1. Product Introduction
Thank you for purchasing our product. This manual provides instructions for installing and operating the controller. Please read it carefully before any work and keep it for future reference. The contents may be updated or revised; please refer to the actual product.
This hybrid wind solar charge controller is specifically designed for small off-grid systems, such as street lamps or monitoring systems. It efficiently charges batteries from both wind generators and solar panels. It is compatible with Lithium, GEL, and Lead-acid batteries, offering comprehensive charge and discharge protection. The large LCD screen allows for easy parameter monitoring and adjustment with low power consumption. Its robust functions and excellent heat dissipation make it suitable for flexible installation in various environments like cruise ships, RVs, and indoor settings.
1.1 Key Features
- Wind generator MPPT boost charging function.
- PWM dump load for wind, external dump-load resistance, intelligent disconnection of Solar charging.
- Dual power supply function: Battery + solar power supply.
- LCD displays parameters such as voltage and current of wind, solar, and load. Some parameters are user-adjustable.
- DC output with 3 output modes.
- Inner circuit board sprayed with conformal coating to prevent dust, moisture, and static electricity.
- High performance and stable chip control.
- Automatically matches 12V/24V or 24V/48V sealed battery voltage.
- Compatible with Sealed (Lead-acid, GEL) and Lithium (Ternary Lithium, Lithium iron) batteries.
- Controller body made of aluminum alloy for excellent heat dissipation, with convection grooves at the bottom.
1.2 Built-in Smart Bluetooth (Optional)
The Bluetooth module is directly integrated into the controller (available in Bluetooth versions). No additional Bluetooth devices are needed. Simply turn on your mobile phone's Bluetooth and download the mobile APP to quickly connect to the controller's network system. Currently, the device supports Android systems only, not iOS. The APP allows you to monitor the controller's working conditions, such as wind energy, solar energy, and battery voltage, helping to identify abnormalities in time. The effective monitoring range is within 200 meters.
Video: Demonstrating the mobile APP interface for monitoring the hybrid controller.
2. General Safety Information
- Before receiving, inspect the product for transport damage. Contact the shipping company or our company immediately if damaged.
- All installation and electrical work must be performed by professional personnel.
- Do not disassemble or attempt to repair the controller without professional guidance.
- Do not use the controller without batteries.
- Do not disconnect the controller and batteries while the controller is operating normally.
- Keep children away from the controller.
- Do not allow water to enter the controller.
- Ensure power connections are tightened to prevent excessive heating from loose connections. Use appropriate cables for the system.
2.1 Protection Features
| Protection | Explanation |
|---|---|
| Reversed charging Protection of solar | Prevents battery charging from the solar panel when battery voltage is higher than solar panel voltage (e.g., at night). |
| Reverse polarity Protection of battery | If battery polarity is reversed, the controller will not work and show no display. An internal fuse protects the circuit. If the battery doesn't work after correct connection, replace the fuse. |
| Battery open circuit Protection | Protects the controller from damage if the battery has an open circuit or poor connection. Check connections regularly. |
| Over voltage, Over current, Over load voltage Protection | Automatically activates braking for the wind generator and cuts off the circuit if output is over voltage or strong wind/over voltage. |
| Lightning Protection | Last level of protection. For lightning-prone areas, special multi-level lightning protection devices may be needed (additional cost). |
3. Installation and Electrical Connection
3.1 Mounting Notes
- Read this entire section before installation.
- All mounting work must be performed by professional personnel.
- Disconnect all power sources to the controller before installing or adjusting.
- Do not allow water or snow to enter the controller.
- Keep away from corrosive gases and strong electromagnetic interference.
- The installation site should be convenient for installation, electrical connection, and later maintenance.
3.2 Controller Dimensions

Image: Controller dimensions showing height, width, and depth.
3.3 Wiring Steps
Follow the suggestions and steps below to connect the system components.
3.3.1 Dump Load Wiring
This controller uses an external dump load. Connect the dump load positive (+) and negative (-) terminals to the controller as shown in the diagram.

