Raycus RFL-P20QS/P30QS

Contents

Raycus Fiber Laser Q-switched Pulse RFL-P20QS/P30QS User Manual

Model: RFL-P20QS/P30QS

Manufacturer: Wuhan Raycus Fiber Laser Technologies CO., LTD.

1. Introduction

The Raycus 20-100W Q-Switched Pulse Fiber Laser Series is specifically designed for high-speed and efficient laser marking and micromachining applications. This series of pulsed lasers offers high peak power, high single-pulse energy, and an optional spot diameter, making it suitable for various fields such as marking, precision processing, and graphic engraving of non-metal, gold, silver, copper, and aluminum with high anti-reflection characteristics, as well as stainless steel materials without altitude stress resistance. Its marking process provides lower cost and more stable performance compared to traditional lasers.

1.1. Key Features

  • Highly stable laser output
  • High single-pulse energy
  • High marking efficiency
  • Short pulse setup time
  • High reliability
  • Maintenance-free operation

1.2. Applications

This fiber laser is widely used in various marking and precision machining applications. Examples include engraving on non-metallic materials, gold, silver, copper, aluminum, and stainless steel. The versatility and stable performance make it ideal for industrial use.

Examples of laser applications including engraving on a charger, keychain, wood, and flask.
Figure 1: Examples of applications for the Raycus Fiber Laser.

2. Safety Information

Before operating this product, please read and understand this user manual and all provided information. This manual contains important product operation, safety, and other information for your reference. To ensure safe operation and optimal product performance, please follow all warnings and instructions.

2.1. General Safety Precautions

  • The Raycus pulsed fiber laser is a Class IV laser product.
  • Before turning on the 24VDC power, ensure correct power connection and polarity. Incorrect connection can damage the laser.
  • The laser emits radiation in the 1060-1085nm wavelength range with power exceeding 20W or 30W. Avoid eye and skin exposure to direct or scattered radiation from the output.
  • Do not open the machine. There are no user-serviceable parts or components inside. All maintenance and repairs must be performed by Raycus personnel.
  • Never look directly into the output head. Always wear appropriate laser safety glasses during operation.
  • Ensure the grounding wire is reliably connected when using the laser.
  • The laser's output head is connected to the optical cable. Handle the output head carefully to prevent dust or other contamination. When the laser is not emitting light, cover the optical isolator with a protective cap to prevent dust.
  • If the laser is not used according to the methods specified in this manual, its protective functions may be weakened. Therefore, the product must be used in a normal environment.
  • Do not install the output collimator when the laser is running.
  • The laser has three fans at the rear for heat dissipation. Ensure sufficient airflow for cooling. The fans operate by blowing air from the fan position towards the laser output cable. Maintain at least 10cm of ventilation space around the front and rear of the laser. If the cabinet has its own cooling fans, ensure their airflow direction is not opposite to the laser's fans.
  • A sudden power interruption can severely damage the laser. Maintain a stable power supply.
Laser warning label showing 'Be careful, Avoid direct laser irradiation'.
Figure 2: Safety Warning Label.

3. Specifications

The following table details the technical parameters for the RFL-P20QS and RFL-P30QS pulsed fiber laser series.

Table of specifications for RFL-P20QS and RFL-P30QS models.
Figure 3: Technical Specifications for RFL-P20QS and RFL-P30QS.
Table 1: RFL-P20QS/P30QS Pulsed Fiber Laser Parameters
ParameterRFL-P20QSRFL-P30QS
Wavelength (nm)1060~10851060~1085
PolarizationRandomRandom
Optical IsolatorYesYes
Nominal Average Output Power (W)≥20≥30
Single Pulse Energy (mJ)0.66@30kHz0.75@40kHz
Beam Quality (M²)<1.6<1.6
Beam Diameter (mm)6-86-8
Pulse Duration (ns)110-140@30kHz130-150@40kHz
Pulse Repetition Rate (kHz)30-6040-60
Output Power Tunability (%)10-10010-100
Output Fiber Cable Length (m)33
Working Voltage (VDC)24±124±1
Power Consumption (20°C) (W)<150@20°C<200@20°C
CoolingForced Air CooledForced Air Cooled
Dimension WxDxH (mm)290*215*95290*215*95
Operating Temperature (°C)0°C ~ 40°C0°C ~ 40°C
Store Temperature (°C)-10°C ~ 60°C-10°C ~ 60°C
Humidity (%)30% ~ 85%30% ~ 85%

4. Installation

4.1. Dimensions

The following diagrams illustrate the dimensions of the laser unit and its optical isolator.

