1. Introduction

The BSIDE A1X Digital Multimeter is a compact, intelligent testing device designed for a wide range of electrical measurements. Its portable pen-type design makes it easy to carry and use in various environments. This manual provides essential information for safe and effective operation of your multimeter.

Key features include:

  • Automatic identification of measurement signals (Auto Range).
  • Measures AC/DC voltage, resistance, capacitance, continuity, frequency, and diode.
  • Non-Contact Voltage (NCV) detection and Live/Neutral wire recognition.
  • Large LCD color display with red and green backlight for clear readings.
  • Built-in LED flashlight for use in dark conditions.
  • Rechargeable 400mAh Li-ion battery with Type-C charging.
  • Automatic shutdown after 15 minutes of inactivity to conserve battery.
BSIDE A1X Digital Multimeter with test leads and display showing neutral and live wire detection
Figure 1: BSIDE A1X Digital Multimeter with test leads, demonstrating neutral and live wire detection.

2. Safety Information

Please read and understand all safety warnings and operating instructions before using this multimeter. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always ensure the multimeter is in the correct measurement mode before connecting to a circuit.
  • Do not attempt to measure voltages or currents exceeding the specified maximum limits.
  • Exercise extreme caution when working with live electrical circuits.
  • Inspect test leads for damage before each use. Do not use if insulation is damaged.
  • Do not operate the multimeter if it appears damaged or is not functioning properly.
  • Keep hands and fingers behind the probe barriers during measurements.
  • Avoid using the device in wet environments or during electrical storms.
  • Ensure the battery is adequately charged for accurate readings.

3. Product Overview

The BSIDE A1X is designed for user-friendly operation with clearly labeled components.

Diagram of BSIDE A1X Multimeter showing parts: Non-contact voltage sensor, Flashlight, Display Screen, Function button, Capacitance mode button, Diode mode button, Flashlight/Backlight switch button, Power button, Negative input terminal.
Figure 2: Front view of the BSIDE A1X Multimeter with labeled components.

Components:

  • Non-contact voltage sensor: Detects AC voltage without direct contact.
  • Flashlight: Provides illumination in dark work areas.
  • Display Screen: Large LCD for showing measurement readings and mode indicators.
  • Function buttons: Used to select specific measurement modes (e.g., Capacitance, Diode).
  • Flashlight/Backlight switch button: Toggles the flashlight and display backlight.
  • Power button: Turns the device on/off.
  • Input terminals: For connecting test leads (INPUT, COM, INPUT).

4. Setup

4.1 Charging the Battery

The BSIDE A1X features a built-in 400mAh lithium-ion battery. To charge the device:

  1. Locate the Type-C charging port on the multimeter.
  2. Connect the provided Type-C cable to the multimeter and a suitable USB power source (e.g., computer, USB wall adapter).
  3. The charging indicator will illuminate, typically red, during charging.
  4. Once fully charged, the indicator may change color or turn off.
Image showing the multimeter being charged via a Type-C cable.
Figure 3: Multimeter connected for charging via Type-C cable.

4.2 Connecting Test Leads

For most measurements, you will need to connect the test leads:

  1. Insert the black test lead into the "COM" (Common) input terminal.
  2. Insert the red test lead into the "INPUT" terminal (for voltage, resistance, capacitance, diode, continuity, and frequency measurements).

5. Operating Instructions

5.1 Power On/Off

Press the Power button to turn the multimeter on. The device will automatically enter Auto Mode. Press and hold the Power button to turn it off.

5.2 Auto Mode Selection

In Auto Mode, the multimeter automatically identifies and measures voltage, resistance, continuity, and frequency. This simplifies operation as you don't need to manually select the measurement type.

Multimeter display showing 'Auto' mode and icons for various measurements like voltage, resistance, continuity, frequency, diode, and NCV.
Figure 4: Auto Mode display with various measurement icons.

5.3 Manual Mode Selection

To select specific measurement functions manually, press the "AUTO SEL" button repeatedly to cycle through available modes:

  • AC Voltage (V~): For alternating current voltage measurements.
  • DC Voltage (V=): For direct current voltage measurements.
  • Resistance (Ω): For measuring electrical resistance.
  • Capacitance (μF): For measuring capacitance.
  • Continuity ())) ): For checking circuit continuity (buzzer sounds if resistance is <50Ω).
  • Diode (->|): For testing diodes (measures diodes within 3.0V).
  • NCV (Non-Contact Voltage): For detecting AC voltage without physical contact.
  • LIVE: For Live/Neutral wire identification.
Icons representing various measurement functions: T-RMS, 1999 counts, DC voltage, AC voltage, Capacitance, NCV, Resistance, Diode, Live Wire, Continuity, Battery Test, Flashlight, Auto Range, Backlight, Battery undervoltage.
Figure 5: Icons for various measurement functions.

5.4 AC/DC Voltage Measurement

The multimeter can automatically measure AC or DC voltage in Auto Mode. For manual selection, press "AUTO SEL" until the desired voltage mode (V~ for AC, V= for DC) is displayed.

  1. Connect the red test lead to the positive side of the circuit and the black test lead to the negative side or ground.
  2. Read the voltage value on the display. The backlight will turn red for high voltage alerts.
Multimeter measuring AC voltage from a circuit breaker, showing a red display with a reading of 380.0V.
Figure 6: Example of AC Voltage measurement.
Play video
Watch video online
Video 1: Demonstration of voltage and resistance measurement using the BSIDE A1X multimeter.