Image: Diagram showing how to connect the external dump load to the controller.
3.3.2 Battery Wiring
Connect the battery positive (+) and negative (-) terminals to the controller as shown. Ensure connections are secure to avoid short circuits. Anti-connecting of positive and negative terminals is forbidden, even with built-in protection.

Image: Diagram showing how to connect the battery to the controller.
Important: The solar PV array can produce high voltages in sunlight. Exercise caution to avoid electric shock when wiring. Although the controller has solar anti-reverse protection, anti-connecting positive (+) and negative (-) is forbidden.
Video: Step-by-step guide on connecting the battery to the hybrid controller.
3.3.3 Solar Panel Wiring
Connect the solar panel positive (+) and negative (-) terminals to the controller as shown. Be careful of electric shock when wiring due to potentially high voltages from the solar PV array.

Image: Diagram showing how to connect the solar panel to the controller.
3.3.4 Wind Generator Wiring
Connect the wind generator to the controller as shown. Wind generators can produce high voltages, so be careful of electric shock. It is safer to connect the wind generator when there is little to no wind. A high-speed rotating wind generator should only be connected when the controller is already working.

Image: Diagram showing how to connect the wind generator to the controller.
3.3.5 Load Wiring
Connect the load positive (+) and negative (-) terminals to the controller as shown. Be careful to avoid short circuits when wiring loads. Anti-connecting of positive and negative terminals is forbidden. The load current should not exceed the rated load current.

Image: Diagram showing how to connect the load to the controller.
4. Operation
4.1 Button Descriptions
| Item | Description |
|---|---|
| ENTER | Long press for >3s in browsing interface to enter parameter setting. Press to switch to next setting item. Long press for >3s in setting interface to save parameters and exit. |
| UP | In browsing interface, switch to previous item. In setting interface, increase parameter value (long press for quick adjust). |
| DOWN | In browsing interface, switch to next item. In setting interface, decrease parameter value (long press for quick adjust). |
| ESC | In browsing interface, return to main browsing interface. In setting interface, switch to previous setting item. Long press for >3s to exit setting state without saving. In main browsing interface, long press for 5s to switch to Chinese. |
Note: If no key is pressed within one minute, modified parameters will not be saved, and the interface will automatically return to the main browsing interface.
4.2 Browsing Interfaces
After powering on, the LCD will display the default browsing interface. Use UP or DOWN keys to switch between items (battery, solar panels, fan, load, temperature). The display contents are as follows:

