1. Introduction
The BSIDE A1X Digital Multimeter is a compact, intelligent testing device designed for a wide range of electrical measurements. Its portable pen-type design makes it easy to carry and use in various environments. This manual provides essential information for safe and effective operation of your multimeter.
Key features include:
- Automatic identification of measurement signals (Auto Range).
- Measures AC/DC voltage, resistance, capacitance, continuity, frequency, and diode.
- Non-Contact Voltage (NCV) detection and Live/Neutral wire recognition.
- Large LCD color display with red and green backlight for clear readings.
- Built-in LED flashlight for use in dark conditions.
- Rechargeable 400mAh Li-ion battery with Type-C charging.
- Automatic shutdown after 15 minutes of inactivity to conserve battery.
2. Safety Information
Please read and understand all safety warnings and operating instructions before using this multimeter. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always ensure the multimeter is in the correct measurement mode before connecting to a circuit.
- Do not attempt to measure voltages or currents exceeding the specified maximum limits.
- Exercise extreme caution when working with live electrical circuits.
- Inspect test leads for damage before each use. Do not use if insulation is damaged.
- Do not operate the multimeter if it appears damaged or is not functioning properly.
- Keep hands and fingers behind the probe barriers during measurements.
- Avoid using the device in wet environments or during electrical storms.
- Ensure the battery is adequately charged for accurate readings.
3. Product Overview
The BSIDE A1X is designed for user-friendly operation with clearly labeled components.
Components:
- Non-contact voltage sensor: Detects AC voltage without direct contact.
- Flashlight: Provides illumination in dark work areas.
- Display Screen: Large LCD for showing measurement readings and mode indicators.
- Function buttons: Used to select specific measurement modes (e.g., Capacitance, Diode).
- Flashlight/Backlight switch button: Toggles the flashlight and display backlight.
- Power button: Turns the device on/off.
- Input terminals: For connecting test leads (INPUT, COM, INPUT).
4. Setup
4.1 Charging the Battery
The BSIDE A1X features a built-in 400mAh lithium-ion battery. To charge the device:
- Locate the Type-C charging port on the multimeter.
- Connect the provided Type-C cable to the multimeter and a suitable USB power source (e.g., computer, USB wall adapter).
- The charging indicator will illuminate, typically red, during charging.
- Once fully charged, the indicator may change color or turn off.
4.2 Connecting Test Leads
For most measurements, you will need to connect the test leads:
- Insert the black test lead into the "COM" (Common) input terminal.
- Insert the red test lead into the "INPUT" terminal (for voltage, resistance, capacitance, diode, continuity, and frequency measurements).
5. Operating Instructions
5.1 Power On/Off
Press the Power button to turn the multimeter on. The device will automatically enter Auto Mode. Press and hold the Power button to turn it off.
5.2 Auto Mode Selection
In Auto Mode, the multimeter automatically identifies and measures voltage, resistance, continuity, and frequency. This simplifies operation as you don't need to manually select the measurement type.
5.3 Manual Mode Selection
To select specific measurement functions manually, press the "AUTO SEL" button repeatedly to cycle through available modes:
- AC Voltage (V~): For alternating current voltage measurements.
- DC Voltage (V=): For direct current voltage measurements.
- Resistance (Ω): For measuring electrical resistance.
- Capacitance (μF): For measuring capacitance.
- Continuity ())) ): For checking circuit continuity (buzzer sounds if resistance is <50Ω).
- Diode (->|): For testing diodes (measures diodes within 3.0V).
- NCV (Non-Contact Voltage): For detecting AC voltage without physical contact.
- LIVE: For Live/Neutral wire identification.
5.4 AC/DC Voltage Measurement
The multimeter can automatically measure AC or DC voltage in Auto Mode. For manual selection, press "AUTO SEL" until the desired voltage mode (V~ for AC, V= for DC) is displayed.
- Connect the red test lead to the positive side of the circuit and the black test lead to the negative side or ground.
- Read the voltage value on the display. The backlight will turn red for high voltage alerts.
5.5 Resistance Measurement
In Auto Mode, the multimeter can measure resistance. For manual selection, press "AUTO SEL" until the Ω symbol is displayed.
