Introduction
The KKNOON K618 is a versatile digital cable tester and multimeter designed for network installers and technicians. This advanced instrument combines essential functions such as cable tracing, cable length measurement, POE (Power over Ethernet) testing, and a comprehensive digital multimeter. It offers precise and efficient diagnostics for a wide range of metal cables, including network cables, telephone lines, and BNC cables.
Key features include a long tracing distance, clear sound signals for identification, quick and accurate cable length measurement up to 500 meters, and the ability to detect short circuits and circuit breaks in real-time. The cable tracing function is particularly useful for quickly locating target cables within a large bundle. The integrated multimeter expands its utility, making it a practical tool for laboratories, factories, and field service.
Package Contents
Please check the package carefully to ensure all items are present and in good condition:
- 1 x KKNOON K618 Host Unit
- 1 x Wire Tracker Receiver
- 3 x Remote ID Mapping Tools
- 1 x Storage Bag
- 1 x User Manual
- 1 x Clip Line (Alligator Clip Cable)
- 1 x Network Cable
- 1 x USB Recharging Cable
- 1 x Temperature Probe
- 1 x Multimeter Probes (Pair)

Specifications
| Feature | Specification |
|---|---|
| Model Number | KKNOON K618 |
| Brand Name | meterk |
| Material | ABS |
| Color | Orange |
| Analogue Tracing | Yes |
| Switch Tracing (w/PoE) | Yes |
| Cable Mapping | Yes |
| Switch Indicators Flashing | Yes |
| Digital Tracing | Digital/Vibration (Noisy free) |
| PoE Voltage Measuring | Voltage polarity detection |
| Analogue Bargraph | Yes |
| NCV Detection | Yes |
| Network Cable Length Measure | Up to 500M |
| ID Pairing Function | Yes (with 3 remote ID tools) |
| Host Power | Built-in 1250mAh rechargeable battery |
| Receiver Power | 1 x 9V battery (NOT INCLUDED) |
Multimeter Specifications:
- DC Voltage: 400mV~1000V ±(0.8%+3)
- AC Voltage: 4V~400V ±(1.5%+5)
- DC Current: 1.0A~10.0A ±(1.2%+4)
- AC Current: 1.0A~10.0A ±(2.0%+5)
- Resistance: 200Ω~20MΩ ±(2%+6)
- Continuity: < 50Ω (buzzer beeps)
- Diode: Yes
- Temperature (K type): -20~1000°C ±(2.0%+15)
Setup
- Unpack and Inspect: Carefully remove all components from the packaging and inspect for any damage. Refer to the 'Package Contents' section to ensure all items are present.
- Install Receiver Battery: The Wire Tracker Receiver requires one 9V battery (not included). Open the battery compartment on the back of the receiver and insert the 9V battery, observing correct polarity.
- Charge Host Unit: The KKNOON K618 Host Unit has a built-in rechargeable battery. Connect the host unit to a USB power source using the provided USB recharging cable. A full charge typically takes about 3 hours and provides approximately 8 hours of operation.

Operating Instructions
The KKNOON K618 offers multiple testing modes. Use the 'MODE' button on the host unit to switch between functions and the rotary switch on the receiver to select tracing modes.
1. Cable Tracing Function
This function helps locate a specific cable among many.
- Connect one end of the cable to be traced to the 'MAIN' port on the host unit.
- Turn on the host unit and select the 'SCAN' mode.
- Turn on the Wire Tracker Receiver.
- Adjust the receiver's rotary switch to select the desired tracing mode:
- Analogue Tracing: The receiver emits an audible tone. The red light on the receiver indicates this mode.
- Digital Tracing: Provides a more precise digital signal. The blue light on the receiver indicates this mode.
- Vibration Tracing: Offers noiseless tracing with a blue light flash on the receiver.
- Move the receiver along the cables. The signal strength will increase as you approach the target cable.


