SMART SENSOR AS8800C

Contents

SMART SENSOR AS8800C Digital Combustible Gas Detector User Manual

Model: AS8800C

1. Introduction

The SMART SENSOR AS8800C is a professional digital combustible gas detector designed for accurate and reliable detection of flammable gases, such as Methane (CH4). This portable device features a high-precision semiconductor sensor, a flexible probe for reaching confined spaces, and provides both audible and visual alarms for gas leaks. It is an essential tool for ensuring safety in various environments where combustible gases may be present.

Front view of the SMART SENSOR AS8800C Combustible Gas Detector
Figure 1: Front view of the SMART SENSOR AS8800C Combustible Gas Detector

2. Safety Information

Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Do not operate the device if it appears damaged or is not functioning properly.
  • Ensure proper ventilation when testing for gas leaks.
  • Do not expose the device to extreme temperatures, humidity, or corrosive environments.
  • Keep the sensor probe clean and free from obstructions to ensure accurate readings.
  • Replace batteries promptly when the low battery indicator appears to maintain device functionality.
  • This device is intended for detecting combustible gases. It is not designed to detect toxic gases or oxygen deficiency.

3. Package Contents

Upon opening the package, please verify that all items listed below are present and in good condition:

  • 1 x Combustible Gas Detector (AS8800C)
  • 1 x Gift Box
  • 1 x Cloth Bag
  • 1 x User Manual
Contents of the AS8800C package including detector, manual, and carrying bag
Figure 2: AS8800C Combustible Gas Detector with its packaging and accessories.

4. Product Overview

Familiarize yourself with the components of your AS8800C gas detector:

Diagram of the AS8800C gas detector with labeled parts
Figure 3: Labeled components of the AS8800C Combustible Gas Detector.
  • LCD Display: Shows gas concentration (LEL/PPM) and temperature.
  • On/Off Button: Powers the device on or off.
  • Mode Button: Cycles through different operating modes or settings.
  • Backlight Adjustment Knob: Controls the brightness of the LCD backlight.
  • Low Alarm Indicator: LED indicator for low-level gas alarms.
  • High Alarm Indicator: LED indicator for high-level gas alarms.
  • Flexible Coil: The flexible part of the probe, allowing access to hard-to-reach areas.
  • Alarm Volume/Adjustment Knob: Adjusts the volume of the audible alarm.
  • Unit Selection: Button to switch between measurement units (e.g., LEL/PPM, °C/°F).
  • Sensor Probe: The tip containing the high-precision semiconductor sensor for gas detection.
  • Alarm Buzzer: Emits audible alarm sounds.

5. Specifications

FeatureSpecification
BrandSMART SENSOR
ModelAS8800C
MaterialABS Plastic
Detection GasCombustible Gas (e.g., CH4)
Measurement Range0-20% LEL / 0-10000 PPM
Resolution0.1% LEL / 1 PPM
Accuracy±5% LEL
Low Alarm Setting8% LEL (CH4)
High Alarm Setting15% LEL (CH4)
Temperature Range-10°C to 50°C (14°F to 122°F)
Response TimeT90 < 10 seconds
Recovery Time< 30 seconds
Measuring PrincipleSemiconductor
DisplayLarge LCD with Backlight
AlarmSound, Light
Power3 x 1.5V AA batteries (not included)
Operation Temperature-10°C to 50°C; <95% RH (Non-Gel)
CertificationsCE, FCC, RoHS
Close-up of the high-precision sensor and display, showing range, resolution, and accuracy
Figure 4: High-precision sensor details and display.
Diagram illustrating the extended flexible probe with measurements
Figure 5: Extended flexible probe for convenient measurement, extending up to 27.5cm.

6. Setup

6.1 Battery Installation

  1. Locate the battery compartment cover on the back of the device.
  2. Slide or unclip the cover to open the compartment.
  3. Insert three (3) 1.5V AA batteries, ensuring correct polarity (+/-).
  4. Close the battery compartment cover securely.
Image showing the battery compartment open with three AA batteries inserted
Figure 6: Battery compartment for 3x 1.5V AA batteries.

