1. Introduction
The MASTECH MS6818 is a professional, portable wire and cable tester designed for locating and tracing wires and cables in various environments. It can detect breaks, shorts, and fuses in cables, including those in walls, underground, or within conduits. This device is suitable for both charged and uncharged conductors, offering high precision for a wide range of applications.
2. Safety Information
Always observe the following safety precautions when using the MS6818 to prevent personal injury or damage to the device:
- Do not use the device if it appears damaged or if the insulation on test leads is compromised.
- Ensure the device is used within its specified voltage and current ratings.
- Always disconnect power to the circuit before connecting or disconnecting test leads, especially when working with charged conductors.
- Wear appropriate personal protective equipment (PPE), such as insulated gloves and safety glasses.
- Do not operate the device in wet conditions or in explosive atmospheres.
- Refer to the full safety guidelines in the included Quick Start Guide/Manual.
3. Package Contents
Verify that all items are present in your package:
- MS6818 Transmitter
- MS6818 Receiver
- Test Leads (2x)
- Test Probes (2x)
- Alligator Clips (2x)
- Grounding Rod
- Carry Bag
- User's Manual (this document)

4. Product Overview
The MS6818 consists of two main units: a Transmitter and a Receiver. Both units feature an LCD backlit display for clear readings and various buttons for operation.
4.1. Functional Description

- Locate Breakpoint of the cable: Pinpoint where a cable is broken.
- Locate the Short Circuit Point of cable: Identify the exact location of a short circuit.
- AC/DC Voltage Test: Measure AC/DC voltage up to 400V.
- NCV Test: Non-Contact Voltage detection.
- Auto Power-off: Conserves battery life.
- Auto/Manual Mode: Allows selection between automatic and manual operation.
- Flashlight: Integrated for working in low-light conditions.
- Backlight: For improved visibility of the display.
- Sensitivity Adjuster: Allows fine-tuning the receiver's sensitivity.
- Buzzer: Provides audible feedback during detection.
4.2. Controls and Display

The Transmitter features a liquid crystal display, mute function, electric hand torch, power switch, upward/downward selection buttons, and start/stop button. The Receiver includes a probe, electric hand torch, liquid crystal display with backlight, power switch, adjustment buttons, and a manual button.
5. Specifications
| Parameter | Value |
|---|---|
| Transmitter Specifications | |
| Output Signal | 125kHz |
| External Voltage | DC12~400V AC12~400V (50~60Hz) ±2.5% |
| Fuse | F0.5A 1000V |
| MIN Current | about 31mA |
| MAX Current | about 115mA |
| Working Temperature | 0~40℃, with MAX relative humidity of 80% |
| Storage Temperature | -20~60℃, with MAX relative humidity of 80% |
| Altitude | <2000m> |
| Product Size | 190mm x 89mm x 42.5mm / 7.48" x 3.5" x 1.67" |
| Product Weight | 420g / 0.92lb |
| Power Supply | 1x9V 6F22 Battery (Not Included) |
| Receiver Specifications | |
| Depth of Tracking | Depends on Material and Specific Applications |
| Cable Locating (Single pole) | about 0~2m |
| Cable Locating (Dual pole) | about 0~0.5m |
| Mode (Single loop line) | Up to 2.5m |
| MIN Current | about 32mA |
| MAX Current | about 89mA |
| Working Temperature | 0~40℃, with MAX relative humidity of 80% |
| Storage Temperature | -20~60℃, with MAX relative humidity of 80% |
| Altitude | <2000m> |
| Product Size | 241.5mm x 78mm x 38.5mm / 9.5" x 3" x 1.5" |
| Product Weight | 350g / 0.77lb |
| Power Supply | 6x1.5V AAA Battery (Not Included) |
| Certificate | CE / ETL / RoHS |
| Safety Rating | CAT III 300V |
6. Setup
6.1. Battery Installation
The Transmitter requires one 9V 6F22 battery, and the Receiver requires six 1.5V AAA batteries. Batteries are NOT included with the product.
- Locate the battery compartment on the back of both the Transmitter and Receiver.
- Use a screwdriver to open the battery compartment cover.
- Insert the batteries, ensuring correct polarity (+/-).
- Close the battery compartment cover and secure it with the screw.

