SUMRY HGS Series Off Grid Solar Inverter User Manual

Models: HGS 3500W/24V, HGS 5500W/48V

1. Product Overview

The SUMRY HGS Series Off Grid Solar Inverter is a versatile power solution designed for various household appliances. It features a pure sine wave output, high conversion efficiency, and the ability to operate with or without batteries on sunny days. This manual provides essential information for the safe and efficient use of your inverter.

SUMRY HGS Off Grid Solar Inverter with key features

Figure 1: SUMRY HGS Off Grid Solar Inverter highlighting key features like 3500W/24V, 5500W/48V, 110A Max. Charging Current, 5KW/6KW Max. PV Array Power, 120-500VDC MPPT Range, and 50Hz/60Hz Frequency Range.

Key features of the HGS Solar Inverter

Figure 2: Diagram illustrating key features including No Need Battery, Wide PV Voltage (120-500VCD), MPPT 100A Charging Current, Remote LCD Display (Optional), Parallel Model (Optional), and WIFI connectivity.

Product Components

Product Overview diagram with labeled ports and indicators

Figure 3: Product Overview showing the front and rear panels. Key components include: 1. LCD display, 2. Status indicator, 3. Charging indicator, 4. Fault indicator, 5. Function buttons, 6. Power on/off switch, 7. AC input, 8. AC output, 9. PV input, 10. Battery input, 11. Circuit breaker, 12. RS485/RS232 communication port.

2. Setup and Installation

Mounting the Unit

Consider the following points before selecting where to install the inverter:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install the inverter at eye level in order to allow the LCD display to be read at all times.
  • For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and 50 cm above and below the unit.
  • The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall vertically.
  • Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
Mounting the inverter unit with clearance dimensions

Figure 4: Mounting diagram showing recommended clearances (20cm side, 50cm top/bottom) for proper ventilation. SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

System Connection

The HGS series inverter supports various connection configurations for solar modules, utility grid, generator, battery packs, and home appliances.

Solar System Connection Diagram for Off Grid Inverter

Figure 5: Off-Grid Solar System Connection Diagram. This diagram illustrates how solar modules, a generator, utility grid, battery packs, and home appliances connect to the inverter via air switches.

Battery Connection

Follow these steps to implement battery connection:

  1. Assemble battery ring terminal based on recommended battery cable and terminal size.
  2. Connect all battery packs as units requires.

NOTE: Please only use sealed lead acid battery or sealed GEL/AGM lead-acid battery. The inverter is also compatible with Lithium (LiFePO4) batteries.

Recommended battery cable and terminal sizes

Figure 6: Table showing Recommended Battery Cable and Terminal Size for 3.5KW 24V and 5.5KW 48V models, including typical amperage, battery capacity, wire size, ring terminal dimensions (D and L in mm), and torque value (Nm).

Video 1: A demonstration of connecting the SUMRY HGS solar inverter to power sources and loads, including AC input, AC output, PV input, and battery connections. It also shows the inverter powering a kettle, charging mobile phones, and running a fan.

3. Operation

LCD Display and Indicators

The inverter features an intuitive LCD display and LED indicators to provide real-time status and operational information.

LCD Function Description with numbered labels

Figure 7: LCD Function Description. This diagram labels various parts of the LCD screen and their meanings, including PV input, AC input, input voltage/frequency, setting programs, output voltage/frequency/load, load level, DC/AC inverter circuit status, battery level, utility charger circuit status, PV panel connection status, mains connection status, load supplied by utility power, unit alarm status, and overload indicator.

LED Indicator and Function Keys table

Figure 8: Table detailing LED Indicators and Function Keys. LED indicators (AC/INV, CHG, FAULT) show solid/flashing states and their corresponding messages (Output powered by utility/battery/PV, Battery fully charged/charging, Fault/Warning condition). Function keys (ESC, UP, DOWN, ENTER) describe their actions for navigating settings.

Wi-Fi Monitoring (Optional)

For enhanced monitoring and control, the inverter offers an optional Wi-Fi monitoring function. Download the SmartESS app for iOS or Android using the QR codes provided.

Wi-Fi Monitoring feature with SmartESS app QR codes

Figure 9: Wi-Fi Monitoring feature showing the inverter unit with a Wi-Fi module and QR codes for downloading the SmartESS app on iOS and Android devices.

4. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter. While specific maintenance schedules are not provided, general best practices include:

  • Keep the inverter clean and free from dust and debris.
  • Ensure proper ventilation by maintaining recommended clearances around the unit.
  • Periodically check all electrical connections for tightness and signs of corrosion.
  • Inspect the unit for any visible damage or unusual noises.

5. Troubleshooting

This section provides general guidance for common issues. For detailed troubleshooting, refer to the fault indicator messages on the LCD display (Figure 7 and 8).

  • No Power Output: Check input breaker, battery connections, and PV input. Ensure the power switch is ON.
  • Overload Warning: Reduce the connected load. Ensure the total wattage of appliances does not exceed the inverter's rated power.
  • Battery Not Charging: Verify PV panel connections and output. Check utility grid connection if applicable.
  • Unusual Noises/Smells: Immediately power off the inverter and consult technical support.

6. Specifications

The SUMRY HGS series offers two main models with varying power outputs and battery voltages. Both models feature pure sine wave output and high efficiency.

Product parameters table for HGS 3500W and HGS 5500W

Figure 10: Product Parameters Table comparing HGS 3500W and HGS 5500W models. Includes Rated power, MAX.PV Array Power, Surge Power, MAX.Charging Current, Battery Voltage, MPPT Range@Operating Voltage, MAX. Efficiency, Dimension (D*W*H in mm), and Net Weight (kgs).

General Specifications

AttributeValue
Model NumberHGS
Output Power1 - 200 KW
Size50*32*14CM
Output TypeSINGLE
Weight10.5/11KG
Brand NameSUMRY
Output Frequency50Hz/60hz
Is Smart DeviceNo,Yes (depending on model)
OriginMainland China
CertificationCE
Voltage230vac
Work with or without batteryyes
Rated power3500w 3500VA/5500w 5500VA
Input voltage220/230/240VAC
Frequency range50/60hz AUTO sensing
Battery voltage3500w 24VDC/ 5500W 48VDC
Maximum charge current80A (Note: Image states 110A MPPT SCC)
MPPT RANGE @operating voltage120-500VDC

7. User Tips

  • Power Rating: Always ensure the inverter's power rating is higher than the appliance you intend to power. For multiple appliances, refer to the total wattage. A general recommendation is to choose a model at least 10% to 20% more than the maximum load.
  • Inductive Loads: For running inductive loads (e.g., motors, refrigerators) for extended periods, a pure sine wave inverter like the HGS series is recommended for stability and efficiency.
  • Battery-Free Operation: The HGS inverter can operate without batteries on sunny days, directly supplying power from solar panels to your loads.
  • Battery Compatibility: This inverter is compatible with various battery types, including sealed lead-acid, GEL/AGM lead-acid, and Lithium (LiFePO4) batteries.
  • Wi-Fi Monitoring: Utilize the optional Wi-Fi monitoring function with the SmartESS app for convenient remote monitoring of your system's performance.

8. Warranty and Support

Your SUMRY HGS Off Grid Solar Inverter comes with a 1-year warranty from the date of purchase. For any technical assistance, questions, or issues during pre-sale or after-sale, a professional engineer team is available to provide support.

© 2023 SUMRY Official Store. All rights reserved.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.