1. Introduction
This manual provides comprehensive instructions for the safe and effective use of your KKMOON ZL126/ZL128 Series Digital Multimeter. Designed for electrical testing, automotive repair, and general household improvements, this device offers a range of measurement functions including voltage, current, resistance, capacitance, frequency, and temperature. Please read this manual thoroughly before operation to ensure proper use and to prevent potential hazards.
2. Safety Information
WARNING: Failure to follow these safety instructions may result in electric shock, fire, or personal injury.
- Always ensure the multimeter is in the correct measurement mode before connecting test leads to a circuit.
- Do not exceed the maximum input values specified for each function. Refer to the specifications section for details.
- Exercise extreme caution when working with live circuits. Always assume circuits are live until proven otherwise.
- Inspect test leads for damage (cuts, cracks, exposed metal) before each use. Replace immediately if damaged.
- Do not operate the multimeter if it appears damaged or is not functioning properly.
- Replace batteries promptly when the low battery indicator appears to ensure accurate readings and proper operation.
- NCV (Non-Contact Voltage) detection is a safety feature and should not be used as the sole method to determine the presence of voltage. Always verify with direct contact measurements when possible.
- Keep the device away from water, dust, and extreme temperatures.
3. Package Contents
Please check the package for the following items:
- 1 x Digital Multimeter (ZL126A, ZL126B, ZL128A, or ZL128B model)
- 2 x Universal Test Leads (Red and Black)
- 1 x Temperature Probe (Included with ZL128A/ZL128B models only)
- 1 x USB Charging Cable (Included with ZL126B/ZL128B models only)
- 1 x User Manual

4. Product Overview
The ZL126/ZL128 series multimeters feature a concise design with a large, clear display and intuitive controls.
4.1 Key Features
- Display: Large color display with backlight and large font for easy data reading.
- Buttons: LIVE, HOLD, H/L NCV, SEL for mode selection and special functions.
- Input Ports: Dedicated jacks for COM (common), VΩHz (voltage, resistance, frequency, capacitance, diode, continuity), and 10A (current measurement for ZL128A/B).
- LED Flashlight: Built-in LED for illuminating dark work areas.
- NCV Sensor: Non-contact voltage detection for enhanced safety.
- Fire Wire Recognition: Identifies live wires.
- Auto Power Off: Automatically shuts down after a period of inactivity to conserve battery.


5. Setup
5.1 Battery Installation (ZL126A/ZL128A)
- Locate the battery compartment on the back of the multimeter.
- Open the compartment cover.
- Insert 3 AAA batteries, observing correct polarity (+ and -).
- Close the battery compartment cover securely.
5.2 Charging (ZL126B/ZL128B)
The ZL126B and ZL128B models feature a built-in 1000mAh rechargeable battery.
- Connect the provided USB Type-C cable to the multimeter's charging port.
- Connect the other end of the USB cable to a suitable USB power source (e.g., computer, USB wall adapter).
- The battery indicator on the display will show the charging status. A full charge provides long operating time.

5.3 Connecting Test Leads
- Insert the black test lead into the "COM" (common) jack.
- For most measurements (voltage, resistance, capacitance, frequency, diode, continuity), insert the red test lead into the "VΩHz" jack.
- For current measurements (ZL128A/ZL128B models only), insert the red test lead into the "10A" jack.
6. Operating Modes and Functions
6.1 Power On/Off
Press the power button (typically a red button on the side or top) to turn the multimeter on or off. The device features automatic power-off to save battery life after a period of inactivity.
6.2 Automatic Mode
The multimeter defaults to auto-ranging mode, automatically detecting the measurement type (voltage, resistance, continuity) when test leads are connected to a circuit.
6.3 Manual Mode / Function Selection (SEL button)
Press the "SEL" button to cycle through different measurement functions within a mode (e.g., AC/DC voltage, diode/continuity).
6.4 Voltage Measurement (AC/DC)
- Connect test leads as described in Section 5.3.
- Select AC or DC voltage mode if not automatically detected.
- Apply probes to the circuit or component. The display will show the voltage and frequency (for AC voltage).

6.5 Current Measurement (AC/DC, ZL128A/ZL128B only)
WARNING: Ensure the red test lead is in the "10A" jack. Never measure current in parallel with a voltage source; always break the circuit and insert the multimeter in series.
- Break the circuit and insert the multimeter in series with the load.
- Select AC or DC current mode.
- The display will show the current in Amperes (A).

6.6 Resistance Measurement
- Ensure the circuit is de-energized before testing resistance.
- Connect test leads to the component.
- The display will show resistance in Ohms (Ω).
6.7 Capacitance Measurement
- Ensure the capacitor is fully discharged before testing.
- Connect test leads to the capacitor terminals.
- The display will show capacitance in Farads (F).
6.8 Diode Test
- Ensure the circuit is de-energized.
- Connect test leads to the diode.
- The display will show the forward voltage drop.
6.9 Continuity Test (On and Off Beep)
- Ensure the circuit is de-energized.
- Connect test leads across the component or wire.
- A continuous beep indicates continuity (low resistance).

6.10 Frequency Measurement
- Connect test leads to the signal source.
- The display will show frequency in Hertz (Hz).
6.11 Temperature Measurement (ZL128A/ZL128B only)
- Connect the temperature probe to the multimeter.
- Select temperature mode.
- Place the probe tip on or near the object to be measured.
- The display will show the temperature in Celsius (°C) or Fahrenheit (°F).

