SUMRY MPS-V MAX 10.2kW

Contents

SUMRY MPS-V MAX Series 10.2kW 48VDC Hybrid Solar Inverter User Manual

Model: MPS-V MAX 10.2kW

1. Introduction

The SUMRY MPS-V MAX Series 10.2kW 48VDC Hybrid Solar Inverter is a high-efficiency pure sine wave inverter designed for both on-grid and off-grid solar power systems. It features dual PV input, dual MPPT solar charge controllers, and dual AC output, providing reliable and continuous power for various applications. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your inverter.

SUMRY MPS-V MAX Series 10.2kW Hybrid Solar Inverter with key specifications
Figure 1: SUMRY MPS-V MAX Series 10.2kW Hybrid Solar Inverter with key specifications including 140A Max AC Charging Current, 230VAC Grid Output Voltage, 90-450VDC MPPT Voltage Range, and 50Hz/60Hz Frequency Range.
Key features of the SUMRY Hybrid Solar Inverter
Figure 2: Key features include inverter running without battery, built-in 160A MPPT solar charger (for 10.2kW model), high PV input voltage range (90-500VDC), dual output, dual PV input, WiFi & GPRS availability for iOS and Android, and touch button interface.

2. Safety Information

Please read all instructions and warnings carefully before installation and operation. This inverter generates high voltage and current. Improper installation or use can result in serious injury or death. Only qualified personnel should perform installation and maintenance.

  • Ensure proper grounding.
  • Do not disassemble the inverter.
  • Keep away from flammable materials.
  • Ensure adequate ventilation.
  • Disconnect all power sources before servicing.

3. Setup and Installation

This section outlines the physical installation and wiring connections for the inverter. Refer to the diagrams for correct port identification and connection procedures.

3.1 Unboxing and Inspection

Carefully remove the inverter from its packaging. Inspect the unit for any physical damage. Ensure all components listed in the packing list are present.

Video 1: Unboxing and initial connection demonstration of the SUMRY Hybrid Solar Inverter.

3.2 Physical Dimensions and Port Overview

The inverter has dimensions of 537mm (Length) x 390mm (Width) x 130mm (Height).

Dimensions and rear panel layout of the SUMRY Hybrid Solar Inverter
Figure 3: Inverter dimensions and a detailed view of the rear panel showing AC In, Main Out, Second Out, PV In, Battery, and COMM ports.
Product Overview with labeled connection ports
Figure 4: Product Overview detailing the connection points: 1. AC input, 2. Main output, 3. Second output, 4. PV1 and PV2 input, 5. Battery input, 6. RS-232/RS-485/WIFI communication port.

3.3 Wiring Connections

Follow these steps for wiring the inverter:

  1. Battery Connection: Connect the battery cables to the inverter's battery terminals. Ensure correct polarity (positive to positive, negative to negative). The inverter supports various battery types including Flooded, Gel, Lithium-iron phosphate, Lithium-ion, and AGM/Sealed.
Battery connection diagram for the inverter
Figure 5: Diagram illustrating the connection of multiple 12V batteries to the inverter.
Compatible battery types for the inverter
Figure 6: The inverter is compatible with multiple battery types including Flooded, Gel, Lithium-iron phosphate, Lithium-ion, AGM/Sealed, and user-customized batteries.
  1. PV Input Connection: Connect your solar panels to the PV1 and PV2 input terminals. Ensure the PV array open circuit voltage and operating voltage are within the specified ranges.
  2. AC Input Connection: Connect the AC input from your utility grid or generator to the AC IN terminals.
  3. AC Output Connection: Connect your AC loads to the MAIN OUT and SECOND OUT terminals. The inverter features dual AC outputs.
  4. Communication Port: Connect the RS-232/RS-485/WIFI communication port for monitoring and control via the dedicated app.
Basic system architecture diagram for the hybrid solar inverter
Figure 7: Basic System Architecture showing connections for Solar Power, Batteries, Generator/Utility, and AC Loads (Household, Office, Industrial Equipment).

4. Operating Instructions

The inverter is designed for user-friendly operation with a clear LCD display and touch buttons.

4.1 Powering On/Off

Once all connections are secure, switch on the battery breaker (if applicable), then the AC input breaker, and finally the inverter's power switch. To power off, reverse the sequence.

