1. Introduction
The RICHMETERS RM113D NCV Digital Multimeter is a versatile and reliable tool designed for measuring various electrical parameters. It can accurately measure voltage (AC/DC), current (AC/DC), resistance, capacitance, frequency, and temperature. This device features stable performance, high precision, high reliability, clear readings, and built-in overload protection. Its large, high-contrast display with full symbol indication ensures clear visibility, even in challenging conditions.
2. Safety Information
Please read and understand all safety instructions before using the multimeter. Failure to follow these instructions may result in electric shock, fire, or damage to the device.
- Always ensure the multimeter is in the correct measurement mode and range before connecting to a circuit.
- Do not exceed the maximum input values specified for each function.
- Exercise extreme caution when working with live circuits.
- Inspect the test leads for damage before each use. Do not use if insulation is compromised.
- Do not operate the multimeter if it appears damaged or is not functioning properly.
- Keep hands and fingers behind the probe barriers during measurements.
- Replace batteries promptly when the low battery indicator appears to ensure accurate readings.
3. Package Contents
Verify that all items listed below are present in your package:
- 1 x RICHMETERS RM113D Multimeter
- 1 x English User Manual
- 1 pair x Electronic Test Probes (Red and Black)
- 1 x Thermocouple (Max 400 degrees Celsius)
4. Product Overview
Familiarize yourself with the components of your RM113D Digital Multimeter:



5. Setup
5.1 Battery Installation
The RM113D Multimeter requires 3 AAA batteries (not included) for operation.
- Locate the battery compartment cover on the back of the multimeter.
- Use a screwdriver to remove the screw securing the battery cover.
- Open the battery cover.
- Insert 3 AAA batteries, ensuring correct polarity (+ and -).
- Replace the battery cover and secure it with the screw.
6. Operating Instructions
The RM113D operates in Manual Range mode. Use the Function Knob to select the desired measurement function.
6.1 Basic Measurements
- Voltage Measurement (AC/DC):
Turn the Function Knob to the 'V~' (AC Voltage) or 'V=' (DC Voltage) position. Connect the test leads to the circuit in parallel. The display will show the voltage reading. - Current Measurement (AC/DC):
Turn the Function Knob to the 'A~' (AC Current) or 'A=' (DC Current) position. Connect the test leads in series with the circuit. Ensure the correct input terminal (10A or mA) is used based on the expected current. - Resistance Measurement (Ω):
Turn the Function Knob to the 'Ω' position. Connect the test leads across the component to measure its resistance. Ensure the circuit is de-energized before measuring resistance. - Capacitance Measurement (F):
Turn the Function Knob to the 'F' position. Connect the test leads across the capacitor. Ensure the capacitor is discharged before measurement. - Frequency Measurement (Hz):
Turn the Function Knob to the 'Hz' position. Connect the test leads to the signal source. - Temperature Measurement (°C/°F):
Turn the Function Knob to the '°C/°F' position. Connect the thermocouple to the appropriate input terminals. The display will show the temperature.
6.2 Special Functions
- NCV (Non-Contact Voltage) Detection:
Turn the Function Knob to the 'NCV' position. Bring the NCV sensor at the top of the multimeter close to a live AC voltage source. The device will beep and the NCV indicator will light up if AC voltage is detected. - Data Hold:
Press the 'HOLD' button to freeze the current reading on the display. Press it again to release. - Backlight:
Press the backlight key (often indicated by a light bulb icon) to turn the display backlight on or off. This is useful for measurements in dark environments. - Flashlight:
The multimeter includes a flashlight function for convenient measurement in the dark. Activate it using the dedicated button or by holding the backlight button (refer to specific model instructions if different). - Auto Power Off:
The multimeter will automatically turn off after several minutes of inactivity to conserve battery life.
7. Maintenance
- Cleaning: Use a soft, damp cloth to clean the multimeter casing. Do not use abrasive cleaners or solvents.
- Storage: Store the multimeter in a dry, cool place away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.
- Calibration: For professional accuracy, periodic calibration by a qualified technician is recommended.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No display or dim display | Low batteries or incorrect battery installation. | Replace batteries with new ones, ensuring correct polarity. |
| Incorrect readings | Incorrect function/range selection, damaged test leads, or external interference. | Verify function/range. Check test leads for continuity. Move away from strong electromagnetic fields. |