Interest Maker KWS-AC301

Contents

KWS-AC301 Wattmeter Power Meter User Manual

Model: KWS-AC301

Brand: Interest Maker

1. Product Overview

The KWS-AC301 Wattmeter Power Meter is a versatile AC electricity meter designed to measure and display various electrical parameters. It features a full-view color screen for clear observation and is built with PVC flame retardant material for stable and safe installation. This device is suitable for a wide range of applications, helping users monitor and manage electricity consumption efficiently.

KWS-AC301 Wattmeter Power Meter with accessories

Figure 1: KWS-AC301 Wattmeter Power Meter and included accessories.

1.1 Key Features

  • Measures 8 major functions: Current, Timing, Electrical Energy, Voltage, Power, Temperature, Power Factor, and Frequency.
  • Constructed with PVC flame retardant material for enhanced safety.
  • Features an all-round buckle design for stable installation.
  • Equipped with a full-view color screen for clear and easy-to-read data.
  • Utilizes a dedicated metering chip for accurate and fast data calculation.

1.2 Display Functions

KWS-AC301 display showing various measurements

Figure 2: KWS-AC301 display with labeled measurements.

  1. Voltage (V)
  2. Current (A)
  3. Timing (T)
  4. Electric Energy (Kwh)
  5. Power (W)
  6. Power Factor (PF)
  7. Frequency (Hz)
  8. Temperature (°C)

2. Package Contents

The package includes the KWS-AC301 Wattmeter Power Meter and accessories depending on the selected model (20A or 100A). Please verify all components are present upon unboxing.

KWS-AC301 20A model package contents

Figure 3: KWS-AC301 20A model and its accessories.

  • KWS-AC301 Wattmeter Power Meter
  • Temperature sensor cable (approx. 100cm length)
  • Current Transformer (CT) - type varies by model:
    • 20A Model: Built-in diversion method (no external CT)
    • 100A Close Transformer Model: External closed-loop CT
    • 100A Opening Transformer Model: External open-loop CT
  • Instruction Manual

3. Installation and Wiring

WARNING: Installation should only be performed by qualified personnel. Ensure power is disconnected before any wiring to prevent electric shock.

3.1 Dimensions

KWS-AC301 dimensions and current transformer types

Figure 4: Dimensions of the KWS-AC301 meter (76.4*48*23.4MM) and details of the 100A Close and Opening current transformers.

The meter dimensions are 76.4mm (length) x 48mm (width) x 23.4mm (depth). The 100A Close transformer has dimensions of 46.6mm x 30mm with a 15mm inner diameter. The 100A Opening transformer has a 14.8mm inner diameter.

3.2 Wiring Diagrams

Refer to the following diagrams for correct wiring based on your model. The meter has an alarm sound hole for audible alerts.

Wiring diagrams for KWS-AC301 20A and 100A models

Figure 5: Wiring diagrams for KWS-AC301-20A (top) and KWS-AC301-100A (bottom) models. Note the alarm sound hole location.

3.2.1 KWS-AC301-20A Model (Built-in Current Measurement)

For the 20A model, current measurement is built-in. Connect the Live (L) and Neutral (N) wires from your AC source (50-300V) to the "IN-AC" terminals (terminals 3 and 4). Connect your load to the "OUT LOAD" terminals (terminals 1 and 2). Ensure correct polarity (L to L, N to N).

Video 1: Demonstration of unboxing and connecting the 20A model.

3.2.2 KWS-AC301-100A Models (External Current Transformer)

For the 100A models, an external Current Transformer (CT) is used. Connect the Live (L) and Neutral (N) wires from your AC source (50-300V) to the "IN-AC" terminals (terminals 3 and 4). Connect your load to the "LOAD" terminals (terminals 1 and 2). The CT should be installed around the Live (L) wire of the circuit you wish to measure. Connect the CT's wires to the "CT" terminals on the meter. Ensure the CT is correctly oriented as per its markings (if any) and the wiring diagram.

KWS-AC301 100A Close transformer model package contents

Figure 6: KWS-AC301 100A Close transformer model and its accessories.

Video 2: Demonstration of unboxing and connecting the 100A Close transformer model.

KWS-AC301 100A Opening transformer model package contents

Figure 7: KWS-AC301 100A Opening transformer model and its accessories.

Video 3: Demonstration of unboxing and connecting the 100A Opening transformer model.

4. Operation

The KWS-AC301 features three buttons: Up (Δ), Mode (M), and Down (∇) for navigation and settings.

KWS-AC301 button functions diagram

Figure 8: KWS-AC301 button functions.