- Ensure the circuit is de-energized before measuring resistance.
- Connect the test leads across the component to be measured.
- Read the resistance value on the display.
5.6 Capacitance Measurement
Press "AUTO SEL" until the μF symbol is displayed.
- Before measuring capacitance, please discharge the capacitor first.
- Connect the test leads across the capacitor.
- Read the capacitance value on the display.
5.7 Continuity Test
Press "AUTO SEL" until the continuity symbol ())) ) is displayed.
- Ensure the circuit is de-energized.
- Connect the test leads across the circuit or component.
- If the resistance is less than 50Ω, the buzzer will sound, indicating continuity.
5.8 Diode Test
Press "AUTO SEL" until the diode symbol (->|) is displayed.
- Ensure the circuit is de-energized.
- Connect the red test lead to the anode and the black test lead to the cathode of the diode.
- The display will show the forward voltage drop (for diodes within 3.0V). Reverse the leads to check for open circuit.
5.9 NCV (Non-Contact Voltage) Detection
Press "AUTO SEL" until "NCV" is displayed. This mode allows detection of AC voltage without direct contact.
- Place the tip of the multimeter near the conductor or outlet.
- The device will emit an audible alarm and the display backlight will change color (red) if AC voltage is detected.
5.10 Live/Neutral Wire Check
Press "AUTO SEL" until "LIVE" is displayed. This function helps distinguish between live and neutral wires.
- Insert the tip of the multimeter into the socket or near the wire.
- The device compares the strength of the detected voltage signal. A stronger signal (red backlight) indicates a live wire, while a weaker or no signal (green backlight) indicates a neutral wire.
5.11 Flashlight and Backlight
Press the Flashlight/Backlight switch button to toggle the built-in LED flashlight. This is useful for illuminating dark work areas. The display also features a backlight that changes color (red/green) to indicate different states or alerts.
6. Specifications
| Function | Range | Resolution | Accuracy |
|---|---|---|---|
| DC Voltage | 0-520V (DC Mode) 0.5-520V (Auto Mode) |
0.001V | ±(0.8%+3) |
| AC Voltage | 0-520V (AC Mode) 0.5-520V (Auto Mode) |
0.001V | ±(1.2%+5) |
| Resistance | 0.0Ω-19.99MΩ | 1Ω | ±(1.2%+5) |
| Capacitance | 1nF-1999μF | 0.01nF | ±(3.5%+8) |
| Continuity | If the resistance <50Ω the buzzer sounds | ||
| Diode | Measure diodes within 3.0V | ||
| V~Alert (NCV) | Live wire check supported | ||
| Auto power off | 15 minutes | ||
| Flashlight | Supported | ||
| Power | Built-in 400mA 3.7V lithium battery | ||
| Size | 146 * 44 * 25.2mm | Weight | 73g |
7. Maintenance
- Cleaning: Use a soft, damp cloth to clean the multimeter casing. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Battery Care: Recharge the built-in lithium battery regularly, even if not in frequent use, to maintain its lifespan. Avoid fully discharging the battery for extended periods.
- Test Leads: Periodically check the test leads for any signs of wear, cuts, or damage to the insulation. Replace damaged leads immediately.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Multimeter does not power on. | Low or discharged battery. | Charge the battery using the provided Type-C cable. |
| Inaccurate readings. | Incorrect mode selection, damaged test leads, or environmental factors. | Ensure correct mode is selected. Check test leads for damage. Avoid extreme temperatures or humidity. |
| Buzzer does not sound during continuity test. | Resistance is too high or circuit is open. | Verify the circuit is complete and resistance is below 50Ω. |
| NCV detection not working. | No AC voltage present, or device not close enough to the source. | Ensure AC voltage is present. Move the device closer to the conductor. |
9. User Tips
- The auto-ranging feature is very convenient for general use, but for specific measurements, manually selecting the mode can sometimes provide more stable readings.
- Always double-check your connections before taking a measurement, especially when dealing with live circuits.
- The compact size makes it ideal for carrying in a tool belt or pocket, ensuring it's always handy for quick checks.
10. Warranty and Support