SRNE LSW-5

SRNE LSW-5 Wi-Fi Monitor Module Instruction Manual

Brand: SRNE | Model: LSW-5

1. Introduction and Overview

The SRNE LSW-5 Wi-Fi monitor module is a wireless accessory designed to extend the Wi-Fi network data transmission channel for compatible devices. It is specifically engineered for remote monitoring of SRNE MPPT Hybrid Inverters (HF/ASF/ASP Series). This module features a robust four-pin aviation interface (RS-485) for secure connection, boasts an IP65 protection level for durability, and offers easy installation without the need for an additional power supply. It supports comprehensive remote control, debugging, and firmware upgrade functions, providing users with a low-cost, visual, and remote monitoring solution through a cloud server and the SOLARMAN Smart APP.

Important Compatibility Note: This Wi-Fi module is exclusively compatible with SRNE MPPT Hybrid Inverters (HF/ASF/ASP Series). It is NOT compatible with HES/HESP Series inverters.

2. Specifications

SRNE LSW-5 Product Parameters
CategoryParameterValue
Wireless ParameterWorking Frequency2.412GHz~2.472GHz
Transmit Power802.11b: +17 dBm±1.5dBm (@11Mbps)
802.11g: +15 dBm±1.5dBm (@54Mbps)
802.11n: +14 dBm±1.5dBm (@HT20, MCS7)
Antenna OptionEmbedded PCB antenna
Wireless Standard802.11 b/g/n
BluetoothWireless standardBLE5.0
Frequency range2.402GHz~2.480GHz
Transmit powerMAX15dBm
Data InterfaceRS485
Hardware ParameterWorking voltageDC5V ~ DC12V
Working power1.5W
Indicator LightOne connected to Inverter
One connected to router
One connected to heartbeat
Data StorageDefault: 8 MBYTE Flash
Working Temperature-30°C ~ +70°C
Working Humidity10%~90%, no condensation
Storage Temperature-45°C ~ +90°C
Storage Humidity<90%
External InterfaceSmall Aviation Head
No. of connectionsOne
Software ParameterSerial Communication RateDefault: 9600bps (1200-115200bps optional)
Data Transmission IntervalDefault: 5 mins (1-15 mins optional)
ConfigurationAT+Instruction set, Local web configuration, Remote server, Bluetooth
Firmware UpgradeLocal web upgrade, Remote update
OthersFeaturesReal-time Control, Data Resuming

Physical Dimensions:

  • Size: 70mm x 40mm x 150mm
  • Net Weight: 150g

3. Setup Instructions

3.1 Hardware Installation

  1. Install Fixed Bracket: Install the provided fixed bracket securely on the wall adjacent to your SRNE MPPT Hybrid Inverter.
  2. Connect Data Logger: Connect the SRNE LSW-5 Wi-Fi monitor module to the inverter using the data cable. Ensure the connection is firm and tighten it.
SRNE LSW-5 Stick Logger Quick Guide showing installation steps

Figure 3.1: Quick Guide illustrating installation steps and warnings.

SRNE LSW-5 WIFI monitor module with connection cable

Figure 3.2: SRNE LSW-5 Wi-Fi Monitor Module with its connection cable.

SRNE LSW-5 WIFI monitor module with cable and mounting bracket

Figure 3.3: SRNE LSW-5 Wi-Fi Monitor Module, cable, and mounting bracket.

3.2 System Connection Diagram

The diagram below illustrates the typical system architecture for the SRNE LSW-5 Wi-Fi monitor module, showing how it integrates with inverters, a router, and the cloud server for remote monitoring via web or mobile application.

System connection diagram for SRNE LSW-5 Wi-Fi module with inverters, router, cloud server, web, and app

Figure 3.4: System Connection Diagram.

3.3 App Download and Account Setup

To utilize the remote monitoring features, download and set up the SOLARMAN Smart APP:

  1. Download the App:
    • Android: Search for "SOLARMAN Smart" in your application market/store.
    • iOS: Download "SOLARMAN Smart APP" from the Apple App Store.
    • Alternatively, scan the QR code provided below with your mobile phone for direct download.
  2. Account Registration/Login:
    • Experience Account: For quick access to app functions, an experience account is available. Contact customer service for details.
    • New Account: Register a new account in SOLARMAN Smart APP and complete the required information. After successful registration, log in via the "Login Method" through the APP application login page.
    • If you have a completed account registration in SOLARMAN Smart Web, you can directly enter the corresponding account and password to log in and select "Create a Plant".
SOLARMAN Smart APP overview and QR code for download

Figure 3.5: SOLARMAN Smart APP Overview and Download QR Code.

SOLARMAN Smart APP login, registration, and business section introduction

Figure 3.6: SOLARMAN Smart APP Account Setup and Business Section.

4. Operating Instructions

The SRNE LSW-5 module enables comprehensive remote monitoring and management of your solar power system through the SOLARMAN Smart APP.

4.1 SOLARMAN Smart APP Functions

  • Power Station Data Monitoring: The app provides intuitive and comprehensive data monitoring for your power station terminals.
  • Real-time Monitoring: View and manage real-time data, equipment status, and authorization information of your power station.
  • System Layout: The app displays the system layout in an intuitive picture, aiding in visual management.
  • Alarms: Receive power station alarms to ensure timely operation and maintenance, optimizing power generation efficiency.
  • Remote Control & Debugging: The module supports remote control and debugging of the connected inverter.
  • Firmware Upgrades: Perform remote firmware updates for the device.

