SUMRY SP-3200, SP-4200

Contents

SUMRY SP Hybrid Solar Inverter User Manual

Models: SP-3200 (3KW), SP-4200 (3.8KW)

Pure Sine Wave MPPT Power Solar Inverter

1. Introduction

The SUMRY SP Hybrid Solar Inverter is a multi-function inverter/charger, combining the functions of an inverter, MPPT solar charger, and battery charger to offer uninterruptible power support in a portable size. It is designed to provide reliable power for various household appliances and is compatible with both lithium-ion and lead-acid batteries.

Key features include:

  • Pure sine wave output
  • Programmable supply priority for PV, battery, or grid
  • High PV input voltage range (55~450VDC)
  • Built-in Max 110A MPPT solar charge controller
  • Compatibility with lithium-ion batteries and support for BMS communication
  • Smart battery charge design to optimize battery life
  • Comprehensive protection: Overload, high temperature, inverter output short circuit, high/low voltage, battery protection, overcurrent, anti-reverse, power failure
  • Cold start function
  • Intelligent fan speed adjustment
  • Optional built-in anti-dusk kit for harsh environments
  • WIFI & GPRS monitoring available for iOS and Android
SUMRY SP Hybrid Inverter features overview with icons for PV input, battery voltage, AC output, waveform, MPPT controller, max PV voltage, max charging current, communication, and battery types.

Figure 1: Key Features Overview

2. Safety Information

Please read and understand all instructions and warnings before installing, operating, or maintaining this inverter. Failure to follow these instructions may result in electric shock, fire, or severe injury.

  • **Qualified Personnel**: Installation and wiring must be performed by qualified personnel.
  • **Flammable Materials**: Do not mount the inverter on flammable construction materials.
  • **Solid Surface**: Mount the unit on a solid surface.
  • **Eye Level**: Install this inverter at eye level to allow the LCD display to be read at all times.
  • **Air Circulation**: For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
  • **Ambient Temperature**: The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • **Vertical Installation**: The recommended installation position is to be adhered to the wall vertically.
  • **Clearance**: Be sure to keep other objects and surfaces clear as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
  • **Non-Combustible Surface**: Suitable for mounting on concrete or other non-combustible surfaces only.
  • **Voltage/Current Check**: To ensure user safety, use a multimeter to measure the voltage and current before connecting cables.
Diagram showing mounting clearances for the inverter: 20cm on sides, 50cm above and below.

Figure 2: Mounting the Unit with Recommended Clearances

3. Product Overview

3.1. External Components

Diagram of the inverter's external components with numbered labels.

Figure 3: Product Overview with Labeled Ports

  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons (ESC, UP, DOWN, ENTER)
  6. Power on/off switch
  7. AC input
  8. AC output
  9. PV input
  10. Battery input
  11. RS-232 communication port
  12. Safety (Earth) ground
  13. Circuit breaker

3.2. LCD Display and Function Keys

Detailed diagram of the LCD display and function keys with numbered indicators.

Figure 4: LCD Display and Function Keys

LCD Display Indicators
Indicator Status Message
AC / INV Green Solid On Output is powered by utility in Line mode.
Green Flashing Output is powered by battery or PV in battery mode.
CHG Green Solid On Battery is fully charged.
Green Flashing Battery is charging.
FAULT Red Solid On Fault occurs in the inverter.
Red Flashing Warning condition occurs in the inverter.
Function Keys Description
Function Key Description
ESC To exit setting mode
UP To go to previous selection
DOWN To go to next selection
ENTER To confirm the selection in setting mode or enter setting mode

4. Setup and Installation

4.1. Unpacking

Carefully unpack the inverter and inspect it for any damage. Ensure all components are present as per the packing list.

Video 1: Quick Installation Guide (0:00 - 0:17 shows unpacking)

4.2. Electrical Connection

Before making any electrical connections, ensure the inverter is turned off and disconnected from all power sources. Always verify voltage and current with a multimeter before connecting cables.

  1. **Open Bottom Case**: Use a screwdriver to open the bottom case of the inverter.
  2. **Prepare Wires**: Peel the wire insulation 10-15mm and fix it to the terminal holes with screws.
  3. **Battery Connection**: Connect the battery cables to the positive (+) and negative (-) terminals. Ensure correct polarity. The 1.8KW model supports a 12VDC system, and the 3KW model supports a 24VDC system.
  4. **PV Input Connection**: Insert the PV series connector into the AC connector of the inverter. Ensure the total power of solar panels does not exceed the maximum power of the inverter. PV cable dimensions should be 6-8mm².
  5. **Ground Connection**: Lock the ground cable to the corresponding hole.
  6. **AC Input/Output**: Connect AC input and output wiring as per local electrical codes.
  7. **Close Bottom Case**: Install the top cover and tighten the screws securely.
Diagram showing battery connection for 1.8KW/12V and 3.2KVA/24V inverter systems.

