a custom target temperature (e.g., 174°F):
- Press the MEAT button to select "Custom" mode. The target temperature value will flash.
- Use the + or - buttons to adjust the target temperature to your desired value (e.g., 174°F).
- Press the OK button or wait 30 seconds for the settings to be confirmed and saved automatically.

5.4 Using the Countdown Timer
To set a countdown timer (e.g., 10 minutes):
- Press the MEAT button to select Timer mode. The time parameter will flash.
- Ensure the screen displays "Down". If not, press and hold the DONENESS button for 2 seconds to toggle the display.
- Use the + or - buttons to adjust the time to 10 minutes.
- Press the OK button or wait 30 seconds for the settings to be confirmed and saved automatically.
- Press the HOLD button to start/stop the timer. The "Down" character will flash when the timer is running.
Note: While the countdown is active, you can adjust the time using the +/- buttons. Press OK to confirm and restart the countdown with the new duration, or wait 10 seconds for it to resume with the original setting.
5.5 Using the Positive Timer (Count-Up)
To set a positive timer (e.g., 10 minutes):
- Press the MEAT button to select Timer mode. The time parameter will flash.
- Press and hold the DONENESS button for 2 seconds to toggle to the positive timer function. The screen will display "UP".
- Use the + or - buttons to adjust the time to 10 minutes.
- Press the OK button or wait 30 seconds for the settings to be confirmed and saved automatically.
- Press the HOLD button to start/stop the timer. The "UP" character will flash when the timer is running.
Note: While the positive timer is active, you can adjust the time using the +/- buttons. Press OK to confirm and restart the timer with the new duration, or wait 10 seconds for it to resume with the original setting.
5.6 Infrared Temperature Measurement
For non-contact surface temperature measurement:
- Point the infrared detection port towards the surface you wish to measure.
- Press and hold the IR button. The current surface temperature will be displayed.
- Release the IR button to lock the temperature display. Press any other button to unlock.

5.7 Probe Temperature Measurement
For internal temperature measurement:
- Unfold the stainless steel probe. The device will automatically power on if it was in sleep mode.
- Insert the probe into the thickest part of the food, avoiding bones.
- Read the temperature displayed on the LCD screen.
- Press the HOLD button to lock the current temperature reading on the display. Press again to unlock.

6. Calibration
To ensure accuracy, you can calibrate both the probe and infrared temperature measurements.
- Press and hold the MEAT button for 2 seconds to enter the probe temperature calibration setting. The screen will display "CA" and the corresponding parameter will flash.
- Use the + or - buttons to adjust the probe calibration value (e.g., to 0.5°F).
- Press the MEAT button again to switch to infrared temperature calibration. The screen will display "IRCA" and the corresponding parameter will flash.
- Use the + or - buttons to adjust the infrared calibration value (e.g., to 1.0°F).
- Press the OK button or wait 30 seconds for the settings to be confirmed and saved automatically.
7. User Tips
- Magnetic Storage: Utilize the magnetic back of the thermometer to conveniently attach it to your refrigerator or oven for easy access.
- Probe Care: Always clean the probe thoroughly after each use with a damp cloth. Do not immerse the entire unit in water.
- Infrared Distance: For accurate infrared readings, maintain a distance of approximately 10cm (D:S 1:1) from the target surface.
- Battery Life: A fully charged battery provides ample usage time. Remember to recharge when the battery indicator is low.

8. Specifications
| Attribute | Value |
|---|---|
| Product Name | Multi-functional Thermometer |
| Model Number | IHT-1M |
| Probe Response Time | 2~3 seconds |
| Probe Temperature Range | -58.0°F~572°F (-50.0°C~300°C) |
| Probe Temperature Measurement Accuracy | ±1.0°F/±0.5°C |
| Probe Temperature Calibration Range | -9.9°F~9.9°F (-4.9°C~4.9°C) |
| Infrared Emissivity | 0.95 |
| Infrared Temperature Range | -58.0°F~482°F (-50.0°C~200°C) |
| Infrared Temperature Measurement Accuracy | ±2% of the reading |
| Infrared Thermometer Distance Ratio | D:S 1:1, 10±2cm |
| Infrared Temperature Calibration Range | -9.9°F~9.9°F (-4.9°C~4.9°C) |
| Timer Setting Range | 0~990 minutes (10 minutes as a unit) |
| Battery Life | 250mAh (fully charged in 1 hr) |
| Warranty | 1 Year |
| Certifications | CE, FCC |
| Display Type | DIGITAL |
| Is Smart Device | No |
For a detailed table of temperature relationships between meat type and doneness, please refer to the official user manual PDF: INKBIRD IHT-1M User Manual (PDF)
9. Safety Information
FCC Requirement:
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
General Safety:
- This product is NOT waterproof. Do NOT immerse it in water or rinse it with water.
- Keep out of reach of children.
- Do not expose the device to extreme temperatures or direct sunlight for extended periods.
- Use only the provided charging cable.
10. Warranty and Support
The INKBIRD IHT-1M comes with a 1-year warranty from the date of purchase.
For technical support, warranty claims, or any inquiries, please contact:
INKBIRD TECH.C.L.
Email: support@inkbird.com
Office address: Room 1803, Guowei Building, NO.68 Guowei Road, Xianhu Community, Liantang, Luohu District, Shenzhen, China