6.2. Connecting Test Leads
Before connecting, ensure the circuit is de-energized if working with uncharged conductors. For charged conductors, exercise extreme caution and follow all safety protocols.
- Connect the red test lead to the positive (+) terminal and the black test lead to the negative (-) terminal on the Transmitter.
- Attach the test probes or alligator clips to the test leads as needed for your application.
- Connect the test leads to the circuit or cable you wish to trace or test.
7. Operating Instructions
7.1. Power On/Off
Press the 'POWER' button on both the Transmitter and Receiver to turn them on or off. The devices feature an auto power-off function to conserve battery life.
7.2. Tracing Wires and Cables
The MS6818 can trace both charged and uncharged conductors. The depth of tracking depends on the material and specific application.
- For Uncharged Conductors: Connect the Transmitter to the cable. Use the Receiver to follow the signal emitted by the Transmitter along the cable path.
- For Charged Conductors: Connect the Transmitter to the live circuit. The Receiver will detect the signal.


7.3. Finding Breaks and Shorts
To locate breaks or short circuits in in-wall or underground wiring:
- Connect the Transmitter to one end of the cable.
- Use the Receiver to scan along the cable path. A change or loss of signal indicates a break or short.

7.4. Locating Metal Pipes and Conduits
The MS6818 can also be used to find plumbing and floor heating pipes.

7.5. AC/DC Voltage Measurement
The Transmitter can measure 12-400V AC/DC voltage. Connect the test leads to the voltage source, and the reading will be displayed on the Transmitter's screen.

7.6. UAC Function
The UAC function allows for detection of live wires without direct contact. Hold the Receiver near the wire, and it will indicate the presence of AC voltage.
7.7. Sensitivity Adjustment
The Receiver's sensitivity can be adjusted using the 'LEVEL SEL.' buttons to optimize detection for different depths and materials.
7.8. Backlight and Flashlight
The Receiver and Transmitter are equipped with a backlight for the display and a flashlight for illuminating the work area. Activate these features using the dedicated buttons.
8. Maintenance
8.1. Battery Replacement
When the battery indicator shows low power, replace the batteries promptly to ensure accurate readings and proper operation. Refer to Section 6.1 for battery installation instructions.
8.2. Cleaning
Clean the device and accessories with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the device is dry before storage or use.
8.3. Storage
Store the MS6818 in its carry bag in a cool, dry place away from direct sunlight and extreme temperatures. Remove batteries if the device will not be used for an extended period.
9. Troubleshooting
- No Power: Check battery installation and ensure batteries are not depleted.
- Weak Signal/Inaccurate Readings: Adjust the receiver's sensitivity. Ensure proper connection of the transmitter. Check for strong electromagnetic interference in the area.
- No Detection: Verify that both the transmitter and receiver are powered on and functioning. Ensure the transmitter is correctly connected to the circuit/cable.
10. User Tips
- Battery Awareness: Remember that the MASTECH MS6818 does not come with batteries. Purchase one 9V 6F22 battery for the Transmitter and six 1.5V AAA batteries for the Receiver before first use.
- Signal Strength: For optimal tracing, especially in complex environments, experiment with different sensitivity levels on the receiver.
- Environmental Factors: The depth and accuracy of tracking can be affected by the surrounding materials (e.g., concrete, soil) and the presence of other electrical fields.
11. Warranty and Support
This product comes with a standard manufacturer's warranty. For warranty claims, technical support, or service inquiries, please contact the seller or authorized service center. Keep your purchase receipt as proof of purchase.