7. Operating Instructions

7.1 Power On/Off

  • To power on, press and hold the On/Off Button until the LCD display illuminates. The device will perform a self-test and warm-up.
  • To power off, press and hold the On/Off Button again until the display turns off.

7.2 Gas Detection

  1. After powering on and warm-up, the device is ready for detection.
  2. Direct the flexible sensor probe towards the area suspected of a gas leak.
  3. Observe the LCD display for gas concentration readings (in %LEL or PPM).
  4. If a combustible gas is detected above the set alarm thresholds, the device will trigger both sound and light alarms.
Image showing the detector in use near a gas stove, with icons for Sound alarm and Light alarm
Figure 7: Detector in use, indicating sound and light alarm functions.

7.3 Alarm Settings

The device supports setting high and low alarm values. Refer to the full manual for detailed instructions on how to adjust these settings using the Mode Button and Alarm Volume/Adjustment Knob.

7.4 Unit Conversion

The AS8800C allows for conversion of gas measurement units and temperature units:

  • Gas Unit Conversion: Press the Unit Selection Button to switch between %LEL and PPM for gas concentration readings.
  • Temperature Unit Conversion: Press the Unit Selection Button to switch between Celsius (°C) and Fahrenheit (°F) for temperature readings.
Diagram showing unit conversion options for Gas (LEL/PPM) and Temperature (°C/°F)
Figure 8: Gas and temperature unit conversion options.

7.5 Backlight Display

The device features an HD backlit LCD display for clear readings in various lighting conditions. Use the Backlight Adjustment Knob to control the backlight intensity.

Close-up of the HD backlit LCD display
Figure 9: HD backlit LCD display for clear visibility.

8. Maintenance

  • Cleaning: Wipe the device with a soft, damp cloth. Do not use abrasive cleaners or solvents. Keep the sensor probe clean and free of dust or debris.
  • Battery Replacement: Replace all three AA batteries when the low battery indicator appears on the display. Do not mix old and new batteries or different types of batteries.
  • Storage: When not in use for extended periods, remove the batteries and store the device in its cloth bag in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Sensor Care: The semiconductor sensor is sensitive. Avoid physical impact or exposure to harsh chemicals that could damage it.

9. Troubleshooting

ProblemPossible CauseSolution
Device does not power onDead or incorrectly installed batteriesReplace batteries with new ones, ensuring correct polarity.
Inaccurate or no gas readingSensor probe is dirty or obstructed; Device not warmed up; Sensor damage.Clean the sensor probe. Allow adequate warm-up time. If problem persists, contact support.
Alarm sounds continuously or falselyHigh background gas level; Alarm sensitivity too high; Sensor malfunction.Move to a fresh air environment. Adjust alarm settings if necessary. If problem persists, contact support.
LCD display is dim or unreadableLow battery; Backlight setting too low.Replace batteries. Adjust the backlight adjustment knob.

10. User Tips

No specific user tips were available from reviews or Q&A for this product. However, general tips for gas detectors include:

  • Always test the device in a known clean air environment before use to ensure proper calibration and function.
  • When searching for a leak, move the probe slowly to allow the sensor sufficient time to react to changes in gas concentration.
  • Be aware of potential false positives from non-combustible vapors (e.g., alcohol-based cleaners) that might temporarily trigger the sensor.
Collage of application scenarios for the gas detector
Figure 10: Various applications for the combustible gas detector, including industrial and domestic settings.

11. Warranty and Support

11.1 Limited Warranty

This SMART SENSOR AS8800C Combustible Gas Detector comes with a 24-month manufacturer's limited warranty for defective items, starting from the date of receipt. Accessories are covered by a 3-month warranty. This warranty does not cover items damaged due to misuse or improper handling after receipt.

11.2 Warranty Claims

To make a warranty claim, defective items MUST be reported and returned within the warranty period, preferably in their original packaging. You must provide details of the defect and your order number. Items with an expired warranty will not be repaired or replaced under warranty.

11.3 Customer Support

For technical assistance, troubleshooting, or warranty inquiries, please contact your retailer or the manufacturer's customer service. Refer to the product packaging or the seller's website for contact information.

© 2023 SMART SENSOR. All rights reserved.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.