2. Network Cable Length Measurement
This function measures the length of various metal cables, including network cables, telephone lines, and BNC cables, up to 500 meters.
- Ensure the cable to be measured is disconnected from any network devices.
- Connect one end of the cable to the 'LENGTH' port on the host unit.
- Turn on the host unit and select the 'LENGTH' mode.
- The display will show the cable length in meters. It will also indicate if there is an 'Open circuit', 'Short circuit', or if the cable is 'Normal'.

3. POE Test
The POE test function checks the cable mapping, polarity, and voltage of Power over Ethernet network switches.
- Connect the network cable from the POE switch to the 'MAIN' port on the host unit.
- Turn on the host unit and select the 'POE' mode.
- The display will show the POE voltage and identify which pins are providing power. A digital flicker indicates a positive reading.


4. ID Pairing Function
Use the remote ID mapping tools to identify multiple cable runs efficiently.
- Connect the remote ID mapping tools (ID 1, ID 2, ID 3) to the far ends of the cables you wish to identify.
- Connect the main unit to the near end of a cable.
- Turn on the host unit and select the 'ID' mode.
- The display will show the ID number corresponding to the connected remote unit, allowing you to map and identify cables in one step.

5. Switch Port Flicker
This alignment function helps to directly find network wires by causing the corresponding switch port light to blink.
- Connect the main unit to a network cable connected to a switch.
- Turn on the host unit and select the 'TEST' mode.
- When using the alignment function, the sequence light corresponding to the switch will blink once every 2 seconds, helping to identify the connected network wire.

6. Multimeter Functions
The K618 integrates a full-featured digital multimeter (DMM) for various electrical measurements.
- Connect the multimeter probes to the appropriate ports on the host unit (COM, VΩHzLive, 10A MAX).
- Turn on the host unit and select the 'DMM' mode.
- Use the 'MODE' button to cycle through different measurement types:
- DC Voltage: Measure direct current voltage.
- AC Voltage: Measure alternating current voltage.
- DC Current: Measure direct current.
- AC Current: Measure alternating current.
- Resistance: Measure electrical resistance.
- Continuity: Test for continuity (audible beep if resistance is below 50Ω).
- Diode: Test diode functionality.
- Temperature: Measure temperature using the provided K-type temperature probe.
- NCV (Non-Contact Voltage): Detect AC voltage without direct contact.

User Tips
- Always ensure the host unit is fully charged before starting extensive testing to avoid interruptions.
- For accurate cable length measurements, ensure the cable is completely disconnected from all devices.
- When using the wire tracker, start with analogue tracing to get a general idea, then switch to digital or vibration mode for more precise identification, especially in noisy environments.
- Keep the remote ID mapping tools organized and labeled to streamline multi-cable identification tasks.
- Refer to the detailed instructions in the included user manual for specific measurement ranges and safety precautions for each multimeter function.
Maintenance
- Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Battery Care: For the host unit, recharge regularly. If storing for an extended period, charge it to about 50% and recharge every few months. For the receiver, remove the 9V battery if the device will not be used for a long time to prevent leakage.
- Storage: Store the device and its accessories in the provided storage bag in a cool, dry place, away from direct sunlight and extreme temperatures.
- Safety Warning: To avoid electrical shock, always remove all connections before replacing the battery or fuse, or opening the device case. Refer to the user manual for specific battery and fuse specifications.

Troubleshooting
- Device Not Powering On: Ensure the host unit is charged or the receiver has a fresh 9V battery installed correctly.
- Inaccurate Length Measurement: Verify that the cable is completely disconnected from all network devices and that the connection to the 'LENGTH' port is secure.
- No Signal During Tracing: Check that both the host unit and receiver are powered on and in the correct mode. Ensure the cable is properly connected to the host unit. Adjust the sensitivity on the receiver if available.
- Multimeter Readings are Off: Ensure probes are correctly inserted into the appropriate ports for the selected measurement type. Check probe integrity for any damage.
- Display Issues: If the display is dim or flickering, the battery may be low. Recharge the host unit or replace the receiver battery.
Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact details provided by your retailer or the manufacturer. Keep your purchase receipt as proof of purchase for any warranty claims.