Image: Example of the LCD browsing interface.
| Item | Icon | Description |
|---|---|---|
| 1 | ☀️ | Day |
| 🌙 | Night (also displayed if no PV connected) | |
| 2 | 🌬️ | Wind turbine charging when rotating |
| CHARGE (arrow flash) | PV and wind turbine charging normally | |
| BRAKE | Wind turbine brake, usually for 10 minutes | |
| 4 | 🔋 | Battery pattern showing power. Flashes during over-discharge protection, returns to normal when voltage is higher than recovery voltage. |
| OUTPUT (arrow flash) | Controller load output status is normal | |
| BAT: 0 A | Display of current browsing content parameters |
4.2.1 Displayed Parameters
| Battery | PV | Wind Turbine | Load | Temperature |
|---|---|---|---|---|
| **V-Battery Voltage | **V-PV Voltage | **V-wind turbine voltage | **MODE-output operation loads | **-Controller Temperature |
| **%-Battery Capacity | **A-PV current | **A-wind turbine current | **W-load power | P**-Temperature code |
| **A-Battery Current | **W-PV power | **W-wind turbine power | **A-load current | |
| **W-Battery Power | **LO-Load fault code | |||
| **KWH-cumulative output |
4.2.2 Load and Temperature Code Meanings
| Load Code | Description | Temperature Code | Description |
|---|---|---|---|
| L0 | Normal | P0 | Normal |
| L1 | Manual closing state | P1 | Low temperature state |
| L2 | Over discharge protection | P2 | High temperature state |
| L3 | Over current protection | P3 | Protection state |
| L4 | Over voltage protection | P4 | Abnormal |
5. Parameter Setting
5.1 Operating Instructions
- Long press the ENTER key for more than 3 seconds in any browsing interface to enter the parameter setting interface.
- Press the ENTER key to move to the next parameter setting item. Press the ESC key to move to the previous parameter setting item.
- When a parameter is flashing:
- Press UP to increase the value (long press for quick adjustment).
- Press DOWN to decrease the value (long press for quick adjustment).
- After setting parameters, long press the ENTER key for more than 3 seconds to save the parameters and exit the setting state.
- After setting parameters, long press the ESC key for more than 3 seconds to exit the setting state without saving the parameters.
5.2 Settable Parameters
| Item | Display | Description | Options / Notes |
|---|---|---|---|
| 1 | SYS 12/24 AUTO | Rated voltage of battery | 12: lock 12V system; 24: lock 24V system; AUTO: automatic recognition |
| 2 | TYPE: b0 | Type of battery | b0: customization; b1: Gel battery; b2: Ternary lithium battery; b3: Lithium iron phosphate battery. When set to b0, each voltage can be set by the user. When set to b1/b2/b3, the controller automatically matches default values. |
| 3 | LOW: ***V | Over discharge protection voltage | |
| 4 | RLOW: ***V | Over discharge recovery voltage | |
| 5 | FULL: ***V | Over charge protection voltage | |
| 6 | UL: **V | Light control voltage | Voltage to judge day/night. One minute delay. |
| 7 | ON/OFF | Solar charge switch | |
| 8 | ON/OFF | Wind turbine charge switch | |
| 9 | ON/OFF | Load output switch | |
| 10 | MODE: * | Load mode | Mode 1: Light-control on, off at day, 100% power. Mode 2: Always on, 100% power. Mode 3: Light control + time control (load on at dark, work according to set time/power, four sections + morning light adjustable). |
| 11-17 | T1-T4, P1-P4 | Time phases and power for load | Adjustable from 0-900 minutes and 0-100% power. In Mode 3, if the first working time is 2 minutes and power is 0%, the system delays 2 minutes before turning on the light after dark (street lamp mode). |
| 18 | P4: ***% | Power in fourth time phase | |
| 19 | TC: ***min | Morning time phase | Eliminates light differences between front/rear lights caused by solar panels in different street lamps. |
| 20 | PC: ***% | Power in time phase |
6. Troubleshooting
| Question | Answer |
|---|---|
| When the wind generator is connected to the controller, it becomes very slow immediately. |
|
| Why does the wind generator dump load when the controller displays small current? | The controller protects the system by detecting battery voltage, charging current, and temperature. When the battery reaches floating charge voltage or high temperature, the wind generator will dump load, regardless of charging current. |
| LCD does not display. |
|
