1. Introduction
This manual provides detailed instructions for the VariCore 12.8V 200Ah LiFePO4 lithium battery. It includes basic parameters, MPPT settings, wiring, series and parallel connection guidelines, charging and discharging procedures, and applicable equipment scenarios. The battery features a built-in intelligent BMS (Battery Management System) for protection and stable discharge performance. Please read this manual carefully to ensure safe and optimal use of the product.
The VariCore 12.8V 200Ah LiFePO4 battery is designed with high-purity lithium iron phosphate materials and an intelligent BMS protection system. It is compatible with MPPT charging and offers stable discharge performance.
2. Safety Warnings and General Precautions
- Always operate with power off when connecting or disconnecting the battery.
- Ensure correct polarity (positive to positive, negative to negative). Reverse connection and short circuits are strictly prohibited and can cause severe damage to the battery, BMS, and connected equipment, posing safety hazards.
- Use appropriate wiring with a cross-sectional area of at least 10mm² for MPPT charging and 16mm² for series/parallel connections to handle 100A discharge current, preventing wire heating and safety risks.
- Install the MPPT controller in a well-ventilated area, away from fire and heat sources, maintaining a distance of at least 30cm from the battery to prevent high-temperature impact on performance.
- During charging or discharging, if the battery shows abnormal heat, bulging, liquid leakage, peculiar smell, or smoke, immediately stop use, disconnect power, and contact customer service. Do not continue using a faulty battery.
- Avoid over-discharging (below 9.5V) as it can lead to permanent battery damage and reduced capacity.
- Avoid frequent peak discharge (above 100A, or single continuous time >10 seconds) to prevent BMS and battery damage.
- Disconnect solar panel connections during rainy or thunderstorm weather to prevent lightning damage.
- When connecting batteries in series or parallel, ensure all batteries are of the same model, capacity, and batch. Mixing different types is strictly prohibited.
3. Setup and Initial Connection
Before any connection, ensure all power sources are off. Wear insulated gloves for safety.
3.1. Unboxing and Initial Inspection
Upon receiving your VariCore LiFePO4 battery, carefully inspect the packaging for any signs of damage. Remove the battery and check its appearance for any bulging, leaks, or physical damage. Verify that the wiring terminals are not oxidized or loose.
3.2. Single Battery Connection
For single battery use, connect the positive (+) terminal of your load/charger to the positive (+) terminal of the battery, and the negative (-) terminal of your load/charger to the negative (-) terminal of the battery. Ensure all connections are tight and secure.

Figure 1: Close-up of battery terminals and integrated display/ports.
3.3. Series Connection (Maximum Voltage Shall Not Exceed 80V)
Series connection increases the total voltage while keeping the capacity unchanged. This is suitable when a single 12V battery does not meet the voltage requirements of your equipment. Always use 12V 120Ah LiFePO4 batteries of the same model, capacity, and batch.
3.3.1. Wiring Method
- Power-off Preparation: Disconnect all batteries from loads and charging equipment. Ensure the BMS function of all batteries is normal. Check that the voltage difference between individual batteries is ≤0.3V.
- Battery Series Wiring: Connect the negative pole (-) of the first battery to the positive pole (+) of the second battery using an adaptive wire (cross-sectional area ≥16mm² for 100A discharge). Tighten terminals for good contact. Repeat for additional batteries (e.g., for 3 batteries, connect battery 1 (-) to battery 2 (+), and battery 2 (-) to battery 3 (+)).
- Total Output Terminals: The remaining positive pole (+) of the first battery and negative pole (-) of the last battery become the total output terminals for loads or chargers. Mark them clearly.
- Wiring Detection: Verify all wiring terminals are tightened and polarity is correct. After confirming no short circuits or looseness, measure the total output voltage (should be 12V × number of series batteries). If the voltage is abnormal, immediately cut power and troubleshoot.