Figure 5: Battery Connection Diagram

Diagram showing solar panels connected in series to increase voltage, with PV cable dimensions of 6-8mm².

Figure 6: Solar Panel Series Connection

Refer to Video 1 (0:21 - 1:08) for a visual guide on electrical connections.

5. Operation

Once all electrical connections are secure, you can power on the inverter.

  1. **Power On**: Press the Power On/Off switch (refer to Figure 3, item 6).
  2. **LCD Interaction**: Use the function buttons (ESC, UP, DOWN, ENTER) to navigate through the LCD display menus and settings.
  3. **Monitoring**: The LCD display provides real-time information on PV input, AC input, voltages, currents, load levels, and operational status (refer to Figure 4).
  4. **Setting Programs**: Access setting programs (Figure 4, item 4) to configure parameters such as supply priority (PV, battery, or grid) and charging settings.

Refer to Video 1 (1:25 - 1:29) for a demonstration of running the inverter and interacting with the display.

6. WiFi Connection (Optional)

If your inverter model includes the WiFi option, you can connect a WiFi dongle for remote monitoring and control via a mobile application (iOS and Android compatible).

  1. **Insert WiFi Dongle**: Locate the communication port (RS-232) on the inverter (refer to Figure 3, item 11).
  2. **Connect**: Insert the WiFi dongle into the communication port.
  3. **App Setup**: Follow the instructions provided with your WiFi dongle and mobile application to complete the setup and connect to your inverter.

Refer to Video 1 (1:12 - 1:15) for a visual guide on connecting the WiFi dongle.

7. Specifications

The SUMRY SP Hybrid Solar Inverter is available in several models with varying power outputs and battery voltages. Please refer to the table below for detailed specifications.

Table of product parameters for SUMRY SP-2200, SP-3200, SP-4200, and SP-7000 models, including rated power, PV power, surge power, charging current, battery voltage, MPPT range, efficiency, dimensions, and net weight.

Figure 7: Product Parameters Table

Important Notes on Power Rating:

  • Ensure the inverter's power rating is higher than the appliance you intend to power.
  • It is recommended to purchase a larger model (at least 10% to 20% more than the maximum load) to ensure optimal performance and longevity.
  • If you plan to run multiple appliances simultaneously, refer to their total wattage to select an appropriately sized inverter.
  • For running inductive loads (e.g., motors, refrigerators) for extended periods, a pure sine wave inverter like this model is essential.

8. Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your SUMRY SP Hybrid Solar Inverter.

  • **Cleaning**: Periodically clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings are free from dust and debris.
  • **Connections**: Check all electrical connections regularly to ensure they are tight and free from corrosion.
  • **Environment**: Maintain the recommended operating environment (temperature, humidity, clearances) to prevent overheating.
  • **Battery Inspection**: If using external batteries, regularly inspect them for any signs of damage, leakage, or corrosion. Follow battery manufacturer's maintenance guidelines.

9. Troubleshooting

This section provides solutions to common issues you might encounter with your inverter. Refer to the LCD display for fault codes and warning conditions (Figure 4).

Common Troubleshooting Steps
Problem Possible Cause Solution
Inverter not turning on No battery power, loose connections, faulty power switch. Check battery connections and charge level. Ensure power switch is ON. Verify all wiring.
Overload warning/fault Connected load exceeds inverter capacity. Reduce the connected load. Ensure total wattage is within inverter limits.
High/Low Voltage fault Input voltage (PV or battery) is outside acceptable range. Check PV array voltage and battery voltage. Ensure they are within the inverter's operating range.
Overheating fault Insufficient ventilation, high ambient temperature. Ensure proper clearances around the inverter. Check for blocked vents. Reduce ambient temperature if possible.
No AC output Inverter in fault mode, AC output breaker tripped, no input power. Check LCD for fault codes. Reset AC output circuit breaker. Verify AC input power.
Icons representing various protection features: Overload, Overheating, High Low Voltage, Battery, Short Circuit, Overcurrent, Anti Reverse, Power Failure protection.

Figure 8: Inverter Protection Features

10. User Tips

  • **Power Rating Clarification**: Note that while some descriptions might mention 1000W, the actual rated output power for models like SP-3200 is 3000W and SP-4200 is 3800W. Always refer to the detailed specifications table for your specific model.
  • **WiFi Monitoring**: The inverter supports WiFi monitoring. Ensure you connect the optional WiFi module to utilize this feature for remote management.
  • **Battery System**: The 3KW model supports a 24VDC battery system, while other models may support 12VDC or 48VDC. Verify your battery voltage matches the inverter's requirements.

11. Warranty & Support

SUMRY products come with a 1-year warranty from the store. For any questions or technical assistance, please contact customer support. All questions will be answered within 24 hours.

Warranty and Service information: 1 year warranty, 24-hour shopping help response.

Figure 9: Warranty and Service Information

© 2023 SUMRY. All rights reserved.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.