PEAKMETER PM85/MS85

Contents

PEAKMETER PM85/MS85 Digital Multimeter User Manual

Model: PM85/MS85

Brand: PEAKMETER

1. Introduction

The PEAKMETER PM85/MS85 is a professional 20000 Counts Digital Multimeter designed for accurate measurement of DC/AC voltage, DC/AC current, resistance, capacitance, diode, transistor (hFE), frequency, and continuity. This manual provides essential information for safe and effective use of the device.

PEAKMETER Digital Multimeter with test leads
Figure 1: PEAKMETER Digital Multimeter with test leads.
Video 1: Product demonstration showing various measurement functions and battery installation.

2. Warning & Safety Information

Please read and understand all safety information before operating this device. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Always de-energize the circuit before making resistance, capacitance, or diode measurements.
  • Do not exceed the specified measurement range for any function.
  • Avoid dropping or impacting the device, as this can damage internal components.
  • Ensure test leads are properly connected to the correct input terminals for the desired measurement.
  • This device is rated 1000V CAT III and 600V CAT IV, indicating its overvoltage protection capabilities. Always use appropriate safety precautions for the voltage levels being measured.

3. Product Features

The PM85/MS85 Digital Multimeter offers a wide range of features for various electrical testing needs:

  • Multifunctional Measurement: Capable of measuring voltage (AC/DC), current (AC/DC), resistance, capacitance, frequency, diode, transistor (hFE), and continuity.
  • Precise Digital Display: 20000 counts digital display for intuitive and accurate readings.
  • Safety Protection: Equipped with automatic overload protection.
  • Automatic Shutdown: Automatically powers off after 20 minutes of inactivity to conserve battery life.
  • Data Retention (HOLD): Allows you to freeze the displayed reading.
  • Backlight: For improved visibility in dimly lit environments.
  • Manual Range: Provides control over measurement ranges.
Multimeter overview highlighting multi-functionality
Figure 2: Multi-function overview of the digital multimeter.

4. Setup

4.1 Battery Installation

  1. Ensure the multimeter is powered off.
  2. Locate the battery compartment on the back of the device.
  3. Use a screwdriver to open the battery cover.
  4. Insert a 9V 6F22 battery, observing the correct polarity.
  5. Close the battery cover and secure it with the screw.
Battery compartment and 9V battery installation
Figure 3: Easy removal of battery cover for 9V battery installation.

4.2 Test Lead Connection

  1. Open the test lead jacks.
  2. Insert the red test lead into the 'VΩHz' or '10A MAX' terminal, depending on the measurement.
  3. Insert the black test lead into the 'COM' (Common) terminal.
Labeled diagram of the multimeter's components and functions
Figure 4: Labeled diagram of the multimeter showing input terminals and functions.
Back view of the multimeter showing test lead storage slots
Figure 5: Convenient test lead storage design on the back of the multimeter.

5. Operating Instructions

To perform a measurement:

  1. Turn the rotary switch to the desired measurement function (e.g., V~ for AC Voltage, V- for DC Voltage, Ω for Resistance, A~ for AC Current, A- for DC Current, etc.).
  2. Contact the test leads to the object under test. Ensure proper connection and polarity.
  3. Read the measurement value on the digital display.

5.1 Common Measurements

  • Voltage Measurement (AC/DC): Connect test leads in parallel to the circuit. Use V~ for AC and V- for DC.
  • Current Measurement (AC/DC): Connect test leads in series with the circuit. Ensure the circuit is de-energized before connecting. Use A~ for AC and A- for DC.
  • Resistance Measurement: De-energize the circuit. Connect test leads across the component.
  • Capacitance Measurement: De-energize and discharge the capacitor. Connect test leads across the capacitor.
  • Diode Test: De-energize the circuit. Connect test leads across the diode.
  • Continuity Test: De-energize the circuit. Connect test leads across the path to be tested. A beep indicates continuity.
  • Transistor (hFE) Test: Insert the transistor into the appropriate socket on the multimeter.
Multimeter measuring household AC voltage from an outlet
Figure 6: Household voltage measurement from an outlet.
Multimeter measuring in an electrical panel
Figure 7: High precision and fast response measurement in an electrical panel.
Demonstration of diode, battery, resistance, and capacitor measurements
Figure 8: Real shot test function display for diode, battery, resistance, and capacitor measurements.

6. Maintenance

To ensure the longevity and accuracy of your multimeter:

  • Battery Replacement: Replace the 9V battery when the low battery indicator appears on the display. Refer to Section 4.1 for instructions.
  • Cleaning: Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents.
  • Storage: Store the multimeter in a cool, dry place away from direct sunlight and extreme temperatures. If storing for extended periods, remove the battery.
  • Physical Care: Avoid dropping or subjecting the device to strong impacts.

7. Troubleshooting

If you encounter issues with your multimeter, refer to the following common problems and solutions:

  • Unit fails to power on: Check whether the 9V battery is properly installed and has sufficient charge. Replace if necessary.
  • Inaccurate display: The device may require recalibration, or the battery might be low. Replace batteries first. If the issue persists, contact support.
  • Unable to measure voltage: Verify that the correct range is selected on the rotary switch. Ensure test leads are securely connected to the 'VΩHz' and 'COM' terminals.
  • No reading for resistance/capacitance/diode: Ensure the circuit is de-energized before measurement. Check for proper test lead connection.

8. Specifications

Functional IndicatorRange (PM85/MS85)Basic Accuracy
DC Voltage200mV, 2V/20V/200V, 1000V±0.05% to ±0.15% +5
AC Voltage2V/20V/200V, 750V±0.8% to ±1% +15
Frequency20kHz±1.5% +15
Resistance200Ω, 2KΩ/20KΩ/200KΩ/2MΩ, 20MΩ, 200MΩ±0.8% to ±5.0% +10/20
Capacitance20nF/200nF/2.0uF/20uF, 200uF±4.0% to ±5.0% +2/20
DC Current2mA/200mA, 20A±0.5% to ±2.0% +10/20
Alternating Current2mA, 200mA, 20A±0.8% to ±2.5% +20/50
Diode TestYes
Continuity (Fengming on-off)Yes
Transistor (hFE)Yes
BacklightYes
Data RetentionYes
Automatic Shutdown20 Minutes
Low Voltage WarningYes
Power Supply9V 6F22 Battery
Dimensions188 x 92 x 50mm
WeightApprox. 350g (including battery)
Operating Temperature0 - 40 ℃
CertificationCE, FCC, RoHS
Technical parameter table for PM85 and MS85 models
Figure 9: Technical parameters and specifications for PM85/MS85 models.
Dimensions of the multimeter
Figure 10: Dimensions of the PEAKMETER PM85/MS85 Digital Multimeter.

9. User Tips

  • For quick continuity checks, use the audible beep function.
  • When measuring unknown voltages or currents, always start with the highest range setting and work your way down to avoid overloading the meter.
  • Always ensure the circuit is off and capacitors are discharged before measuring resistance or capacitance to prevent damage to the meter or component.
  • The 'HOLD' button is useful for capturing readings in hard-to-see areas.

10. Warranty and Support

This product comes with a one-year warranty for free repair of non-man-made defects. Please retain your purchase receipt as proof of purchase for warranty claims.

For further assistance or to access the full user manual in PDF format, please refer to the official documentation: User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.