Figure 2: Two Batteries In Series Diagram

Figure 3: Three Batteries In Series Diagram
3.4. Parallel Connection
Parallel connection increases the total capacity while keeping the voltage unchanged. This is ideal for applications requiring longer discharge durations. Always use 12V 120Ah LiFePO4 batteries of the same model, capacity, and batch.
3.4.1. Wiring Method
- Power-off Preparation: Disconnect all batteries from loads and charging equipment. Ensure all batteries are in a power-off state. Check that the BMS system of each battery has no fault alarm and the single battery voltage difference ≤0.3V to prevent circulating current.
- Battery Parallel Wiring: Use two adaptive wires (cross-sectional area ≥16mm²). Connect the positive (+) terminals of all batteries together (bus connection) with one wire, and the negative (-) terminals of all batteries together (bus connection) with the other wire. Tighten each wiring terminal. When wiring in parallel, connect the negative poles (-) of all batteries first, then the positive poles (+) to avoid short-circuit sparks.
- Total Output Terminals: The positive bus connection point becomes the total output positive pole (+), and the negative bus connection point becomes the total output negative pole (-).
- Wiring Detection: Verify all wiring terminals are tightened and polarity is correct. After confirming no short circuits or looseness, measure the total output voltage (should be 12V). If the voltage is normal, the parallel connection is successful; if heating or abnormal voltage occurs, cut off power immediately and troubleshoot.

Figure 4: Two Batteries In Parallel Diagram

Figure 5: Three Batteries In Parallel Diagram
4. Operating Instructions
The VariCore LiFePO4 battery is equipped with an intelligent BMS for charging and discharging protection.
4.1. Charging
The battery supports two charging methods: using a special charger or MPPT charging.
4.1.1. Method 1: Charging with a Special Charger (Basic Charging Method)
- Charger Selection: Use a 12V special charger designed for LiFePO4 lithium batteries that supports constant current and constant voltage mode. The charging current should be less than 60A (recommended >24A), and the charger output voltage must match the battery charging cut-off voltage (14.6V ±0.1V). Chargers for lead-acid batteries or non-special chargers are strictly prohibited.
- Pre-charging Check: Disconnect the battery from the load. Inspect the battery for damage, and ensure wiring terminals are not oxidized or loose. Verify the charger is fault-free and the charging wire is intact.
- Wiring Operation: Connect the positive (+) clip of the charger to the positive (+) terminal of the battery, and the negative (-) clip to the negative (-) terminal. Ensure good contact. Reverse connection is strictly prohibited.
- Start Charging: Connect the charger to the power supply. The BMS will initiate constant current charging. As the battery voltage approaches 14.6V, it switches to constant voltage charging, and the current gradually decreases. Charging is complete when the current approaches 0, and the BMS automatically cuts off the circuit.
- Completion of Charging: Disconnect the charger power supply, then disconnect the wiring between the charger and the battery.

Figure 6: VariCore 14.6V 20A LiFePO4 Battery Charger.

