1. Introduction
This manual provides detailed instructions for the proper use and maintenance of your KKMOON PH818 Professional pH Water Quality Tester. This pen-type pH meter is designed for high-precision measurement of pH levels and temperature in various solutions. Featuring automatic temperature compensation and a replaceable sensor, it offers accurate and stable readings for a wide range of applications.
2. Package Contents
Please check the package contents upon receipt to ensure all items are present:
- 1 x KKMOON PH818 pH Meter (Batteries not included)
- 1 x Storage Bag
- 1 x User Manual (this document)
3. Key Features
- Simultaneous measurement of pH level and temperature.
- Data hold function for convenient reading.
- Compact, lightweight, and portable pen-type design.
- Switchable backlight and large LCD display for clear visibility.
- Replaceable pH sensor probe with an insert-type design for easy replacement.
- Automatic Temperature Compensation (ATC) for accurate readings across varying temperatures (0℃ ~ 70℃).
- 2-point automatic calibration.
- IP65 fully waterproof design for durability.
- Suitable for a wide range of applications including water sources, soil-free growing, aquariums, hydroponics, laboratories, spas, and swimming pools.
4. Specifications
| Parameter | Value |
|---|---|
| Material | ABS Plastic |
| Color | Grey |
| pH Testing Range | 0.00~14.00pH |
| Temperature Testing Range | 0℃ ~ 60℃ |
| pH Resolution | 0.01pH |
| pH Accuracy | ±0.05pH |
| pH Repeatability | ± 0.01 |
| Operating Temperature | 0℃ ~ 50℃, ≤80%RH |
| Automatic Temperature Compensation | 0℃ ~ 70℃ |
| Calibration | 2 Points Automatic Calibration |
| Power | 2 * 1.5V AAA Battery (NOT Included) |
| Item Size | Approx. 175 * 45 * 45mm / 6.9 * 1.8 * 1.8in |
| Item Weight | Approx. 87g / 3.1oz |
5. Setup
5.1 Battery Installation
- Unscrew the battery compartment cover located at the top of the meter.
- Insert two (2) 1.5V AAA batteries, ensuring correct polarity (+/-).
- Securely replace the battery compartment cover.
5.2 Initial Preparation
- Remove the protective cap from the electrode.
- Rinse the electrode with distilled water and gently blot dry with a clean tissue. Do not rub.
- The electrode should be conditioned by soaking it in pH 7.0 buffer solution for at least 30 minutes before first use or after prolonged storage.
6. Operation
6.1 Taking a Measurement
- Press the 'ON/OFF' button to turn on the meter.
- Immerse the electrode into the solution to be tested, ensuring the electrode is fully submerged.
- Gently stir the solution and wait for the reading to stabilize (usually a few seconds). The pH value and temperature will be displayed on the LCD screen.
6.2 HOLD Function
Press the 'HOLD' button during measurement to freeze the current reading on the display. Press 'HOLD' again to release the reading and resume live measurement.
6.3 Backlight
Press the light bulb icon button to toggle the backlight on or off for better visibility in low-light conditions.
6.4 Temperature Unit Switching
The meter displays temperature in Celsius (℃). Refer to the user manual for specific instructions on switching temperature units if available, or assume Celsius is the default and only unit.
7. Calibration
The PH818 features 2-point automatic calibration. For accurate measurements, regular calibration is essential. Please note that calibration powder is NOT included with this device. Users must purchase appropriate pH buffer powders (e.g., pH 6.86 and pH 4.00 or pH 9.18) separately to prepare calibration solutions.
7.1 Calibration Procedure
- Prepare the pH buffer solutions (e.g., pH 6.86 and pH 4.00) according to the instructions on the calibration powder packets. Use distilled water for preparation.
- Turn on the pH meter.
- Immerse the electrode into the first buffer solution (e.g., pH 6.86).
- Press and hold the 'CAL/A' button until the display shows 'CAL' or starts flashing the buffer value. The meter will automatically recognize the buffer solution and calibrate itself.
- Once the calibration is complete, the meter will return to measurement mode.
- Rinse the electrode with distilled water.
- Repeat steps 3-5 for the second buffer solution (e.g., pH 4.00).
- After successful 2-point calibration, the meter is ready for use.
Important: Always calibrate the meter with fresh buffer solutions. Old or contaminated buffer solutions can lead to inaccurate calibration.
8. Maintenance
8.1 Electrode Care
- Always rinse the electrode with distilled water before and after each use.
- Gently blot the electrode dry with a clean, soft tissue. Do not wipe or rub, as this can damage the sensitive glass bulb.
- For long-term storage, ensure the electrode is kept moist. It is recommended to store the electrode in a small amount of pH 7.0 buffer solution or electrode storage solution within its protective cap. Never store the electrode dry.
8.2 Cleaning
If the electrode becomes contaminated or dirty, soak it in a cleaning solution (e.g., a dilute acid solution for inorganic deposits or a dilute detergent solution for organic deposits) for a short period, then rinse thoroughly with distilled water and re-calibrate.
8.3 Probe Replacement
The pH sensor probe is replaceable. If the electrode performance degrades significantly and calibration no longer restores accuracy, it may be time to replace the probe. To replace, carefully unscrew the old probe and screw in a new, compatible replacement probe. Always re-calibrate the meter after replacing the probe.
9. Troubleshooting
- Inaccurate Readings:
- Ensure the meter is properly calibrated.
- Check if the electrode is clean and free from contamination.
- Verify that the electrode is fully submerged in the solution.
- Ensure the batteries have sufficient power.
- The electrode may be old or damaged and require replacement.
- No Display/Faint Display:
- Check battery installation and polarity.
- Replace batteries if they are low or depleted.
- Slow Response Time:
- The electrode may be dry or contaminated. Re-condition and clean the electrode.
- The electrode may be nearing the end of its lifespan and require replacement.
10. User Tips
- Always store the pH meter with the protective cap on and the electrode kept moist with storage solution or pH 7.0 buffer to prolong its lifespan.
- For best accuracy, allow the meter to reach the temperature of the solution being tested before taking a reading.
- When measuring, gently stir the solution to ensure homogeneity and stable readings.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the seller's policies or contact the point of purchase. Keep your purchase receipt as proof of purchase.