6.12 NCV (Non-Contact Voltage) Detection
- Hold the NCV sensor (located at the top of the multimeter) near a live wire or electrical outlet.
- The multimeter will indicate the presence of AC voltage with an audible alarm and visual indicators on the display.
- Use the "H/L NCV" button to toggle between high and low sensitivity modes.

6.13 Live Wire Function (LIVE button)
- Connect the red test lead to the appropriate jack.
- Press the "LIVE" button to activate the live wire detection mode.
- Touch the red probe to the wire. The multimeter will indicate if it's a live wire.

6.14 Data Hold (HOLD button)
Press the "HOLD" button to freeze the current reading on the display. Press it again to release the hold function and resume live readings.
6.15 Flashlight
Activate the built-in LED flashlight for illumination in dark environments by pressing the dedicated flashlight button (if available) or a combination of buttons as indicated on the device.

6.16 Line Break Point Detection
Utilize the NCV function to trace wires and detect breaks. The signal strength indicated by the multimeter will drop or disappear at the point of a wire break.

7. Specifications
The following table details the specifications for the ZL126/ZL128 series digital multimeters:
| Feature | ZL126A | ZL126B | ZL128A | ZL128B |
|---|---|---|---|---|
| Max Count | 6000 counts | 6000 counts | 9999 counts | 9999 counts |
| Power Supply | 3 * AAA batteries (not included) | Built-in 1000mAh battery (USB) | 3 * AAA batteries (not included) | Built-in 1000mAh battery (USB) |
| DC Voltage | 0.5V-600V (Auto), 0V-600V (Manual) | 0.5V-600V (Auto), 0V-600V (Manual) | 1V-1000V (Auto), 0V-1000V (Manual) | 1V-1000V (Auto), 0V-1000V (Manual) |
| AC Voltage | 1V-600V (Auto), 0V-600V (Manual) | 1V-600V (Auto), 0V-600V (Manual) | 1V-750V (Auto), 0V-750V (Manual) | 1V-750V (Auto), 0V-750V (Manual) |
| AC/DC Current | Not supported | Not supported | 0mA-10A | 0mA-10A |
| Resistance | 0-10MΩ | 0-10MΩ | 0-100MΩ | 0-100MΩ |
| Capacitance | 0-6mF | 0-6mF | 0-100mF | 0-100mF |
| Frequency | 10Hz-1KHz | 10Hz-1KHz | 0-10MHz | 0-10MHz |
| True RMS | 40-400Hz | 40-400Hz | 0-1KHz | 0-1KHz |
| Ambient Temperature | 0℃~60℃ | 0℃~60℃ | 0℃~60℃ | 0℃~60℃ |
| Probe Temperature | Not supported | Not supported | -50℃~1100℃ | -50℃~1100℃ |
| Data Retention | Yes | Yes | Yes | Yes |
| Firewire Detection | Yes | Yes | Yes | Yes |
| NCV Voltage Pen | Yes | Yes | Yes | Yes |
| NCV Analog Strip | Yes | Yes | Yes | Yes |
| Color Display | Yes | Yes | Yes | Yes |
| Function Indicator | Yes | Yes | Yes | Yes |
| Flashlight | Yes | Yes | Yes | Yes |
| Operation Mode | Auto Mode + Manual Mode | Auto Mode + Manual Mode | Auto Mode + Manual Mode | Auto Mode + Manual Mode |
| Package Dimensions | 150 x 50 x 20mm (5.91 x 1.97 x 0.79in) | 150 x 50 x 20mm (5.91 x 1.97 x 0.79in) | 150 x 50 x 20mm (5.91 x 1.97 x 0.79in) | 150 x 50 x 20mm (5.91 x 1.97 x 0.79in) |
| Package Weight | 280g (9.88oz) | 280g (9.88oz) | 280g (9.88oz) | 280g (9.88oz) |
8. Maintenance
8.1 Cleaning
To clean the multimeter, gently wipe the casing with a damp cloth and a mild detergent. Do not use abrasive cleaners, solvents, or immerse the device in water.
8.2 Storage
Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods (for ZL126A/ZL128A models), remove the AAA batteries to prevent leakage.
8.3 Calibration
The multimeter is factory calibrated. If you suspect inaccuracies or require recalibration, please contact customer support or a qualified service center.
8.4 Test Lead Care
Regularly inspect the test leads for any signs of damage, such as cuts, cracks, or damaged insulation. Replace damaged test leads immediately to ensure safety and accurate measurements.
9. Troubleshooting
If you encounter issues with your multimeter, refer to the following common problems and solutions:
- No Display/Power:
- Check the batteries (ZL126A/ZL128A) or charge level (ZL126B/ZL128B).
- Ensure batteries are inserted with correct polarity.
- Press the power button firmly.
- Inaccurate Readings:
- Ensure test leads are properly connected to the correct jacks.
- Verify that the correct measurement mode is selected for the task.
- Check for damaged test leads, which can cause intermittent or incorrect readings.
- Ensure the circuit is de-energized for resistance, capacitance, and diode tests.
- No NCV Detection:
- Ensure the NCV sensor is held directly over the live wire or source.
- Try toggling the H/L sensitivity button.
- Verify the battery level, as low battery can affect NCV performance.
- No Continuity Beep:
- Ensure the circuit is de-energized before performing a continuity test.
- Check for open circuits or components with high resistance, which will not trigger the beep.
10. Warranty and Support
This product comes with a 12-month manufacturer's limited warranty for defective items from the date of receipt. Accessories are covered by a 3-month warranty. The warranty does not cover items damaged or misused after receipt.
For warranty claims or technical support, please contact your retailer or the manufacturer directly. You will need to provide your order number and a detailed description of the defect or issue.