Figure 7: LiFePO4 Battery Charger Specifications.
4.1.2. Method 2: MPPT Charging (Suitable for Solar Energy Storage Scenarios)
After proper wiring (refer to Section 3.3 for MPPT Controller Adaptation Requirements and Wiring Method), the MPPT controller will automatically track the maximum power from the solar panel to charge the battery. The BMS system monitors the entire process to ensure charging safety. The BMS will automatically cut off the charging circuit once charging is complete.
4.1.3. Precautions for Charging
- Charge the battery in a well-ventilated area, away from direct sunlight, fire, and heat sources.
- Disconnect the power supply promptly after charging to prevent the BMS from operating unnecessarily.
- If the battery voltage is below 10V (low-power state), pre-charge it with a small current (e.g., 10A) for 2 hours until the voltage rises above 11V before normal charging.
4.2. Discharging
The maximum continuous discharge current for this battery is 100A (at 25°C). The BMS monitors discharge current, voltage, and temperature, providing protection against over-discharging, overcurrent, and high temperature.
4.2.1. Discharging Operating Steps
- Pre-discharge Check: Verify the battery voltage is normal, and check for any physical damage or loose terminals. Ensure the connected load's parameters (rated voltage 12V, maximum current ≤100A) match the battery.
- Wiring Operation: Connect the positive (+) wire of the load to the positive (+) terminal of the battery, and the negative (-) wire of the load to the negative (-) terminal. Tighten all terminals. Reverse connection is strictly prohibited. Use wires with a cross-sectional area ≥16mm² for 100A discharge.
- Post-discharge Processing: Recharge the battery within 24 hours after discharge is complete to prevent prolonged low-power states, which can lead to plate sulfation and shorten battery life.
4.2.2. Precautions for Discharging
- Do not exceed 100A continuous discharge or perform frequent peak discharges (>200A for >10 seconds) to avoid damaging the BMS and battery.
- Do not discharge below 9.5V. The BMS will automatically cut off discharge at this voltage.
- Optimal discharge temperature is 20°C to 25°C. Avoid large current discharge (>30A) below -20°C to prevent performance degradation.
5. Maintenance and Storage
5.1. Regular Inspection
Regularly inspect the battery for any physical damage, bulging, or leaks. Check wiring terminals for tightness and corrosion. For series or parallel connections, periodically check the voltage and temperature of each individual battery.
5.2. Long-Term Storage
If the battery will not be used for an extended period, fully charge it before storage. Recharge the battery every 1-2 months to prevent damage from low power. Store the battery in a cool, dry, and well-ventilated place, away from direct sunlight and extreme temperatures.
5.3. Disposal
LiFePO4 lithium batteries are recyclable and environmentally friendly. When the battery reaches the end of its life, dispose of it according to local environmental protection regulations. Do not discard it randomly. Contact local recycling facilities for proper disposal.
6. Troubleshooting
- Battery not charging/discharging: The BMS may have cut off the circuit due to overcharging, over-discharging, overcurrent, or high/low temperature. Check for abnormalities in the battery, wiring, and connected equipment. Eliminate faults before attempting to use again.
- Abnormal voltage in series/parallel connection: Immediately cut off power. Check all wiring for correct polarity, tightness, and ensure all batteries are of the same model, capacity, and batch. Replace any faulty batteries.
- Battery overheating or unusual smell: Immediately stop use, disconnect power, and contact customer service. This could indicate an internal fault.
- Battery not holding charge well: Ensure the battery is fully charged before storage and recharged periodically (every 1-2 months) if not in use. Avoid deep discharges below 9.5V.
7. Specifications
| Parameter Name | Specific Specification | Remarks |
|---|---|---|
| Rated Voltage | 12V DC | Standard working voltage, suitable for 12V system equipment |
| Rated Capacity | 200Ah (25°C, 0.2C discharge) | At room temperature, discharge to 9.5V with a 24A current, discharge duration ≥5 hours |
| Battery Type | Lithium Iron Phosphate (LiFePO4) | Safe and stable, no memory effect, long cycle life |
| Charging Method | Intelligent constant current and constant voltage charger | Supports MPPT charging, compatible with 12V MPPT controller |
| Maximum Continuous Discharge Current | 100A (25°C) | Peak discharge current ≤200A (single time ≤10 seconds, frequent peak discharge is prohibited) |
| Charging Cut-off Voltage | 14.6V ±0.1V | Automatically detected by BMS, the charging circuit is cut off when the voltage is reached |
| Discharging Cut-off Voltage | 9.5V ±0.1V | BMS automatically cuts off discharge to avoid damage caused by over-discharging |
| Cycle Life | ≥4000 times (25°C, 80% depth of charge and discharge) | The lower the depth of charge and discharge, the longer the cycle life |
| Operating Temperature Range | Charging: 0°C~55°C; Discharging: -20°C~65°C | Optimal operating temperature: 20°C~25°C with the best performance |
| Product Application Range | Automotive starting; 12V motors and motor products; 12V solar energy systems and ordinary 12V lighting, etc. | MPPT controller must support LiFePO4 lithium battery charging mode |
| Weight | 18kg (approx.) | Weight may vary according to cell batches or production batches |
| Size | 360*190*250mm | Dimensions of the battery unit |