4.1 Basic Navigation and Clearing

  • Single click 'M': Zero clearing (T or Kwh) or move position in settings.
  • Double click 'M': Jump position in settings.
  • Press and hold 'M' for 3 seconds: Enter the setting interface for alarm values.
  • Press and hold 'Δ' for 3 seconds: Zero clearing (T or Kwh).

4.2 Alarm Settings

The meter allows you to set alarm values for various parameters. When the actual measured value meets or exceeds the set alarm value, the instrument will emit a sound warning, and the numerical unit on the screen will flash.

KWS-AC301 alarm setting interface

Figure 9: Visual representation of alarm setting process.

  1. Enter Settings: Press and hold the 'M' key for 3 seconds.
  2. Navigate: Use 'M' (single click) to shift between digits or parameters, and 'M' (double click) to jump positions. Use 'Δ' (Up) and '∇' (Down) keys to adjust the values.
  3. Save Settings: After setting the desired alarm values, press and hold the 'M' key for 3 seconds to save.
  4. Turn off Alarm: To disable an alarm, set its value higher than any expected actual value, or set the alarm value to 0.

4.3 Reset Functions

  • Electric Energy and Timing Reset:
    1. Press and hold the 'Δ' (Up) button for 3 seconds until the timing value flashes.
    2. Click the 'M' button to clear the timing.
    3. Double-click the 'M' button to wrap to the electric energy display.
    4. Click the 'M' button again to clear the electric energy value.
  • Factory Reset:
    1. Ensure the meter is powered off.
    2. Press and hold the '∇' (Down) key.
    3. While holding '∇', turn on the power.
    4. Release the '∇' key after hearing a sound from the instrument, indicating successful recovery.

    Note: The factory default voltage alarm value is 275V; all other alarm values are reset to 0.

5. Specifications

The KWS-AC301 Wattmeter Power Meter comes in different current capacities. Below are the detailed specifications:

KWS-AC301 specifications table for 20A and 100A models

Figure 10: Detailed specifications for KWS-AC301-20A and KWS-AC301-100A models.

FeatureModel: AC301-20AModel: AC301-100A
Diversion methodBuilt-inExternal
VoltageAC 50-300VAC 50-300V
Current0-20A0-100A
Electric energy0.001-99999kwh0.001-99999kwh
Power0-4.4KW0-22KW
Timing0.1-9990.1-999
Temperature-20~150°C-20~150°C
Frequency50-60Hz50-60Hz
Power factor0.01-1PF0.01-1PF

5.1 General Specifications

  • DIY Supplies: Electrical
  • Display Type: Digital Only
  • Accuracy Class: ±1
  • Operating Temperature: -20°C to +85°C
  • Certification: CE
  • Origin: Mainland China

6. User Tips

  • Temperature Unit: The temperature display is in Celsius (°C) only. There is no option to change it to Fahrenheit.
  • Timer Memory: The timer function has a memory feature that saves the measurement even after the power is turned off. This is useful for tracking cumulative usage.
  • Alarm Volume: The alarm sound may be quiet depending on the installation environment. Ensure you can hear it if critical.
  • Accuracy: While the display provides detailed readings, for highly precise applications, consider cross-referencing with calibrated equipment.
  • Installation: Always ensure proper wiring and insulation, especially when installing in electrical panels.

7. Troubleshooting

  • No Display/Power:
    • Check all wiring connections to ensure they are secure and correctly connected to the AC source.
    • Verify that the AC input voltage is within the specified range (50-300V).
  • Incorrect Readings:
    • For 100A models, ensure the Current Transformer (CT) is correctly installed around the Live (L) wire and its wires are properly connected to the meter.
    • Perform a factory reset (see Section 4.3) to rule out incorrect settings.
  • Alarm Not Triggering/Too Quiet:
    • Check the alarm settings (see Section 4.2) to ensure the thresholds are set appropriately.
    • The alarm sound volume is fixed and may be quiet in noisy environments. Consider visual monitoring if audible alerts are insufficient.
  • Timing/Electric Energy Not Clearing:
    • Follow the specific reset procedure for Electric Energy and Timing (see Section 4.3). Ensure you press and hold the 'Δ' button for 3 seconds until the timing flashes, then use 'M' to clear.
  • Display Difficult to Read:
    • Ensure the meter is installed in a location with adequate lighting and at an appropriate viewing angle. The full-view color screen is designed for clarity, but extreme angles or poor lighting can affect readability.

8. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the meter's display and casing. Do not use abrasive cleaners or solvents.
  • Environmental Conditions: Ensure the meter is operated within its specified operating temperature range (-20°C to +85°C) and protected from excessive moisture or direct sunlight.
  • Inspection: Periodically inspect wiring connections for any signs of wear, damage, or loose connections.

9. Warranty and Support

For warranty information and technical support, please refer to the seller's policies or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.