EARUELETRIC SSR-DA/AA/DD Series

Contents

EARUELETRIC Solid State Relay Module Instruction Manual

Models: SSR-DA, SSR-AA, SSR-DD Series (10A to 100A)

1. Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of your EARUELETRIC Solid State Relay (SSR) Module. These high-power, protective, and sealed SSRs are designed for various applications, including PID temperature control. Please read this manual thoroughly before use.

Three types of EARUELETRIC Solid State Relays: AC Control AC, DC Control AC, and DC Control DC, with current ratings from 10A to 100A.
Figure 1: Overview of EARUELETRIC SSR Module Types
Video 1: Product demonstration of the EARUELETRIC Solid State Relay Module.

2. Safety Information

Always observe the following safety precautions:

  • Ensure all power is disconnected before installation or maintenance.
  • Wiring should be performed by qualified personnel in accordance with local electrical codes.
  • Do not exceed the specified voltage and current ratings of the SSR.
  • Proper heat dissipation is crucial for reliable operation. Use an appropriate heat sink, especially for higher current models.
  • Avoid touching terminals when power is applied.
  • The SSR is a non-contact switching device; however, treat it with the same caution as mechanical relays.

3. Product Overview and Features

The EARUELETRIC Solid State Relay Module utilizes an optical coupler for fast, stable, and isolated operation between the control and load sides. It is constructed from flame-retardant material and features high-strength, rustproof screws for durability.

Key Features:

  • Optical Coupler: Ensures fast switching speed and stable operation of core components.
  • Flame-Retardant Material: Made of excellent high-temperature flame-retardant material, sturdy and durable.
  • High Strength Screws: Made of high tenacity rustproof material, preventing easy breakage and wire slippage.
  • Zinc Heat Sink: Facilitates fast heat dissipation to prevent overheating and ensure stable operation.
  • High Isolation Voltage: Provides protection for electrical safety.
  • Stabilized Trigger Current: Achieved through an infrared light-emitting diode.
  • Safe and Secure: Offers stable and safe performance.
Diagram showing key features of the SSR module including Optical Coupler, Flame-Retardant Material, High Strength Screws, and Zinc Heat Sink.
Figure 2: Key Features of the SSR Module
Detailed view of an SSR-40 DA module with labels for Load Voltage (24-380VAC), Product Model (DA: DC Control AC), LED Working Indicator, Control Voltage (3-32VDC), and Wiring Terminal.
Figure 3: SSR-40 DA Component Labels

4. Specifications

The SSR modules are available in various current ratings and control types. Refer to the tables below for detailed specifications.

General Product Parameters:

Table of product parameters including Product Name: Solid State Relay, Product Model: SSR-DA/AA/DD, Rated Current: 10A-100A (Optional), Starting Current: 5mA, On-State Pressure Drop: ≤1.5V, On-Off Time: ≤10MS, Insulation Voltage: ≥2500VAC, Insulation Resistance: 1000MΩ/500VDC, Working Temperature: -25°C-75°C, Certification: CE. Also includes dimensions: 60mm/2.36in height, 45mm/1.77in width, 23mm/0.906in depth.
Figure 4: Product Parameters and Dimensions

Detailed Specifications by Model Type:

Detailed specification tables for DC Control AC, AC Control AC, and DC Control DC SSR models. Each table lists Model, Load Current, Control Voltage, Load Voltage Range, Cooling Condition, Shut-off Voltage, Starting Current, Insulation Voltage, On-Off Time, Work Instructions, On-state leakage current, On-state pressure drop, Insulation Resistance, and Ambient Temperature.
Figure 5: Detailed Specifications for SSR-DA, SSR-AA, and SSR-DD

5. Installation and Wiring

Proper installation and wiring are critical for the safe and efficient operation of your SSR module. Ensure all power is off before proceeding.

Wiring Terminal Identification:

  • Terminals 1 & 2: Load terminals (connect to the device being controlled).
  • Terminals 3 & 4: Input/Control terminals (connect to the control signal source).

Wiring Diagrams:

DC Control AC (SSR-DA Series)

Controls an AC load using a DC control signal.

Wiring diagram for DC Control AC SSR. Input terminals 3 and 4 connect to a DC Power Supply (3-32VDC). Load terminals 1 and 2 connect to an AC Power Supply (24-380VAC) and a Heating Rod. Red wire represents Live, Blue represents Zero Line. Leakage is ≤5mA after power-on.
Figure 6: DC Control AC Physical Wiring Diagram

AC Control AC (SSR-AA Series)

Controls an AC load using an AC control signal.

