1. Introduction

This user manual provides detailed instructions for the Wishcolor TV160 7th Generation Motherboard Converter Kit and the ZT-C1 Digital Multimeter. The TV160 is a versatile display test tool designed for Vbyone and LVDS signals, capable of converting them to HDMI output and featuring a built-in 7-inch display. The ZT-C1 is a compact digital multimeter for various electrical measurements. This kit is ideal for technicians and enthusiasts working with display panels and electronics.

Wishcolor TV160 Motherboard Converter Kit and ZT-C1 Digital Multimeter with accessories
Figure 1: Wishcolor TV160 Motherboard Converter Kit and ZT-C1 Digital Multimeter with included accessories.

2. Safety Information

  • Read all instructions carefully before use.
  • Ensure proper power supply connections to avoid damage to the device or connected components. The TV160 supports 5V-12V adapter (recommended 5-6V / 2A or more).
  • The TV160 features an integrated interface protection circuit to prevent damage from incorrect screen power supply to LVDS input pins. However, always double-check connections.
  • For the ZT-C1 Multimeter, ensure batteries are correctly installed (2x AAA 1.5V, not included).
  • Do not attempt to measure voltages or currents exceeding the multimeter's specified limits (e.g., 550V high voltage protection, 10A max current).
  • Avoid operating the devices in wet or extremely humid environments.
  • Keep out of reach of children.

3. Package Contents

The complete package includes:

  • 1 x TV160 Motherboard Converter Kit
  • 1 x ZT-C1 Digital Multimeter
  • Various adapter boards for LVDS and V-by-One connections
  • Power adapter for TV160
  • Test leads for ZT-C1 Multimeter
  • Connecting cables (e.g., FFC cables)

Note: 2pcs AAA 1.5V batteries for the multimeter are not included.

4. TV160 Motherboard Converter Kit

4.1. Overview and Features

The TV160 7th Generation Motherboard Converter is housed in a durable aluminum alloy shell, making it portable and highly compatible with various display testing scenarios. It features an integrated interface protection circuit for enhanced safety.

  • Equipped with a 7-inch high-definition (1024*600) display for direct image viewing.
  • Outputs 1080P / 60Hz HDMI-compatible signal for external display or TV connection.
  • Supports 2K TV products with single and double line 60Hz, 120Hz, 240Hz resolution LVDS signals.
  • Supports 4K TV products V-by-One (including 4, 8, 16) signal conversion into full-screen output.
  • Automatic recognition of LVDS and V-by-One signals.
  • Cycle switching between LVDS (2K mode) and V-by-One (4K mode) via dedicated buttons.
  • Wide power input: 5V-12V adapter (recommended 5-6V / 2A or more).
  • Supports 8bit / 10bit VASA, JEIDA, and other LVDS signal formats.
  • Compatible with 60Hz, 120Hz, 240Hz single-screen and dual-screen line LVDS signals.
  • Supports 4, 8, 16 V-by-One (30/60/120Hz) signals.
Front view of the TV160 Motherboard Converter with 7-inch display and control buttons
Figure 2: Front view of the TV160 Motherboard Converter, showing the 7-inch display, LVDS and Vbyone inputs, and control buttons (Power, 4K Mode, 2K Mode, Reset).
Side view of the TV160 Motherboard Converter showing HDMI output and DC power input
Figure 3: Side view of the TV160 Motherboard Converter, highlighting the HDMI output port and DC power input jack.

4.2. Setup and Connections

  1. Power Connection: Connect the provided power adapter to the DC power input jack on the TV160 (refer to Figure 3). Ensure the power adapter meets the recommended 5-6V / 2A or more current specification.
  2. Display Panel Connection:
    • Identify the appropriate adapter board for your display panel's LVDS or V-by-One interface. The kit includes various adapter boards (see Figure 4).
    • Carefully connect the adapter board to the corresponding LVDS or Vbyone input port on the TV160.
    • Connect the display panel's FFC cable to the adapter board. Ensure correct orientation and secure connection.
  3. External Display (Optional): If you wish to view the output on a larger screen, connect an HDMI cable from the TV160's HDMI output port to an external monitor or TV.
  4. Power On: Press the Power button on the TV160 to turn on the device.
Various adapter boards for LVDS and V-by-One connections included in the kit
Figure 4: Selection of adapter boards for connecting different LVDS and V-by-One display panels to the TV160 converter.

4.3. Operation

  1. Automatic Signal Recognition: The TV160 will automatically detect the connected LVDS or V-by-One signal.
  2. Mode Switching:
    • Use the "4K Mode" button to switch to V-by-One (4K mode) for 4K TV products.
    • Use the "2K Mode" button to switch to LVDS (2K mode) for 2K TV products.
    • The device cycles through modes with each press.
  3. Reset: If the display is not showing correctly or you need to restart the signal detection, press the "RES" (Reset) button.
  4. Display Output: The image will be displayed on the built-in 7-inch screen and simultaneously outputted via the HDMI port (if an external display is connected).

5. ZT-C1 Digital Multimeter

5.1. Overview and Features

The ZT-C1 is a compact and reliable digital multimeter designed for various electrical measurements. It features automatic ranging and a clear backlight display.

  • Automatic range selection.
  • 4000 counts true RMS measurement.
  • 550V high voltage protection (except current file).
  • Backlight display for easy reading in various lighting conditions.
  • Anti-break bracket for convenient positioning.
  • Data retention function.
  • Automatic shutdown to conserve battery life.
  • 10A current measurement capability.
  • 14 measurement functions (gear modes).
Front view of the ZT-C1 Digital Multimeter
Figure 5: Front view of the ZT-C1 Digital Multimeter, showing the display, rotary switch, and input jacks.

