1. Introduction
Thank you for choosing the VEVOR 1800W High Pressure PCP Air Compressor Pump. This manual provides essential information for the safe and efficient operation, setup, and maintenance of your compressor. Please read this manual thoroughly before use and retain it for future reference.

Figure 1: VEVOR 1800W High Pressure PCP Air Compressor Pump
Video 1: Product Overview of the VEVOR High Pressure Compressor
2. Safety Instructions
WARNING: Failure to follow these safety instructions may result in serious injury, property damage, or explosion.
Oil Plug Replacement:

Figure 2: Critical Safety Warning for Oil Plug Replacement
Before starting the machine, you MUST replace the oil plug with the breathing valve. Failure to do so will cause the device to explode due to internal pressure buildup.
Lubrication:
Ensure the lubricant oil (ISO VG46/AW46, 0.4L, purchased separately) has been added to the pump before starting. Running the pump without proper lubrication will cause permanent damage.
Water Cooling System:
The compressor uses a water-cooling system. Ensure the water tank (purchased separately) is filled and the water pump is connected and functioning before operation. The ideal working temperature range is 50℃~70℃. The maximum safe temperature is 75℃. If the temperature reaches 75℃, immediately replace the cooling water or stop the machine to prevent overheating and damage.
Manual Stop Operation:
This is a manual stop compressor. You must manually turn off the machine once the required pressure is reached. Do not rely on automatic shutdown for pressure. Continuously monitoring the pressure gauge is essential.

Figure 3: Manual Stop Operation and Pressure Gauge
Operating Distance:
Do not stand near the compressor when it is running. There is a potential danger of pipe burst or connecting fitting blow-off under high pressure.
Ventilation:
Operate the compressor in a well-ventilated area to prevent heat buildup.
Electrical Safety:
Ensure the power supply matches the compressor's voltage (220V/50Hz). Do not operate with damaged cords or plugs. Keep away from water.
Children and Pets:
Keep children and pets away from the operating compressor.
3. Product Features
- High Pressure Performance: Equipped with an 1800W copper motor, capable of reaching 4500PSI/300BAR/30MPA. Inflation rate of 2800R/min and air flow of 40-50L/min.
- Efficient Cooling System: Features both air and water cooling for fast heat dissipation. Includes an LED temperature monitor for real-time temperature tracking.
- Enhanced Safety: Designed with an explosion-proof valve and durable metal protective covers for collision avoidance and security.
- Clean Air Output: Integrated water/oil separator filtration system ensures clean, dry air for your applications.
- Durable Construction: Stainless steel cylinder and cast aluminum cover provide long-lasting performance.
- Portable Design: Features a convenient hand grip for easy transport.

Figure 4: Premium Details: LED Temperature Monitor and Stainless Steel Cylinder Head

Figure 5: Water & Oil Separator for Impurity Filtering
4. Specifications

Figure 6: Product Specifications Overview
| Specification | Value |
|---|---|
| Model | GYDQBST1.8KWOC |
| Motor Power | 1800W |
| Shut Down | Manual Stop |
| Max. Pressure | 4500PSI / 300BAR / 30MPA |
| Voltage | 220V/50Hz |
| Motor Material | Copper |
| Cooling Way | Water-Cooling |
| Filtration | Water/Oil Separator |
| Lubricating Oil | ISO VG46/AW46 (Not included) |
| Inflating Rate | 2800R/min |
| Filling Time | 1gal/36min (1L/8min) |
| Tank Capacity | 0.66-1.50gal / 3-6.8L |
| Pressure Indicate | Gauge |
| Dimension | 14.5 x 7 x 15.7 inches (37 x 18 x 40 cm) |
| Net Weight | 40lb (18kg) |
| Max. Noise | 78dB |
| Compression Level | Two Stage |
| Cylinder Material | Stainless Steel |
| Cover Material | Cast Aluminum |
| Air Flow | 8.8-11GPM (40-50L/min); 1.5-1.8cfm |
| Air Hose Connection | 0.3in / 8mm Quick Connect Fitting |
5. Package Contents