Wiring diagram for AC Control AC SSR. Input terminals 3 and 4 connect to an AC Power Supply (80-250VAC). Load terminals 1 and 2 connect to an AC Power Supply (24-380VAC) and a Heating Rod. Red wire represents Live, Blue represents Zero Line. Leakage is ≤5mA after power-on.
Figure 7: AC Control AC Physical Wiring Diagram

DC Control DC (SSR-DD Series)

Controls a DC load using a DC control signal.

Wiring diagram for DC Control DC SSR. Input terminals 3 and 4 connect to a DC Power Supply (3-32VDC). Load terminals 1 and 2 connect to a DC Power Supply (12-220VDC) and a Heating Rod. Red wire represents positive electrode '+', Blue represents negative electrode '-'. Leakage is ≤5mA after power-on.
Figure 8: DC Control DC Physical Wiring Diagram

Heat Sink Installation:

For all SSR models, especially those with higher current ratings (e.g., 40A and above), a heat sink is essential to prevent overheating and ensure longevity. Mount the SSR firmly to a suitable heat sink using thermal paste for optimal heat transfer.

6. Operation

Once correctly wired and powered, the SSR operates by receiving a control signal at its input terminals (3 & 4). When the control signal is applied, the internal optical coupler activates, allowing current to flow through the load terminals (1 & 2), thereby switching the connected load ON. When the control signal is removed, the load switches OFF.

  • LED Working Indicator: Most models include an LED indicator that illuminates when the control signal is active, providing visual confirmation of the SSR's state.
  • No Contact, No Spark: As a solid-state device, the SSR operates without mechanical contacts, resulting in silent operation and no electrical arcing or sparks, which enhances safety and extends lifespan compared to traditional mechanical relays.
Image highlighting the 'No Contact No Spark Quieter Super Isolation' feature of the SSR, explaining it works internally without mechanical contact and offers fast and sensitive optocoupler operating response.
Figure 9: Benefits of Solid State Operation

7. Load Power Selection Reference

When selecting an SSR, it's important to consider the type of load (resistive or inductive) and its current/power requirements. Inductive loads typically require a higher current rating for the SSR due to inrush currents.

Table showing recommended Resistive Use Current, Resistive Load (W), Inductive Use Current, and Inductive Load (W) for SSR models from 10A to 100A. For example, a 10A SSR can handle 5A resistive use (1000W) or 1.5A inductive use (350W).
Figure 10: Load Power Selection Reference Table
  • Resistive Load: Converts electricity to heat through resistance, used in heating, voltage division, and testing.
  • Inductive Load: Operates via magnetic energy storage, primarily used in motors, transformers, and power grid systems.

8. Maintenance

Solid State Relays are generally maintenance-free due to their lack of moving parts. However, periodic checks are recommended:

  • Visual Inspection: Regularly check for any signs of physical damage, loose connections, or discoloration due to overheating.
  • Cleanliness: Keep the SSR and its heat sink free from dust and debris to ensure proper heat dissipation.
  • Connection Integrity: Periodically verify that all wiring connections are secure.

9. Troubleshooting

If your SSR module is not functioning as expected, consider the following:

  • No Output/Load Not Switching:
    • Check if the control signal is correctly applied to terminals 3 and 4.
    • Verify the control voltage is within the specified range (e.g., 3-32VDC for DA/DD, 80-250VAC for AA).
    • Ensure the load voltage is present and within the specified range (e.g., 24-380VAC for DA/AA, 12-220VDC for DD).
    • Confirm the load current does not exceed the SSR's rated capacity.
    • Check for any blown fuses or tripped circuit breakers in the load circuit.
  • SSR Overheating:
    • Ensure a proper heat sink is installed and securely attached with thermal paste.
    • Verify that the ambient temperature is within the operating range (-25°C to 75°C).
    • Confirm the load current is not exceeding the SSR's rating, especially for inductive loads which require derating.
    • Ensure adequate ventilation around the SSR and heat sink.
  • Unexpected Leakage Current:

    After power-on, there might be a small leakage current (typically ≤5mA) at the output terminal even when the SSR is off. This is normal for some SSR designs. If this leakage interferes with sensitive loads, consider adding a snubber circuit or a small dummy load.

10. User Tips

  • Frequency Compatibility: The AC control and AC load SSR models (SSR-AA and SSR-DA) are designed to work with standard AC frequencies, typically 50/60Hz.
  • DC-DC SSR Voltage Limits: For DC-DC SSRs (SSR-DD), always adhere strictly to the specified load voltage range (e.g., 12-220VDC). Exceeding this voltage, even if the current is low, can damage the unit. The limit is primarily voltage-based, but power (voltage x current) must also be considered to prevent overheating.
  • Heat Sink for All Models: Even for lower current models, using a heat sink is a good practice to prolong the life of the SSR, especially if it will be operating continuously or in higher ambient temperatures.

11. Warranty and Support

For any issues or questions not covered in this manual, please contact your supplier or the manufacturer's customer support. Keep your purchase records for warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.