5.2. Setup (Battery Installation)

The ZT-C1 Digital Multimeter requires two (2) AAA 1.5V batteries (not included) for operation.

  1. Locate the battery compartment on the back of the multimeter (refer to Figure 6).
  2. Open the battery compartment cover.
  3. Insert two AAA 1.5V batteries, ensuring correct polarity (+/-).
  4. Close the battery compartment cover securely.
Back view of the ZT-C1 Digital Multimeter showing the battery compartment
Figure 6: Back view of the ZT-C1 Digital Multimeter, showing the kickstand and battery compartment.

5.3. Basic Operation

  1. Power On/Off: Rotate the central dial to the desired measurement function to turn on the multimeter. Rotate to "OFF" to power off.
  2. Function Selection: Use the rotary switch to select the desired measurement function (e.g., DC Voltage, AC Voltage, Resistance, Frequency, Diode, NCV, Continuity).
  3. Connect Test Leads: Insert the red test lead into the "VΩHz" jack and the black test lead into the "COM" jack for most measurements. For current measurements, use the "10A" or "mA" jacks as appropriate.
  4. Measurement: Apply the test leads to the circuit or component to be measured. The reading will appear on the display.
  5. Data Hold: Press the "HOLD" button to freeze the current reading on the display. Press again to release.
  6. Backlight: Press the backlight button (often combined with HOLD or a separate button) to activate the display backlight.

6. Specifications

6.1. TV160 Motherboard Converter

FeatureSpecification
Display7-inch HD (1024*600)
HDMI Output1080P / 60Hz
LVDS Signal Support2K TV products, single/double line 60Hz, 120Hz, 240Hz resolution; 8bit/10bit VASA, JEIDA formats
V-by-One Signal Support4K TV products (4, 8, 16 lanes); 30/60/120Hz
Power Input5V-12V DC (recommended 5-6V / 2A+)
Shell MaterialAluminum Alloy

6.2. ZT-C1 Digital Multimeter

Electrical Specifications

Table of Electrical Specifications for the ZT-C1 Digital Multimeter, covering DC/AC Voltage and Current
Figure 7: ZT-C1 Digital Multimeter Electrical Specifications (Voltage and Current).
Table of Electrical Specifications for the ZT-C1 Digital Multimeter, covering Resistance, Frequency, Diode, NCV, and Continuity
Figure 8: ZT-C1 Digital Multimeter Electrical Specifications (Resistance, Frequency, Diode, NCV, Continuity).

General and Environmental Specifications

Table of General and Environmental Specifications for the ZT-C1 Digital Multimeter
Figure 9: ZT-C1 Digital Multimeter General and Environmental Specifications.
FeatureSpecification
Display4000 counts LCD
RangingAuto
MaterialABS/PVC
Update Rate3 times/second
True RMSYes
Data HoldYes
Backlight/FlashlightYes
Low Electric Quantity AlertYes
Auto Power OffYes
Dimensions120 x 60 x 30mm (4.7 x 2.4 x 1.2")
Operating Temperature0~40°C
Operating Humidity<75%
Storage Temperature-20~60°C
Storage Humidity<80%

7. Maintenance

  • Keep both devices clean and dry. Wipe with a soft, damp cloth if necessary. Do not use abrasive cleaners or solvents.
  • For the ZT-C1 Multimeter, replace batteries when the low battery alert appears. Remove batteries if the device will not be used for an extended period to prevent leakage.
  • Store the devices in a cool, dry place away from direct sunlight and extreme temperatures.
  • Handle adapter boards and FFC cables with care to prevent damage to connectors.

8. Troubleshooting

TV160: No image on display / External monitor:
  • Ensure the power adapter is correctly connected and providing sufficient power (5-6V / 2A+ recommended).
  • Verify that the display panel's FFC cable is securely and correctly connected to the appropriate adapter board.
  • Check that the adapter board is properly seated in the TV160's input port.
  • Press the "RES" (Reset) button to re-initialize signal detection.
  • Confirm the correct mode (2K/4K) is selected for your display panel type.
  • If using an external display, ensure the HDMI cable is connected correctly and the external display is set to the correct input source.
ZT-C1: Multimeter not turning on / erratic readings:
  • Check if the batteries are installed correctly and have sufficient charge. Replace if necessary.
  • Ensure the rotary switch is set to a valid measurement function, not "OFF".
  • Verify that the test leads are properly inserted into the correct input jacks.
  • Clean the test lead tips and input jacks if there is any dirt or corrosion.
  • Ensure the measurement range is appropriate for the value being measured (though ZT-C1 has auto-ranging, extreme values might require manual adjustment if available, or indicate an issue).

9. User Tips

  • When connecting display panels to the TV160, always double-check the FFC cable orientation and the compatibility of the adapter board to prevent damage.
  • For the ZT-C1 Multimeter, utilize the data hold function when taking readings in hard-to-see areas.
  • The TV160's built-in screen is excellent for quick checks, but for detailed analysis or larger viewing, connect it to an external HDMI monitor.
  • Keep the various adapter boards organized and labeled to quickly find the correct one for different display types.

10. Warranty and Support

For detailed warranty information and technical support, please refer to the official product documentation or contact Wishcolor customer service.

A comprehensive user manual in PDF format is available for download. Please refer to the following link for the official PDF manual: Official User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.