Figure 7: Included Components in the Package
Upon unpacking, please verify that all items listed below are present and undamaged:
- 1 x VEVOR 1800W High Pressure Air Compressor
- 1 x Water Pump
- 1 x Water Pipe
- 1 x Breath Plug
- 2 x Pressure Relief Screw
- 1 x Spare Parts Kit (includes various seals and small components)
Note: Lubricating oil (ISO VG46/AW46) and a water tank for the cooling system are NOT included and must be purchased separately.
6. Setup Instructions
Unpacking: Carefully remove all components from the packaging. Inspect for any shipping damage.
Breathing Valve Installation: Locate the oil plug (usually a solid cap) and replace it with the provided breathing valve. This is a critical safety step to prevent explosion during operation. Refer to Figure 2 for visual guidance.
Lubrication: Fill the compressor with approximately 0.4L of ISO VG46/AW46 lubricating oil. Check the oil level indicator to ensure it is within the 'OK' range. Refill immediately if low.
Water Cooling System Setup:
- Place the water pump into a suitable water container (e.g., a bucket or tank, not included) filled with clean water.
- Connect the water pipe from the compressor to the water pump.
- Ensure the water pump is fully submerged and securely connected.

Figure 8: Water Cooling System Connection
Air Hose Connection: Connect the 0.3in/8mm quick connect fitting of the air hose to your target air tank (e.g., paintball tank, PCP air rifle). Ensure a secure, leak-free connection.
Power Connection: Connect the compressor to a grounded 220V/50Hz power outlet.
7. Operating Instructions
Pre-Operation Check:
- Confirm the breathing valve is installed.
- Verify oil level is correct.
- Ensure water cooling system is properly set up and functioning.
- Check all connections for tightness.
- Ensure the compressor is on a stable, level surface in a well-ventilated area.
Start the Water Pump: Turn on the water pump to begin circulating cooling water. Ensure water is flowing through the compressor's cooling lines.
Start the Compressor: Flip the power switch on the compressor to the 'ON' position. The compressor will begin to operate.
Monitor Pressure and Temperature:
- Continuously monitor the pressure gauge (Figure 3) and the LED temperature display (Figure 4).
- Maintain the operating temperature between 50℃ and 70℃. If it approaches 75℃, stop the compressor and change the cooling water immediately.
- Do not exceed the maximum pressure of 4500PSI/300BAR/30MPA for your target tank.
Manual Stop: Once the desired pressure is reached in your air tank, immediately turn off the compressor using the power switch. This is a manual stop unit; it will not shut off automatically.
Release Pressure: After stopping the compressor, slowly open the pressure relief screw(s) to release any residual pressure in the compressor's system before disconnecting the air hose. Use the provided pressure relief screws.
Disconnect: Once pressure is fully released, disconnect the air hose from your tank and then unplug the compressor from the power outlet.
8. Maintenance
Cooling Water Replacement: Change the cooling water every 20-30 minutes of continuous operation to prevent cylinder overheating. Use clean, fresh water.
Oil Level Check: Check the lubricating oil level daily before use. Refill with ISO VG46/AW46 oil if the level is low.
Oil Change: Regularly change the compressor oil according to usage frequency or manufacturer recommendations (typically every 50-100 hours of operation). Consult the full product manual if available for specific intervals.
Filter Maintenance: The water/oil separator filters impurities. Periodically inspect and clean or replace the filter elements as needed to ensure optimal air quality.
General Cleaning: Keep the exterior of the compressor clean and free from dust and debris. Ensure cooling vents are unobstructed.
Storage: When not in use, store the compressor in a dry, clean environment, away from direct sunlight and extreme temperatures.
9. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Compressor does not start | No power; Power switch off; Overload protection triggered | Check power connection; Turn on switch; Reset circuit breaker if tripped |
| Low pressure output | Air leaks; Clogged filter; Insufficient oil | Check all connections for leaks; Clean/replace filter; Check/add oil |
| Overheating | Insufficient cooling water; Clogged cooling lines; Poor ventilation | Change cooling water; Check water pump/lines; Ensure adequate airflow around compressor |
| Excessive noise/vibration | Loose components; Unit not on level surface; Internal issue | Check for loose parts and tighten; Place on stable surface; Contact support if persists |
| Oil/water in air output | Water/oil separator clogged or faulty | Inspect and clean/replace water/oil separator filter elements |
10. User Tips
- Always perform a quick visual inspection before each use to ensure no visible damage or loose connections.
- Keep a spare set of O-rings and seals from the spare parts kit on hand, as these are common wear items in high-pressure systems.
- Consider using distilled water for the cooling system to minimize mineral buildup over time.
- When filling smaller tanks, monitor the pressure very closely as they fill quickly.
- For optimal performance and longevity, avoid running the compressor continuously for extended periods without allowing it to cool down.
11. Warranty & Support
VEVOR products are designed for durability and performance. For any warranty claims, technical support, or spare parts inquiries, please contact your original point of purchase or the VEVOR customer service team. Please have your model number (GYDQBST1.8KWOC) and purchase date ready when contacting support.