4.2 App Sections Overview

  • Plant Section: This function module allows you to quickly obtain summary statistics of equipment and power generation data, monitor real-time power station transformation, view and manage data, equipment, and authorization information. It displays the system layout intuitively and ensures daily operation and maintenance through power station alarms, effectively managing power generation efficiency.
  • Me Section: In this section, users can view and operate personal information, basic settings, and other account functions. This helps manage basic information and provides access to online customer service for inquiries.

5. Maintenance

To ensure the longevity and optimal performance of your SRNE LSW-5 Wi-Fi monitor module, follow these maintenance guidelines:

  • Physical Handling: When installing or removing the logger, avoid holding the logger body to rotate it. Always handle it carefully.
  • Waterproof Plug: Do not remove the waterproof plug from the device, as this will compromise its IP65 protection and may lead to damage.
  • Cleaning: Keep the module clean and free from dust. Use a soft, dry cloth for cleaning. Do not use liquid cleaners or solvents.
  • Environmental Conditions: Ensure the module operates within its specified working temperature (-30°C to +70°C) and humidity (10%~90%, non-condensing) ranges.

6. Troubleshooting

This section provides guidance for diagnosing and resolving common issues with your SRNE LSW-5 Wi-Fi monitor module.

6.1 Indicator Light Status

The module features three indicator lights: NET, COM, and READY. Their status provides crucial information about the device's operation:

  • NET Light:
    • OFF: No power supply or communication failure with the router.
    • Slow flash: Communicating with the router.
    • Fast flash: Communicating with the server.
  • COM Light:
    • OFF: No power supply or communication failure with the inverter.
    • Slow flash: Communicating with the inverter.
    • Fast flash: Communicating with the inverter.
  • READY Light:
    • OFF: No power supply or communication failure.
    • Slow flash: Communicating with the inverter.
    • Fast flash: Communicating with the inverter.

6.2 Abnormal State Processing

Refer to the table below for common abnormal states, their causes, and recommended solutions:

Troubleshooting Guide
StatusFault DescriptionFault CauseSolution
NET OFFCommunication failure with router1. Connection between stick logger and router.
2. Router not working.
1. Check the connection between stick logger and router.
2. Check router status.
NET Slow flashCommunication failure with server1. Connection between stick logger and server.
2. Server not working.
1. Check the connection between stick logger and server.
2. Check server status.
COM OFFCommunication failure with inverter1. Connection between stick logger and inverter.
2. Inverter not working.
1. Check the connection between stick logger and inverter.
2. Check inverter status.
COM Slow flashCommunication failure with server1. Connection between stick logger and server.
2. Server not working.
1. Check the connection between stick logger and server.
2. Check server status.
READY OFFNo power supply1. Power supply failure.
2. Stick logger failure.
1. Check power supply.
2. Replace stick logger.
READY Slow flashCommunication failure with inverter1. Connection between stick logger and inverter.
2. Inverter not working.
1. Check the connection between stick logger and inverter.
2. Check inverter status.
READY Fast flashCommunication failure with server1. Connection between stick logger and server.
2. Server not working.
1. Check the connection between stick logger and server.
2. Check server status.

6.3 Button Functions

The module has a button with the following functions:

  • Press: Initiates a reboot of the stick logger.
  • Long press for 5 seconds: Restores the device to factory settings.

7. User Tips

  • Inverter Compatibility: Always verify that your SRNE inverter model is from the HF/ASF/ASP series to ensure compatibility with the LSW-5 Wi-Fi module. This module is not compatible with HES/HESP series inverters.
  • Network Stability: A stable Wi-Fi network connection is crucial for reliable remote monitoring. Ensure your router is functioning correctly and provides adequate signal strength to the module.
  • App Updates: Keep the SOLARMAN Smart APP updated to the latest version to benefit from new features, bug fixes, and improved performance.

8. Warranty and Support

For specific warranty information regarding your SRNE LSW-5 Wi-Fi monitor module, please refer to the documentation provided at the time of purchase or contact your seller directly. In case of technical issues not covered in this manual's troubleshooting section, please reach out to SRNE customer support or your product vendor for assistance.

Related Documents - LSW-5

Preview SRNE HYP Series All-in-One Solar Storage Inverter User Manual
Comprehensive user manual for the SRNE HYP Series all-in-one solar storage inverter, covering installation, operation, safety, technical parameters, and troubleshooting for models HYP4850S100-H and HYP4850U100-H.
Preview SRNE Mobile App Quick Guide
A quick guide to downloading, connecting, and using the SRNE mobile application for monitoring SRNE devices, including setup, viewing data, and providing feedback.
Preview SRNE IU Series High-Frequency Pure Sine Wave Inverter User Manual
Comprehensive user manual for the SRNE IU Series high-frequency pure sine wave inverter. Details product overview, features, specifications, interface functions, installation procedures, protection mechanisms, troubleshooting, and system maintenance for models IU12-2KW and IU24-3KW.
Preview SRNE HF4850U80-H All-in-one Solar Charge Inverter User Manual
Comprehensive user manual for the SRNE HF4850U80-H All-in-one Solar Charge Inverter. This guide provides detailed information on installation, operation, safety precautions, protection functions, system maintenance, and technical specifications for efficient solar energy management.
Preview SRNE HSI 5500P Solar Storage Inverter User Manual
Comprehensive user manual for the SRNE HSI 5500P Solar Storage Inverter, detailing safety, installation, operation, and technical specifications for efficient solar energy management.
Preview SRNE SPI-8K-UP & SPI-10K-UP Solar Charge Inverter User Manual
Comprehensive user manual for SRNE SPI-8K-UP and SPI-10K-UP All-in-one Solar Charge Inverters. This guide covers installation, wiring, operation, safety, and maintenance for efficient solar energy management, suitable for residential and light commercial applications.