5.5 Resistance Measurement

In Auto Mode, the multimeter can measure resistance. For manual selection, press "AUTO SEL" until the Ω symbol is displayed.

  1. Ensure the circuit is de-energized before measuring resistance.
  2. Connect the test leads across the component to be measured.
  3. Read the resistance value on the display.

5.6 Capacitance Measurement

Press "AUTO SEL" until the μF symbol is displayed.

  1. Before measuring capacitance, please discharge the capacitor first.
  2. Connect the test leads across the capacitor.
  3. Read the capacitance value on the display.
Multimeter performing a capacitance test on a circuit board, showing a reading of 0.680 μF.
Figure 7: Capacitance test on an electronic component.

5.7 Continuity Test

Press "AUTO SEL" until the continuity symbol ())) ) is displayed.

  1. Ensure the circuit is de-energized.
  2. Connect the test leads across the circuit or component.
  3. If the resistance is less than 50Ω, the buzzer will sound, indicating continuity.

5.8 Diode Test

Press "AUTO SEL" until the diode symbol (->|) is displayed.

  1. Ensure the circuit is de-energized.
  2. Connect the red test lead to the anode and the black test lead to the cathode of the diode.
  3. The display will show the forward voltage drop (for diodes within 3.0V). Reverse the leads to check for open circuit.
Multimeter performing a diode test on a circuit board, showing a reading of 0.080V.
Figure 8: Diode test on an electronic component.

5.9 NCV (Non-Contact Voltage) Detection

Press "AUTO SEL" until "NCV" is displayed. This mode allows detection of AC voltage without direct contact.

  1. Place the tip of the multimeter near the conductor or outlet.
  2. The device will emit an audible alarm and the display backlight will change color (red) if AC voltage is detected.

5.10 Live/Neutral Wire Check

Press "AUTO SEL" until "LIVE" is displayed. This function helps distinguish between live and neutral wires.

  1. Insert the tip of the multimeter into the socket or near the wire.
  2. The device compares the strength of the detected voltage signal. A stronger signal (red backlight) indicates a live wire, while a weaker or no signal (green backlight) indicates a neutral wire.
Multimeter detecting a neutral wire (green display) and a live wire (red display) in an electrical outlet.
Figure 9: Live/Neutral Wire Check demonstration.
Comparison of voltage test with test leads and non-contact voltage detection.
Figure 10: Measurement Circuit showing both contact voltage test and non-contact voltage detection.

5.11 Flashlight and Backlight

Press the Flashlight/Backlight switch button to toggle the built-in LED flashlight. This is useful for illuminating dark work areas. The display also features a backlight that changes color (red/green) to indicate different states or alerts.

Multimeter with its bright LED flashlight illuminated, showing it can be used in various lighting conditions.
Figure 11: Bright LED Flashlight in use.
Multimeter display showing red and green backlights, indicating different measurement states or alerts.
Figure 12: Red & Green Backlight feature.

6. Specifications

Function Range Resolution Accuracy
DC Voltage 0-520V (DC Mode)
0.5-520V (Auto Mode)
0.001V ±(0.8%+3)
AC Voltage 0-520V (AC Mode)
0.5-520V (Auto Mode)
0.001V ±(1.2%+5)
Resistance 0.0Ω-19.99MΩ 1Ω ±(1.2%+5)
Capacitance 1nF-1999μF 0.01nF ±(3.5%+8)
Continuity If the resistance <50Ω the buzzer sounds
Diode Measure diodes within 3.0V
V~Alert (NCV) Live wire check supported
Auto power off 15 minutes
Flashlight Supported
Power Built-in 400mA 3.7V lithium battery
Size 146 * 44 * 25.2mm Weight 73g
Table of specifications for the BSIDE A1X Multimeter, detailing functions, ranges, resolutions, and accuracies for DC Voltage, AC Voltage, Resistance, Capacitance, Continuity, Diode, V~Alert, Auto power off, Flashlight, Power, Size, and Weight.
Figure 13: Detailed product specifications.
Diagram showing the dimensions of the BSIDE A1X Multimeter: 5.7 inches long, 1.7 inches wide, 0.9 inches thick, with a 2.1 inch display.
Figure 14: Product dimensions.

7. Maintenance

  • Cleaning: Use a soft, damp cloth to clean the multimeter casing. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: Recharge the built-in lithium battery regularly, even if not in frequent use, to maintain its lifespan. Avoid fully discharging the battery for extended periods.
  • Test Leads: Periodically check the test leads for any signs of wear, cuts, or damage to the insulation. Replace damaged leads immediately.

8. Troubleshooting

Problem Possible Cause Solution
Multimeter does not power on. Low or discharged battery. Charge the battery using the provided Type-C cable.
Inaccurate readings. Incorrect mode selection, damaged test leads, or environmental factors. Ensure correct mode is selected. Check test leads for damage. Avoid extreme temperatures or humidity.
Buzzer does not sound during continuity test. Resistance is too high or circuit is open. Verify the circuit is complete and resistance is below 50Ω.
NCV detection not working. No AC voltage present, or device not close enough to the source. Ensure AC voltage is present. Move the device closer to the conductor.

9. User Tips

  • The auto-ranging feature is very convenient for general use, but for specific measurements, manually selecting the mode can sometimes provide more stable readings.
  • Always double-check your connections before taking a measurement, especially when dealing with live circuits.
  • The compact size makes it ideal for carrying in a tool belt or pocket, ensuring it's always handy for quick checks.

10. Warranty and Support

For any issues, technical support, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.