1. Introduction
This product utilizes a single-chip microcomputer control system combined with a high-precision temperature measuring probe, offering superior temperature control performance and accuracy compared to similar products. The XH-W1411 features a three-window design for real-time display of start and stop values. It includes functions such as intermittent work, scheduled boot, and scheduled shutdown. This versatile controller can be widely used in various applications including greenhouses, aquatic animal husbandry, aquaculture, and general room temperature control, making it a valuable tool for home and professional use.
2. Safety & Warnings
- Read all instructions carefully before using this product. Failure to follow these instructions may result in damage to the product or personal injury.
- Warning: Keep the device and its cord out of reach of children under 3 years old.
- Keep away from children unless supervised by an adult.
- Do not use this product for purposes other than its intended use.
- Inspect the product before each use; do not use if damaged.
- Follow all installation and operation guidelines to avoid injury.
- This is an electrical product. Do not expose it to water or moisture. The thermostat host is not waterproof; avoid water. It is forbidden to use in bathrooms or outdoors.
- This product uses a three-prong plug; ensure you use a grounded socket.
- Do not use power greater than the product's nominal power, as this can cause permanent damage and danger.
- During actual temperature control, always observe whether the temperature control is executing correctly before leaving the device unattended.
3. Specifications
| Parameter | Value |
|---|---|
| Product Name | High Precision Digital Temperature Controller |
| Model | XH-W1411 |
| Temperature Measurement Range | -55°C to +120°C |
| Temperature Measuring Accuracy | ±0.3°C |
| Resolution | 0.1°C |
| Temperature Control Range | -19°C to 99°C |
| Control Accuracy | 1°C |
| Temperature Measuring Probe | NTC10K/B3950 standard 1 meter waterproof probe |
| Power Supply Voltage | AC 220V (also available in DC 12V variant) |
| Display Colors | Red, Green, Blue, Yellow (optional) |
| Applicable Environment | -25°C to 55°C, 20% - 20% moisture (non-condensing) |
| Output Type | 10A Relay Output |
| Appearance Size | 90 mm * 60 mm |
| Hole Size | 70 mm * 50 mm |
| Cable Length | 1m |
| Measure Type | K |
| Screw | M12*1.5 |
| Theory | Temperature Controller |
| Display Type | DIGITAL |
| Power Type | Charger |
| Certification | CE |
| Origin | Mainland China |
| Style | Embedded |
| Is Smart Device | No |
| Use | Indoor |
| Display Size | 1.9 Inches & Under |
4. Setup
Before operating your XH-W1411 Temperature Controller, follow these steps for proper installation:
- Power Connection: Plug the product into a standard household socket. The display screen should illuminate and show the current temperature, indicating that the power supply is correctly connected.
- Probe Placement: Place the temperature probe in the specific area where you need to monitor and control the temperature.
- Set Temperatures: Set your desired start and stop temperatures using the control buttons (refer to Section 5: Operating Instructions).
- Connect Equipment: Plug the power supply of your heating or cooling equipment into the thermostat's output outlet. This will enable the thermostat to control the connected device based on your set parameters.
4.1. Components Overview

4.2. Wiring Diagram
Ensure correct wiring based on your power supply (DC 12V or AC 220V) and load requirements. Refer to the diagram below for detailed connections.

