SUMRY MPS VIII ECO

Contents

SUMRY MPS VIII ECO Series On/Off Grid Solar Inverter

User Instruction Manual

Introduction

The SUMRY MPS VIII ECO Series is a versatile pure sine wave solar hybrid inverter designed for both on-grid and off-grid applications. It integrates a powerful MPPT solar charge controller, a high-efficiency inverter, and a configurable AC/Solar charger. This manual provides essential information for the safe and efficient operation of your inverter.

Product Overview

SUMRY MPS VIII ECO Series Solar Inverter

Figure 1: SUMRY MPS VIII ECO Series Solar Inverter

Video 1: Unboxing and Basic Wiring Demonstration

The MPS VIII ECO series offers models with power outputs of 3.6KW, 4.2KW, and 6.2KW, supporting 24V or 48V DC input and 110V or 220V AC output. It features a built-in 80A MPPT solar charger with a maximum PV input voltage range of 60-450VDC.

1. Setup and Installation

1.1 Unboxing and Inspection

Carefully unpack the inverter and inspect it for any damage. Ensure all components listed in the packing list are present.

1.2 Physical Dimensions

Inverter dimensions and components

Figure 2: Inverter Dimensions (D*W*H 420*310*110mm) and Component Overview

The inverter dimensions are approximately 420mm (Depth) x 310mm (Width) x 110mm (Height).

1.3 Connection Ports

The inverter features multiple connection ports on its rear panel:

  • AC In: For connecting to the utility grid or a generator.
  • Main Out: Primary AC output for loads.
  • Second Out: Secondary AC output for loads.
  • PV In: For connecting solar panels (PV1+, PV1-, PV2+, PV2-).
  • Battery: For connecting to the battery bank (+ and - terminals).
  • COMM: Communication port (RS232, RS485, WIFI/GPRS optional).
Labeled connection ports on the inverter

Figure 3: Rear Panel with Labeled Connection Ports

1.4 Wiring Instructions

Refer to the video demonstration and the following diagrams for proper wiring:

  1. Solar Panel Connection: Connect your solar panels to the PV IN terminals (PV1+, PV1-, PV2+, PV2-). Ensure correct polarity.
  2. Battery Connection: Connect your battery bank to the BATTERY terminals (+ and -). The inverter supports various battery types including lithium (LiFePo4, Li-ion) and lead-acid (Flooded, Gel, AGM/Sealed).
  3. AC Input/Output: Connect the utility grid or generator to AC IN. Connect your AC loads to MAIN OUT and SECOND OUT.
  4. Communication: Utilize the dual communication ports (BMS RS485 and WIFI RS232) for battery communication and remote monitoring.
Battery connection diagram for multiple 12V batteries

Figure 4: Example Battery Connection Diagram (for 6.2KW and 4.2KW models)

Basic System Architecture for On/Off Grid Solar Inverter

Figure 5: Basic System Architecture Diagram

2. Operating Instructions

2.1 LCD Display and Function Buttons

The inverter features an LCD display and function buttons for configuration and monitoring. The display shows real-time status, input/output parameters, and allows access to settings.

LCD Display, Function Buttons, and LED Indicators

Figure 6: LCD Display, Function Buttons, and LED Indicators

Function Keys:

  • ESC: To exit setting mode.
  • UP: To go to previous selection.
  • DOWN: To go to next selection.
  • ENTER: To confirm the selection in setting mode or enter setting mode.

2.2 LED Indicators

The LED indicators provide quick status updates:

LED IndicatorStatusMessages
INV/ACSolid OnOutput is powered by utility in Line mode.
Green FlashingOutput is powered by battery or PV in battery mode.
CHGGreen Solid OnBattery is fully charged.
FlashingBattery is charging.
FAULTRed Solid OnFault occurs in the inverter.
FlashingWarning condition occurs in the inverter.

2.3 Configurable Settings

The inverter allows configuration of various parameters via the LCD display:

  • Input Voltage Range: Configurable for home appliances or personal computers.
  • Battery Charging Current: Adjustable based on application needs.
  • AC/Solar Charger Priority: Set the charging source priority (e.g., Solar first, then AC).

