GlintDeer KWS-AC301

Contents

KWS-AC301 Wattmeter Power Meter User Manual

Model: KWS-AC301 | Brand: GlintDeer

1. Introduction

This manual provides essential information for the safe and effective use of your GlintDeer KWS-AC301 AC Electricity Meter. This device is designed to measure and display various electrical parameters including voltage, current, power, electrical energy, timing, frequency, power factor, and temperature. Please read all instructions carefully before operation.

KWS-AC301 Wattmeter Power Meter displaying various electrical parameters
KWS-AC301 Wattmeter Power Meter displaying voltage, current, power, energy, timing, frequency, power factor, and temperature.

2. Safety & Warnings

Read all instructions before use to ensure safety and prevent damage.

  • Do not use with incompatible devices/accessories to avoid affecting product performance or damaging related equipment.
  • If the product shows any abnormal conditions such as smoke, unusual noises, or odors, immediately stop using it.
  • This product is not food-related. Keep it away from children and avoid accidental ingestion/touching of sharp parts (if any).

3. Features

  • 8 Major Functions: Measures current, timing, electrical energy, voltage, power, temperature, power factor, and frequency.
  • Durable Construction: Made with PVC flame retardant material, featuring an all-round buckle design for stable and safer installation.
  • Clear Display: Full-view color screen for enhanced readability.
  • Accurate Measurement: Utilizes a dedicated metering chip for precise and reliable data calculation.
  • Wide Application: Suitable for various uses, promoting power saving and rational electricity usage.
KWS-AC301 display with labeled parameters: Voltage, Current, Timing, Electric Energy, Power, Power Factor, Frequency, Temperature
Labeled display parameters of the KWS-AC301.

4. Specifications

Attribute AC301-20A Model AC301-100A Model
Diversion method Built-in External
Voltage AC 50-300V
Current 0-20A 0-100A
Electric energy 0.001-99999kwh
Power 0-4.4KW 0-22KW
Timing 0.1-999
Temperature -20~150 ℃
Frequency 50-60Hz
Power factor 0.01-1PF

General Specifications:

  • Brand Name: GlintDeer
  • Model Number: KWS-AC301 AC Electricity Meter
  • Dimensions: 76.4*48*23.4mm
  • Operating Temperature: -20℃ to +85℃
  • Accuracy Class: ±1-2
  • Power Supply: AC
  • Display Type: Digital Only
  • Certification: CE
Dimensions diagram of KWS-AC301 meter and current transformers
Dimensions of the KWS-AC301 meter and its current transformers.

5. Setup & Installation

Preparation: Remove all protective films from the device before installation.

Wiring Diagrams:

Ensure power is disconnected before attempting any wiring. Incorrect wiring can cause damage to the device or electrical system.

For KWS-AC301-20A Model (Built-in Diversion):

Wiring diagram for KWS-AC301-20A model
Wiring diagram for the 20A model. Connect L and N for input AC 50-300V, and L and N for output load.

For KWS-AC301-100A Model (External Diversion):

This model uses an external current transformer (CT). There are two types of 100A CTs: 'Close' and 'Opening'.

100A-Close Current Transformer:
Wiring diagram for KWS-AC301-100A model with closed current transformer
Wiring diagram for the 100A model with a closed current transformer. The load wire passes through the CT.

Video demonstrating the 100A-Close CT installation:

100A-Opening Current Transformer:
Wiring diagram for KWS-AC301-100A model with opening current transformer
Wiring diagram for the 100A model with an opening current transformer. The load wire passes through the CT.

6. Operation

The KWS-AC301 features three buttons: Up (△), M (Menu/Mode), and Down (▽).

Diagram showing button functions for KWS-AC301: zero clearing, setting interface, factory reset
Button functions for the KWS-AC301.

Button Functions:

  • M Key (Menu/Mode):
    • Press and hold for 3 seconds: Enter settings interface.
    • Single click: Zero clearing (for Timing or Kwh).
    • Double click: Jump position (during settings).
  • Up Key (△):
    • Press and hold for 3 seconds: Zero clearing (for Timing or Kwh).
    • Single click: Increment value (during settings).
  • Down Key (▽):
    • Single click: Decrement value (during settings).

Alarm Prompt Setting:

  1. Press and hold the M key for three seconds to enter the settings interface.
  2. Double-click the M key to navigate between alarm parameters (e.g., voltage, current).
  3. Click the Up (△) or Down (▽) keys to adjust the alarm value.
  4. Once the value is set, press and hold the M key for 3 seconds to save.

The alarm prompt will appear only when the actual test value is greater than or equal to the set value. When the instrument has an alarm, it will make a sound, and the numerical unit will flash on the screen. For example, if the current alarm is set to 1.000A, an alarm will trigger if the actual current used is greater than 1.000A.

To turn off the alarm prompt: Set the alarm value higher than the actual value, or set all alarm values to 0.

Alarm setting instructions with visual cues and alarm sound hole
Visual guide for alarm setting and indication of alarm sound hole.

Electric Energy and Timing Reset:

  1. Press and hold the Up (△) key for 3 seconds until the timing display flashes.
  2. Click the M key to clear the timing.
  3. Double-click the M key to switch to the electrical energy display.
  4. Click the M key again to clear the electrical energy.

Restoring Factory Settings:

Press and hold the Down (▽) key, then turn on the power. When you hear a sound from the meter, it indicates that the restoration is successful. The factory default voltage alarm value is 275V; all other values are 0.

7. User Tips

  • The meter can be integrated into extension cords for convenient monitoring.
  • Users report good accuracy and low error tolerance for measurements.
  • The device is practical and easy to use for various electrical measurements.
  • Note that the meter may not measure accurately from 0V.

8. Troubleshooting

  • No Display/Power: Check power connections. Ensure the AC input voltage is within the 50-300V range.
  • Incorrect Readings: Verify all wiring connections are secure and correct according to the diagrams for your specific model (20A or 100A). For 100A models, ensure the load wire passes correctly through the current transformer.
  • Alarm Constantly Triggering: Review your alarm settings. Adjust the alarm threshold to a value appropriate for your application, or set it to 0 to disable.
  • Display Freezing/Unresponsive: Try performing a factory reset (see Operation section). If the issue persists, disconnect power, wait a few minutes, and reconnect.
  • Temperature Sensor Not Working: Ensure the temperature sensor is properly connected to the device.

9. Maintenance

  • Keep the device clean and free from dust and moisture. Use a soft, dry cloth for cleaning.
  • Avoid exposing the device to extreme temperatures or direct sunlight for prolonged periods.
  • Do not attempt to open or repair the device yourself, as this will void the warranty and may pose a safety risk.

10. Warranty & Support

This product is manufactured in China. For technical support or warranty inquiries, please contact your retailer or the manufacturer directly using the information below:

  • Manufacturer Country: China
  • Manufacturer Telephone: +86-13417026232
  • Manufacturer Email: xinhui0518@163.com
  • Responsible Person: Ouyanghui
  • EU Representative: eVatmaster Consulting GmbH
  • EU Representative Address: Bettinastr. 30, 60325 Frankfurt am Main, Germany
  • EU Representative Email: contact@evatmaster.com
  • EU Representative Telephone: +49-6995179070

Please retain your proof of purchase for warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.