Main unit dimension diagram showing length, width, and height.
Figure 4: Laser Unit Dimensions (Unit: mm).
Detailed dimension diagram of the main unit and optical isolator, including various measurements.
Figure 5: Detailed Dimensions of Laser Unit and Optical Isolator (Unit: mm).

4.2. Installation Procedure

  1. Securely fix the laser unit to a bracket, ensuring good ventilation.
  2. Connect the power cable to a 24VDC power supply. Ensure the power supply can provide sufficient output power. Pay attention to the polarity: brown wire for positive (+), blue wire for negative (-), and yellow-green wire for protective ground (PE).
  3. Confirm that the external controller's interface matches the laser. Connect the control cable to the laser's control interface and secure it.
  4. Ensure the bending radius of the output fiber cable is no less than 15cm.
  5. The laser has three fans at the rear for heat dissipation. Ensure sufficient airflow for cooling. The fans operate by blowing air from the fan position towards the laser output cable. Maintain at least 10cm of ventilation space around the front and rear of the laser. If the cabinet has its own cooling fans, ensure their airflow direction is not opposite to the laser's fans.
Rear view of the laser source showing power input and DB25 connector.
Figure 6: Rear Panel with Power and Control Connections.
Wiring diagram for power and control signals, showing 24V power supply and DB25 control interface.
Figure 7: Electrical Connection Diagram.

5. Control Interface

The DB25 connector on the rear panel of the power module serves as the interface for connecting to the control system (e.g., marking machine) and the laser system. Ensure reliable connection before operation. The pin definitions are as follows:

DB25 pinout diagram showing pin numbers 1-13 and 14-25.
Figure 8: DB25 Control Interface Pinout.
Table 2: DB25 Control Port Pin Definitions
PIN No.NameDescription
1-8 (D0-D7)Power Setting8-bit Parallel port; D0 is minimum bit and D7 is maximum bit; Range: 0-255 (hexadecimal 0x00-0xFF); 0 is minimum power and 255 is maximum power.
10,14GroundDigital GND.
11,12,16,21Laser alarms statusSee alarm codes in the table below.
17VCCPower supply input for independent operation of the guide laser and PCB. Maximum current consumption is 0.1A.
18EEEmission Enable (EE) signal. HIGH: Emission Enable LOW or disconnected: Emission Disable.
19EMEmission Modulation (EM) input HIGH (> 3V): Emission ON LOW or disconnected (<1V): Emission OFF
20SyncPulse Repetition Rate (Synchronization) input, square wave.
22Guide Laser signalGuide Laser (red diode) ON/OFF input.
9,13,15,23,24,25Obligate PINReserved for Raycus only.

5.1. Power Setting (Pins 1-8)

Pins 1-8 (TTL level) are used for power setting. The combination of these 8 pins controls the current of the pump laser diode, thereby controlling the laser's output power. A range of 0-255 can be set, corresponding to 0% to 100% power output (actual optical power output may not be linear with these settings).

Table 3: Power Signal Definition Examples
SettingPin 1Pin 2Pin 3Pin 4Pin 5Pin 6Pin 7Pin 8Current (%)
100000001~50%
200000011~75%
300000111~87.5%
400001111~93.75%
500011111~100%

5.2. Alarm Signals (Pins 11, 12, 16, 21)

The laser provides alarm signals through these pins. When the laser detects abnormal conditions (e.g., abnormal output, voltage, or current), it enters a self-locking state to protect itself and stops receiving commands. To reset, restart the device.

Table 4: Alarm Signal Definition
Pin 12Pin 11Pin 16Pin 21Laser Alarm Item
XLowLowLowLaser temperature alarm
XLowHighHighNormal
XHighLowLowLaser status abnormal alarm
XHighHighHighMaster oscillator alarm

Note 1: The output alarm signals are powered by the DB25 interface. Ensure Pin 17 of the DB25 interface is connected to a +5V power supply. If not connected or if the DB25 interface has poor contact, even if the laser is not alarming, the alarm signals will remain low, and the board may display a laser fault.

Note 2: Actual internal voltage/current detection abnormality. Due to varying marking card support, other content may be displayed, such as "POWER ERR" when using the Golden Orange marking card.

Note 3: Actual laser output detection abnormality. Due to varying marking card support, other content may be displayed, such as "SYSTEM ERR" when using the Golden Orange marking card.

6. Operation Procedure

6.1. Pre-Operation Checks

  • Check the laser's appearance for any abnormalities. Ensure the output fiber is not bent or detached.
  • Verify that the signal cable between the marking machine and the laser is properly connected.