5. Operating Instructions
The XH-W1411 offers various modes and settings for precise temperature control.

5.1. Basic Temperature Control
After power-on, if the current temperature is within the set range, the output will immediately activate. It will then deactivate when the temperature reaches the set stop value.
- Heating Mode (Start Temperature < Stop Temperature):
Example: To control water boiling, you want it to stop heating at 60°C and restart heating if the temperature drops to 45°C. Set the start value to 45 and the stop value to 60. - Refrigeration Mode (Start Temperature > Stop Temperature):
Example: In summer, to control a greenhouse, you want a fan to start when the temperature exceeds 35°C and stop when it cools down to 32°C. Set the start value to 35 and the stop value to 32.
5.2. SET Button Functions
The SET button serves multiple purposes:
- Power On/Off:
- To Power Off: While the device is powered on, long press the SET button for 3 seconds. The device will turn off and remain off even after power cycling.
- To Power On: While the device is powered off, press the SET button once. The device will turn on and remain on even after power cycling. - Function Selection:
In the normal temperature control state, press the SET button once to cycle through the different function modes: F-1, F-2, and F-3.
5.3. Advanced Function Modes
- F-1 Intermittent Work Mode:
This mode allows for cyclical operation. The left display shows the 'start minute' (duration of operation), and the right display shows the 'stop minute' (duration of pause). - F-2 Time Switch (Scheduled Boot):
This mode allows you to schedule when the device should turn on. The left display shows the 'hour', and the right display shows the 'minute'. The maximum setting is 99 hours and 59 minutes. - F-3 Time Switch (Scheduled Shutdown):
This mode allows you to schedule when the device should turn off. The left display shows the 'hour', and the right display shows the 'minute'. The maximum setting is 99 hours and 59 minutes.
5.4. Temperature Correction
If you notice a deviation between the displayed temperature and the actual temperature, you can calibrate the device:
- Remove the controller plug from the power source.
- Press and hold the SET button while re-supplying power to the controller. The screen will display "–00--".
- You can now adjust the temperature correction value (increase or decrease). The maximum adjustment range is -9.9 to +99.
- The real-time temperature displayed will be calculated as:
Real-time temperature = (Temperature before correction) + (Corrected value).
5.5. Self-Check Function
To enter the self-check function, press the (Start + -) buttons simultaneously while powering on the device.
5.6. Restore Factory Settings
If you encounter setting mistakes or disorder, you can restore the device to its default factory settings:
- Press the (Stop + -) buttons simultaneously while powering on the device.
- The screen will display "88-888-88", and a long buzz will sound, indicating that the restoration is complete.
Default Factory Values:
- Start Value: 25
- Stop Value: 40
- F-1 (Intermittent Work): 01-10
- F-2 (Scheduled Boot): 00-30
- F-3 (Scheduled Shutdown): 00-30
- Correction: 000
6. Maintenance
- Keep Dry: As the thermostat host is not waterproof, always keep it dry and away from any sources of moisture. Avoid using it in humid environments like bathrooms or outdoors.
- Regular Inspection: Before each use, visually inspect the product for any signs of damage to the casing, wires, or probe. Do not use if any damage is found.
- Proper Ventilation: If the controller is installed in an enclosed space, ensure adequate ventilation to prevent overheating of the unit and connected equipment.
- Cleaning: Use a soft, dry cloth to clean the display and casing. Do not use abrasive cleaners or solvents.
7. Troubleshooting
If you encounter issues with your XH-W1411, refer to the following troubleshooting guide:
- No Reaction, Screen Not Bright:
- Check if the household socket has power by plugging in another electrical device.
- If power is present, check if the thermostat was manually shut down. Press the SET button once to power it on. - Screen Displays, But No Temperature Control Function:
- If the temperature is set correctly but the connected equipment does not start or stop as expected, it's possible there's an error in the set start and stop values. Review and adjust them. - Temperature Overshoots/Undershoots (Temperature Changes Control):
- The controller's red light indicates 'start' and the green light indicates 'stop'. If these indicators are correct but the temperature still overshoots or undershoots the target, the thermostat is likely functioning correctly. The issue might be with the efficiency of your heating/cooling equipment. Consider reducing its power or adjusting its settings. - Temperature Measurement Deviation:
- If the thermostat displays a temperature that deviates from the actual temperature (e.g., thermostat shows 29.6°C when it's actually 30°C), use the temperature correction function (refer to Section 5.4). You can adjust the correction value to match the actual temperature. - Other Faults:
- For any other issues not covered in this guide, please contact the manufacturer or your supplier for assistance.
8. User Tips
- Check Package Contents: Upon receiving your XH-W1411, verify all components are present. Note that some variants or bundles may not include an external case, requiring a separate purchase or custom enclosure for protection.
- Initial Setup: Take your time during the initial setup of start and stop temperatures. Incorrect settings are a common cause of unexpected behavior.
- Wiring Double-Check: Always double-check your wiring against the provided diagram (Figure 2) to ensure safety and proper functionality, especially when dealing with AC voltages.
9. Warranty & Support
9.1. Manufacturer Information
- Manufacturer: Shenzhen Hangyue Trading Co., Ltd
- Address: No. 8, Qiaoxin South Road 2nd Street, Simapu Town, Chaonan District, Shantou City, Guangdong Province, China
- E-mail: 3145108347@qq.com
9.2. EU Authorized Representative
- Representative: ZHEKAN GmbH
- Address: Romeracker 8, 76297 Stutensee, Germany
- E-mail: eken190228@gmail.com
9.3. Importer Information
- Importer: Shenzhen Hangyue Trading Co., Ltd
- Address: No. 8, Qiaoxin South Road 2nd Street, Simapu Town, Chaonan District, Shantou City, Guangdong Province, China
9.4. Compliance
This product is CE certified, indicating compliance with European health, safety, and environmental protection standards.
9.5. Additional Resources
For a more detailed and comprehensive guide, please refer to the official user manual (PDF) available at: XH-W1411 User Manual (PDF)