| No charging current. | Charging only occurs when the input voltage of solar panels and wind generator is higher than the battery voltage. |
7. Specifications
7.1 Battery Parameters (12V/24V System)
| Function | FULL (Charging protection) | LOW (Load disconnect) | RLOW (Load connect) |
|---|---|---|---|
| Customization (b0) | 14.7V/29.4V (adjustable) | 10.2V/20.4V (adjustable) | 11.5V/23.0V (adjustable) |
| Lead acid/Gel Battery (b1) | 14.4V/28.8V (default) | 10.2V/20.4V (default) | 11.5V/23.0V (default) |
| Ternary lithium battery (b2) | 12.6V/25.2V (default) | 9.0V/18.0V (default) | 10.0V/20.0V (default) |
| Lithium iron phosphate battery (b3) | 14.4V/28.8V (default) | 10.0V/20.0V (default) | 11.0V/22.0V (default) |
7.2 Battery Parameters (24V/48V System)
| Function | FULL (Charging protection) | LOW (Load disconnect) | RLOW (Load connect) |
|---|---|---|---|
| Customization (b0) | 29.4V/58.8V (adjustable) | 20.4V/40.8V (adjustable) | 23.0V/46.0V (adjustable) |
| Lead acid/Gel Battery (b1) | 29.4V/58.8V (default) | 20.4V/40.8V (default) | 23.0V/46.0V (default) |
| Ternary lithium battery (6S/13S) (b2) | 25.2V/54.6V (default) | 18.0V/39.0V (default) | 20.0V/43.4V (default) |
| Lithium iron phosphate battery (8S/16S) (b3) | 28.8V/57.6V (default) | 20.0V/40.0V (default) | 22.0V/44.0V (default) |
7.3 Controller System Parameters
| Parameter | 12V/24V AUTO | 24V/48V AUTO Match |
|---|---|---|
| Model | TGR-700W, TGR-1200W, TGR-1600W, TGR-2000W | TGR-1200W, TGR-1600W, TGR-2000W, TGR-2400W, TGR-3000W |
| Battery voltage | 12V, 24V | 24V, 48V |
| Rated wind power | 200W-500W (12V), 400W-1000W (24V) | 300W-800W (24V), 600W-1600W (48V) |
| Rated PV power | 150W-500W (12V), 300W-1000W (24V) | 300W-800W (24V), 600W-1500W (48V) |
| Max input current | Wind turbine ≤40A, Solar panel ≤30A | Wind turbine ≤31.25A, Solar panel ≤30A |
| Max input voltage | Wind turbine ≤80V, Solar panel ≤55V | Wind turbine ≤80V, Solar panel ≤95V |
| DC Output | 20A | |
| No-load Current (DC) | ≤0.05A | |
| Controller power mode | Battery or solar | |
| Control mode | Wind generator MPPT boost charge, PWM dump load, PWM Over current Limiting function, solar power is PWM | |
| Supported battery types | 1. Lead acid battery 2. Ternary lithium battery 3. Lithium iron phosphate | |
| Output working mode (Mode) | Mode 1: Light-control on. Light-control off (3 modes adjustable) | |
| Display content | LCD display, Voltage, Percentage of battery power, Current, working mode of load, etc | |
| Protection type | Solar Reversed Charging protection, Battery open circuit protection, battery anti-reverse connection protection, Over current and over voltage auto brake protection, Over load protection, etc. | |
| Cooling mode | Aluminium profiles Heat dissipation and self-cooling | |
| Working temperature / Relative humidity | -25°C~+80°C / 0~90%, non-condensing | |
| Net weight / Gross weight | 2.1/2.35kg | |
| Controller size/Pack size | 167mm*145.5mm*61.8mm / 360mm*250mm*120mm | |
8. User Tips
- Ensure all connections are tight and correct to prevent issues like slow wind generator speed or no charging.
- Regularly check battery connections and condition, as a damaged battery can prevent the LCD from displaying.
- If the wind generator seems slow, check if the battery is at floating voltage or if the dump load MOS is faulty.
- For optimal charging, ensure solar panel and wind generator input voltages are higher than the battery voltage.
- Consider the Bluetooth version for convenient mobile monitoring of system parameters.
9. Warranty and Support
9.1 Warranty
The product is warranted for one year from the date of shipment to the original end user. During the warranty period, if a failure occurs under normal use, our company will repair or replace the product. After the warranty period, repair services are available for a charge.
This warranty is only provided to buyers who purchased the product directly from us and is non-transferable. Our company reserves the right to change products without notice during updates.
This warranty does not apply under the following conditions:
- Damage due to not operating in accordance with the user manual.
- Damage by accident, negligence, abuse, or improper use.
- Unauthorized product modification or attempted repair.
- Damage occurring during shipment.
9.2 Support
For further assistance or inquiries, please refer to the official user manual PDF: User Manual (PDF).