4.2 LCD Display and Function Buttons

The LCD display provides real-time information about the inverter's status, input/output voltages, battery status, and more. Use the function buttons to navigate menus and adjust settings.

LCD Display, Function Buttons, and LED Indicators with descriptions
Figure 8: Detailed view of the LCD Display and Function Buttons. Includes a table for LED Indicator messages and Function Key descriptions.

LED Indicator Messages:

LED IndicatorColorMessages
INV/ACGreenSolid On: Output is powered by utility in Line mode.
Flashing: Output is powered by battery or PV in battery mode.
CHGGreenSolid On: Battery is fully charged.
Flashing: Battery is charging.
FAULTRedSolid On: Fault occurs in the inverter.
Flashing: Warning condition occurs in the inverter.

Function Keys:

Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

4.3 Remote Monitoring and Control

The inverter supports remote monitoring and control via a dedicated mobile application (available for iOS and Android) using WiFi or GPRS. This allows you to check system status, adjust settings, and receive alerts from anywhere.

Mobile app for monitoring and controlling the inverter
Figure 9: Monitor and control your inverter via the Smartess App, available on app stores.

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your SUMRY Hybrid Solar Inverter.

  • Cleaning: Keep the inverter's vents and surfaces clean and free from dust and debris to ensure proper heat dissipation.
  • Connection Checks: Periodically inspect all wiring connections for tightness and signs of corrosion.
  • Battery Health: Monitor battery voltage and health, especially for lead-acid batteries, to ensure they are functioning correctly.
  • Environmental Conditions: Ensure the inverter is operating within its specified temperature and humidity ranges.

6. Troubleshooting

This section provides guidance on common issues. Refer to the LED indicator messages for initial diagnosis.

6.1 Common Issues and Solutions

  • No Power Output: Check AC input, battery connections, and PV input. Ensure all breakers are on.
  • Fault LED On: Refer to the LED Indicator Messages table (Figure 8) for the specific fault code and consult the full manual for detailed troubleshooting steps.
  • Warning LED Flashing: Indicates a warning condition. Check system parameters via the LCD or app to identify the specific warning.

6.2 Protection Features

The inverter is equipped with comprehensive protection features to ensure safe operation:

Icons representing various protection features of the inverter
Figure 10: Comprehensive protections include Overload Protection, Overheating Protection, High/Low Voltage Protection, Battery Protection, Short Circuit Protection, Overcurrent Protection, Anti-Reverse Protection, and Power Failure Protection.

7. Specifications

AttributeValue
Model Numbervmax 10.2kw
Rated Power10.2kW
Output Power1 - 200 KW
Output TypeSINGLE
Output Frequency50/60hz
Input Voltage220/230/240VAC
Selectable Voltage Range170-280VAC (for personal computers), 90-280VAC (for home appliances)
Frequency Range50hz/60hz (auto sensing)
AC Voltage Regulation (Battery Mode)230VAC±5%
Wave FormPure Sine Wave
Battery Voltage48VDC
Maximum PV Array Open Circuit Voltage102VDC (Note: Images indicate 90-500VDC MPPT range)
MPPT Range @ Operating Voltage30-80VDC (Note: Images indicate 90-450VDC MPPT range)
Maximum AC Charging Current20 or 30A (Note: Images indicate 140A/160A for solar charging)
Standby Power Consumption2W
Size (D*W*H)550*350*150mm (Note: Images indicate 537*390*130mm)
Weight17kg
Is Smart DeviceNo (Note: WiFi/GPRS for app monitoring is available as an option)
CertificationCE, RoHS, WEEE

Note: Some specifications may vary slightly between different data sources (JSON vs. images). Please refer to the product label on your specific unit for the most accurate information.

8. User Tips

  • Parallel Operation: The inverter supports parallel operation, allowing you to connect multiple units to increase overall power capacity. Consult the detailed wiring diagrams in the comprehensive manual for proper parallel setup.
  • Appliance Compatibility: This inverter is capable of powering a wide range of appliances, including high-power devices like radial compressors (e.g., 2.5kW at 220V), provided the total load does not exceed the inverter's rated output.
  • Battery-less Operation: The inverter can operate without a battery, directly utilizing solar power or grid/generator input to supply loads.
Inverter powering various household and office equipment
Figure 11: The inverter can power various household, office, and RV equipment, ensuring power during outages.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the SUMRY Official Store or your authorized dealer. Keep your purchase receipt as proof of purchase for warranty claims.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.