2.4 Working Modes

The inverter supports different working modes to optimize power usage:

  • Only Solar: Power is supplied solely from solar panels.
  • Utility Priority: Utility grid is the primary power source, with solar/battery as backup.
  • Solar & Utility: A hybrid approach, balancing solar and utility power.
Diagram showing Only Solar, Utility Priority, and Solar & Utility working modes

Figure 7: Inverter Working Modes

2.5 Remote Monitoring

The inverter supports WIFI/GPRS (optional) for remote monitoring and control via a smart app. This allows real-time tracking of system performance.

Smart app monitoring interface for solar inverter

Figure 8: Monitor and Control via Smart App

3. Maintenance

To ensure optimal performance and longevity of your SUMRY MPS VIII ECO inverter, regular maintenance is recommended:

  • Cleanliness: Keep the inverter's vents and surfaces clean and free from dust and debris to prevent overheating.
  • Connections: Periodically check all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion.
  • Environment: Ensure the inverter is installed in a well-ventilated area, away from direct sunlight, moisture, and flammable materials.
  • Battery Health: Monitor your battery bank's health according to the battery manufacturer's guidelines.

4. Troubleshooting

The inverter is equipped with comprehensive protection features to safeguard itself and connected devices:

  • Overload Protection: Shuts down output if connected loads exceed capacity.
  • Over Temperature Protection: Protects against overheating.
  • Short Circuit Protection: Prevents damage from short circuits.
  • High/Low Voltage Protection: Safeguards against abnormal voltage levels.
  • Overcurrent Protection: Protects against excessive current draw.
  • Anti-Reverse Protection: Prevents damage from incorrect polarity connections.
  • Power Failure Protection: Ensures stable operation during power fluctuations.
Icons representing various protection features

Figure 9: Comprehensive Protection Features

If the inverter displays a fault or warning, refer to the LED indicator table (Figure 6) and consult the full user manual for specific error codes and troubleshooting steps.

5. Specifications

Key specifications for the SUMRY MPS VIII ECO Series Inverter:

FeatureSpecification
Brand NameSUMRY
Model NumberMPS VIII ECO
Output Power1 - 200 KW (Specific models: 3.6KW, 4.2KW, 6.2KW)
Output Current20A (Max AC Charging Current: 120A)
Output TypeSINGLE
Output Frequency50/60HZ auto sensing
AC Output Voltage110/220V-50Hz/60Hz (230VAC nominal)
WaveformPure Sine Wave
Battery Voltage24VDC/48VDC
Max Charge Current for Battery60A
Max Charge Current for Solar80A
Control TypeMPPT
Support Battery TypeLithium battery, LiFePo4; Lead acid battery (Flooded, Gel, Lithium-iron phosphate, Lithium-ion, AGM/Sealed, User custom)
Communication InterfaceRS232 (WIFI/GPRS optional)
Size (D*W*H)48*30*18CM (Product: 420*310*110mm)
Weight10/16KG (Net: 8.0-8.9kg, Gross: 9.0-10.0kg)
Operating Temperature-10°C to 50°C
Humidity5% to 95% Relative Humidity (Non-condensing)
CertificationCE
Detailed Product Data Sheet for MPS VIII ECO Inverter

Figure 10: Product Data Sheet

Diagram showing compatibility with various battery types

Figure 11: Compatible Battery Types

6. Warranty and Support

All SUMRY products come with a 1-year warranty from the store. For technical support or warranty claims, please contact the seller directly. A 24-hour response time is typically provided for inquiries.

Warranty and service information: 1 year warranty, 24 hrs response time

Figure 12: Warranty and Service Information

7. User Tips

  • Battery Compatibility: The inverter supports both 24V and 48V battery systems. Ensure your battery bank voltage matches the inverter model.
  • Operation Without Battery: The inverter is designed to work without a battery, directly utilizing solar power for loads.
  • EMI Considerations: Some users have reported Electromagnetic Interference (EMI) when a battery is attached. If you experience this, ensure proper grounding and shielding of cables.
  • BMS Port: The BMS (Battery Management System) port is used for communication with compatible smart batteries. Consult your battery manufacturer for compatibility and connection requirements.
  • Output Voltage: Verify the inverter's output voltage (110V or 220V) matches your regional requirements and connected appliances.

8. Applications

The SUMRY MPS VIII ECO series inverter is suitable for powering a wide range of appliances in various environments, including:

  • Home use
  • Recreational Vehicles (RV)
  • Boats
  • Outdoor activities
Images showing various applications: home, RV, boat, outdoor activities

Figure 13: Wide Application Field

Various home and office appliances that can be powered by the inverter

Figure 14: Appliances that can be powered


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.