6.2. Startup Procedure

  1. Turn on the marking machine power and the laser power simultaneously, or turn on the marking machine first, then the laser. Wait 10 seconds after the laser powers on before proceeding with further operations.
  2. After the marking machine starts, check its marking operation steps.
  3. Once the equipment starts normally, for the initial laser test, set the power to zero without marking. Then, draw a square and continuously mark, gradually increasing the power from 0 to 100%. Observe the laser output with a ceramic laser conversion sheet; it should gradually become stronger. If not, turn off the machine and check. Once normal operation is confirmed, you can proceed with marking as per standard marking machine procedures.

6.3. Precautions During Marking

  • The marking machine's frequency range should not exceed 20kHz~60kHz.
  • Avoid adjusting the modulation frequency during marking.
  • When shutting down, always stop marking first, set the power to zero, and then turn off the laser power.
Video 1: Raycus Fiber Laser Product Overview. This video demonstrates the physical appearance and various angles of the laser source.

7. Maintenance

The Raycus Fiber Laser contains no user-serviceable parts. All maintenance and repairs must be performed by qualified Raycus personnel. Attempting to open or repair the unit yourself will void the warranty and may expose you to hazardous laser radiation.

7.1. Cleaning

  • Keep the laser unit clean and free from dust.
  • Regularly check the output head for any dust or contamination. Use specialized lens paper for cleaning the output lens if necessary.
  • Ensure the cooling vents are clear of obstructions to maintain proper airflow.

8. Troubleshooting

If the laser experiences issues, refer to the alarm signals and general checks below. For any persistent problems, contact Raycus technical support.

8.1. Common Issues and Solutions

  • No Laser Output / Weak Output:
    • Check power supply connection (24VDC) and polarity.
    • Verify control cable connection to the marking machine.
    • Ensure power setting (Pins 1-8) is correctly configured and not set to zero.
    • Check for alarm signals (Pins 11, 12, 16, 21). Refer to Table 4 for alarm definitions.
    • Inspect the output fiber for bends, damage, or contamination.
  • Alarm Indication:
    • If a temperature alarm is indicated, ensure proper ventilation and cooling. Clear any obstructions from the fans.
    • If a laser status abnormal alarm or master oscillator alarm occurs, restart the device. If the problem persists, contact support.
    • Ensure Pin 17 of the DB25 is correctly connected to +5V power, as incorrect connection can lead to false alarm readings.
  • System Error Messages:
    • Error messages like "POWER ERR" or "SYSTEM ERR" on the marking card often indicate internal voltage/current or output detection abnormalities. Refer to the alarm signal table and contact support if necessary.

9. Warranty and Support

9.1. General Warranty

Raycus warrants products manufactured according to order or specifications against defects in materials and workmanship under normal use. The standard warranty period for the Raycus Fiber Laser is 2 years. Raycus reserves the right to repair or replace, at its discretion, any product found to be defective within the warranty period. Only products with specific issues are covered by free warranty; Raycus reserves the right to charge for products found to be in normal working condition.

9.2. Warranty Limitations

The warranty does not cover damage to the product or its components (including optical cables) caused by unauthorized tampering, opening, disassembly, incorrect installation, or modification by non-Raycus personnel. Damage resulting from misuse, negligence, accidents, use beyond specifications, improper installation and maintenance, or failure to follow instructions and warnings in the user manual will void the warranty. Customers are responsible for understanding and operating the product according to the user manual and operating procedures. Damage caused by incorrect operation is not covered by the warranty. Accessories and optical cables are not covered by the warranty.

Within the warranty period, the buyer must submit a written request within 31 days of discovering a product issue. This warranty does not involve third parties, including the specified buyer, end-user, or customer, nor does it include parts, equipment, or other products not manufactured by Raycus.

9.3. Technical Support

For technical assistance, troubleshooting, or warranty claims, please contact Raycus technical support. When returning items for repair or replacement, ensure they are properly packaged. If goods are received damaged, immediately notify the carrier in writing.

A detailed user manual in PDF format is available for download: Raycus Fiber Laser User Manual (PDF)

10. User Tips

  • Stable Environment: Always operate the laser in a stable environment with consistent power supply and good ventilation to prevent unexpected shutdowns or damage.
  • Regular Cleaning: Periodically check and clean the optical components, especially the output lens, using appropriate materials to maintain optimal performance and prevent power degradation.
  • Proper Grounding: Ensure the laser system is always properly grounded to prevent electrical hazards and ensure stable operation.

11. Frequently Asked Questions (FAQ)

Q: For what purpose can I utilize this item?
A: This item can be used for Q-switched Pulse applications, primarily in Fiber Marking Machines for industrial marking and micromachining.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.