JUNCTEK LC-200A

Contents

JUNTEK LC-200A Digital LC Meter User Manual

Model: LC-200A

1. Important Safety Instructions

Before using this product, read and understand all instructions in this manual. Retain this manual for future reference.

Intended Use:

This product is for household use only. Use only as described in this manual.

Product Condition:

Do not use the product if it is damaged in any way.

User Suitability:

This product is intended for persons aged 18 years and above. It may be used by persons with reduced physical, sensory or mental capabilities, or lack of experience/knowledge, only if they are supervised or instructed on safe use and understand the hazards involved.

JUNTEK LC-200A Digital LC Meter with test clips and USB cable, displaying measurement ranges.

Figure 1: JUNTEK LC-200A Digital LC Meter and included accessories.

2. Product Overview

The JUNTEK LC-200A is a multifunctional inductance and capacitance measuring instrument designed for accurate and convenient testing of small value components. It features four measuring positions and an online calibration system that retains parameters even after power loss, ensuring consistent accuracy.

Video 1: Overview of the JUNTEK LC-200A Digital LC Meter's features and operation.

3. Setup

3.1 Power Supply

The LC-200A can be powered via a Mini USB cable, a Φ5.5DC socket, or by 4 AA batteries. Ensure the correct power source is connected before operation.

3.2 Battery Installation

To install batteries, open the battery compartment cover located on the back of the device. Insert 4 AA batteries, ensuring correct polarity. Close the cover securely.

Back view of the JUNTEK LC-200A meter showing the battery compartment and kickstand.

Figure 2: Rear view of the LC-200A, illustrating the battery compartment.

3.3 Connecting Test Clips

Connect the provided alligator test clips to the Lx/Cx terminals on the front of the meter. Ensure a secure connection for accurate measurements.

4. Operating Instructions

4.1 Powering On and Calibration

Once powered, the device will display measurement information on its 1602 LCD. The LC-200A features online calibration, meaning parameters are saved internally and will not be lost after power-off, ensuring consistent accuracy.

JUNTEK LC-200A meter with text 'Online calibration' and 'Parameters won't lost after power off'.

Figure 3: The LC-200A's online calibration feature.

4.2 Zeroing the Meter

Important: Always reset the meter to zero before testing a capacitance or inductance. Failure to do so may damage the board or result in inaccurate readings.

4.3 Performing Measurements

The LC-200A supports four measuring positions: Small Capacitance (C), Large Capacitance (Hi.C), Small Inductance (L), and Large Inductance (Hi.L). Select the appropriate range using the function buttons.

  • Capacitance (C Range): For values from 1pF to 10uF.
  • Large Capacitance (Hi.C Range): For values from 1uF to 100mF.
  • Inductance (L Range): For values from 1uH to 100mH.
  • Large Inductance (Hi.L Range): For values from 0.001mH to 100H.

When measuring the frequency of inductance or capacitance, press the black button (Func) to cycle through measurement modes. Connect the component to the Lx/Cx terminals using the alligator clips.

JUNTEK LC-200A meter displaying 'MEASURE Lx 1.036uH', indicating an inductance measurement.

Figure 4: Measuring inductance (Lx) with the LC-200A.

JUNTEK LC-200A meter displaying 'MEASURE Hi.C 4.71mF', indicating a large capacitance measurement.

Figure 5: Measuring large capacitance (Hi.C) with the LC-200A.

5. Maintenance

To ensure the longevity and accuracy of your LC-200A meter, follow these maintenance guidelines:

  • Keep the device clean and free from dust and moisture. Use a soft, dry cloth for cleaning.
  • Store the meter in a cool, dry place when not in use.
  • If using batteries, remove them if the device will not be used for an extended period to prevent leakage.
  • Avoid dropping or subjecting the device to strong impacts.

6. Troubleshooting

  • Inaccurate Readings: Ensure the meter has been zeroed before each measurement. Check that test clips are securely connected to the component.
  • Device Not Powering On: Verify that the power supply (USB or batteries) is correctly connected and functional. If using batteries, check their charge level and replace if necessary.
  • "Damage the board" Warning: This warning in the product description emphasizes the importance of zeroing the meter before connecting components. Always perform the zeroing procedure as instructed in section 4.2.

7. Specifications

Dimensions of the JUNTEK LC-200A meter: 29mm/1.14in height, 150mm/5.9in length, 89mm/3.5in width.

Figure 6: Physical dimensions of the LC-200A meter.

FeatureSpecification
C Range (Capacitance)1pF - 10uF
Capacitance Accuracy (C Range)1% (1pF~1uF), 5% (1uF~10uF)
Capacitance Resolution (C Range)0.01pF
Hi.C Range (Large Capacitance)1uF - 100mF
Large Capacitance Accuracy (Hi.C Range)5% (1uF-100mF)
Large Capacitance Resolution (Hi.C Range)0.01uF
L Range (Inductance)1uH - 100mH
Inductance Accuracy (L Range)1% (1uH~100mH)
Inductance Resolution (L Range)0.001uH
Hi.L Range (Large Inductance)0.001mH - 100H
Large Inductance Accuracy (Hi.L Range)1% (100mH~1H), 5% (1H~100H)
Large Inductance Resolution (Hi.L Range)0.001mH
Test Frequency (L/C Range)500kHz
Test Frequency (Hi.L Range)500Hz - 50KHz
Measurement Method (C, L, Hi.L)LC Resonance
Measurement Method (Hi.C)Charge-discharge
Display1602 LCD (4 effective digits)
Power Supply InterfaceMini USB & Φ5.5DC Socket, 4x AA Batteries
Supply Voltage5V
Dimensions (L*W*H)150 x 89 x 29 mm
Weight198g
Package Size200 x 160 x 60 mm
Package Weight280g

8. Warranty and Support

Manufacturer Information:

Manufacturer: Shenzhen Ruibozhi Electronics Co., Ltd

Address: 103, No. 2028 Banxuegang Avenue, Yangmei Community, Bantian Street, Longgang District, Shenzhen, Guangdong Province, China

EU Representative:

Company: MJCM SARL

Address: 78 avenue des Champs Elysees, Bureau 326, France

Phone: +33-752907452

Email: mjcm190928@gmail.com

Certifications:

The JUNTEK LC-200A is certified with CE, FC, and RoHS standards, indicating compliance with health, safety, and environmental protection directives.

Additional Resources:

A detailed user manual in PDF format is available for download. Please refer to the official product page or contact customer support for the link.

9. User Tips

  • For the most accurate readings, ensure the device is placed on a stable, non-vibrating surface.
  • When measuring very small values, minimize external interference and ensure good contact with the test clips.
  • The online calibration feature makes the device robust against sudden power losses, but regular zeroing is still crucial for precision.

10. Package Contents

The product package includes the following items:

  • 1 x JUNTEK LC-200A Capacitance Meter
  • 1 x Mini USB Power Cable
  • 2 x Alligator Test Clips

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.