JOYELEC SS766N

Contents

JOYELEC SS766N Series Digital Single Phase Energy Meter User Manual

Model: SS766N, SS766NM, SS776NMR, SS766NL

1. Product Overview

The JOYELEC SS766N series is a range of digital single-phase electronic energy meters designed for measuring active energy (kWh), voltage, current, and power consumption in AC electrical systems. These meters are suitable for 35mm DIN rail installation and feature a digital display for clear readings. Different models offer varying functionalities such as backlight, temporary energy reset, and multi-interface display.

JOYELEC Single Phase Electronic Meter displaying power consumption, voltage, current, and power

Figure 1: JOYELEC Single Phase Electronic Meter displaying various parameters.

2. Specifications

FeatureSpecification
Model NumberSS766N (Series includes SS766NM, SS776NMR, SS766NL)
Output Voltage220V AC
Rated Voltage230V
Power SupplyAC
Max Operating Current60A (Range 50A - 79A)
Measuring Energy Range0.0 - 99999.9 kWh
PhaseSingle Phase
Display TypeDigital Only (LCD)
Pulse Frequency1600 imp/kWh
Installation35mm DIN Rail
CertificationCE
DIY SuppliesElectrical
Dimensions of the energy meter (front and side views)

Figure 2: Product dimensions for installation planning.

3. Setup and Installation

Safety First: Before beginning any electrical installation, ensure that the main power supply is turned OFF at the circuit breaker to prevent electric shock.

  1. Mounting: The energy meter is designed for 35mm DIN rail installation. Securely clip the meter onto the DIN rail in your electrical panel.
  2. Wiring: Follow the wiring diagram carefully. Connect the Live (L) and Neutral (N) wires from your power source to the corresponding input terminals of the energy meter. Then, connect the output terminals of the energy meter to your electrical equipment.
Wiring diagram for the energy meter, showing connection to a power switch and electrical equipment

Figure 3: Wiring Diagram. Connect the power switch to the meter, and the meter to the electrical equipment.

  • Ensure all connections are tight and secure to prevent loose contacts and potential hazards.
  • Verify that the voltage of your electrical system matches the meter's specifications (220V AC).

After installation, restore power to the circuit. The meter should power on and begin displaying readings.

4. Operating Instructions

The energy meter provides various readings on its digital display, which typically cycles automatically through different parameters.

Display Modes:

  • Total Energy (kWh): This value represents the cumulative power consumption and cannot be reset.
  • Temporary Energy (kWh): This value can be reset, allowing you to measure power consumption over specific periods.
  • Real Voltage (V): Displays the current voltage of the circuit.
  • Real Current (A): Displays the current flowing through the circuit.
  • Real Power (W): Displays the instantaneous power consumption.

Model-Specific Features:

  • SS766NM: Displays total and temporary power consumption, and automatically cycles through voltage, current, and power. Temporary kWh can be reset by reconnecting the consumer (power cycling the meter).
    SS766NM model showing total and temporary power consumption

    Figure 4: SS766NM display indicating total and temporary kWh.

  • SS776NMR: Features a dedicated Reset button to clear the temporary energy (kWh) reading. It also offers three interface switching for voltage, current, and power.
    SS776NMR model with a reset button and display modes

    Figure 5: SS776NMR model highlighting the reset button.

  • SS766NL: Features an LCD display with backlight and shows only total power consumption (kWh).
    SS766NL model displaying total power consumption with backlight

    Figure 6: SS766NL model with backlight showing total kWh.

  • SS766N: Features an LCD display without backlight and shows only total power consumption (kWh).
    SS766N model displaying total power consumption without backlight

    Figure 7: SS766N model without backlight showing total kWh.

Pulse LED Indicator:

A pulse LED on the meter indicates its operational status and active energy measurement. It flashes at a rate of 1600 pulses per kWh, providing a visual confirmation of energy consumption.

5. Maintenance

The JOYELEC SS766N series energy meters are designed for long-term, maintenance-free operation under normal conditions.

  • Cleaning: To clean the meter, gently wipe the exterior with a soft, dry cloth. Do not use abrasive cleaners, solvents, or liquids, as these can damage the display or internal components.
  • Inspection: Periodically inspect the wiring connections to ensure they remain secure and free from corrosion.
  • No User-Serviceable Parts: The meter contains no user-serviceable parts. Do not attempt to open or repair the device, as this will void the warranty and could lead to electrical hazards.

6. Troubleshooting

  • No Display/Meter Not Powering On:
    • Ensure the main power supply to the circuit is ON.
    • Check all wiring connections (Live and Neutral) for proper contact and polarity. Incorrect wiring is a common cause.
    • Verify that the input voltage is within the meter's specified operating range (220V AC).
  • Incorrect Readings:
    • Double-check the wiring according to the diagram. Incorrect current path can lead to inaccurate measurements.
    • Ensure the meter is correctly rated for the load it is measuring (Max Operating Current 60A).
  • Temporary kWh Not Resetting (SS766NM):
    • For models without a dedicated reset button (e.g., SS766NM), the temporary kWh is typically reset by power cycling the meter (disconnecting and reconnecting the power supply to the meter).
  • Meter Requires Both Live and Neutral Wires:
    • This meter is designed for single-phase AC systems and requires both a Live (L) and Neutral (N) connection to function correctly. It cannot operate with only a single live wire.

7. Warranty and Support

This JOYELEC energy meter is CE certified, indicating compliance with European safety, health, and environmental protection requirements.

For technical support, warranty claims, or further assistance, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

8. User Tips

  • Resetting Temporary Readings: If you frequently need to reset temporary power consumption readings, consider models like the SS776NMR which feature a convenient reset button. For other models, a power cycle of the meter is usually required.
  • Voltage Compatibility: This meter is designed for 220V AC systems. Ensure your electrical supply matches this specification for proper and safe operation. It is not compatible with 110V systems.
  • Monitoring Specific Loads: Use the temporary kWh feature (if available on your model) to monitor the energy consumption of specific appliances or circuits over a defined period.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.