Figure 8: Product Dimensions and Specifications.
8. Applicable Equipment and Scenarios
This 12V 120Ah LiFePO4 lithium battery is built-in with a BMS protection system and supports 100A continuous discharge, making it suitable for all DC electrical equipment with a rated voltage of 12V and a maximum working current of ≤100A. When matching equipment, confirm that the parameters are consistent to avoid over-specification use.
8.1. Energy Storage Equipment
- 12V MPPT solar energy storage systems
- Small energy storage inverters (power ≤1200W)
- 12V UPS uninterruptible power supplies
- Applicable Scenarios: Household energy storage, outdoor energy storage, off-grid power supply systems.
8.2. Mobile Power Supply Equipment
- RV power supply equipment
- Off-road vehicle auxiliary power supplies
- Ship auxiliary power supply systems
- High-power electric wheelchairs
- Portable energy storage power supplies
- Advantages: Large capacity, stable discharge, 100A large current can meet the power supply requirements of high-power mobile equipment with long endurance.
8.3. Industrial/Outdoor Equipment
- 12V DC motors (maximum current ≤100A)
- Outdoor monitoring equipment
- Emergency lighting systems
- Portable testing equipment
- Agricultural irrigation equipment
- Advantages: Resistant to high and low temperatures, wide operating temperature range, adaptable to complex outdoor and industrial environments, and BMS protection ensures stable equipment operation.
8.4. Household/Commercial Emergency Equipment
- Household small energy storage power supply
- Commercial emergency power supply
- Medical equipment (low-power 12V equipment)
- Emergency broadcast equipment
- Advantages: Safe and stable, no memory effect, can be used as a long-term backup, fast emergency power supply response to ensure normal equipment operation.

Figure 9: Usage Scenarios.

Figure 10: Outdoor Mobile Power Supply Features.

Figure 11: USB3.0 Type-C Charging Capability.
9. User Tips
- Initial Charge: Batteries often arrive partially charged (e.g., around 65%). It is recommended to fully charge the battery before its first use.
- Solar Integration: This battery integrates well with solar power stations and hybrid inverters. Ensure your MPPT controller supports LiFePO4 charging mode.
- Cell Monitoring: For demanding applications or if experiencing unexpected shutdowns, consider monitoring individual cell health within the battery pack. A faulty cell can trigger protection modes prematurely.
- Product Quality: Users generally report the product as well-made and functioning as described.
10. Frequently Asked Questions (FAQ)
- Q: What is the model number of this battery?
- A: The model number is YQ-4.
- Q: What are the dimensions of this product?
- A: The size of the battery is 360*190*250mm.
- Q: Does this battery have any certifications?
- A: Yes, it has CE certification.
- Q: Where is this battery manufactured?
- A: It is made in Mainland China.
11. Warranty and Support
The warranty period for this product is 12 months from the date of purchase. If the product experiences quality problems due to non-human factors within the warranty period, you may contact us via the consultation email for free repair or replacement services. Damage caused by human factors or failure to operate in accordance with the specifications is not covered by the warranty.
Official Website: www.varicore.cn
Consultation Email: info@varicore.cn
Shenzhen Varicore Electronic Technology Co., Ltd. reserves the final right of interpretation of this manual.
12. Product Video
Video 1: Manufacturing and assembly process of the VariCore LiFePO4 battery.
13. Additional Resources
A detailed user manual in PDF format is available for download. This PDF contains comprehensive information and diagrams for advanced users.
User Manual (PDF): View User Manual (PDF)