1. Introduction
The XY6020L is a versatile CNC adjustable direct current stabilized voltage power supply, designed for applications requiring precise control over voltage and current. It features a constant voltage and constant current design, offering an output voltage range of 0.0-60.00V, an output current of 0.0-20.00A, and a maximum output power of 1200W. This device is available as a complete unit (XY-6020L) or as a base plate for integration into custom systems (XY-6020L base plate).
The full-view LCD screen provides comprehensive data display and simple operation, ensuring stable working performance. It supports the standard MODBUS protocol for serial communication, allowing for remote control and integration into automated systems. The device also incorporates multiple protection mechanisms to ensure safe and reliable operation.
2. Safety Information
- Always ensure the input voltage is within the specified range (6.0-70V) to prevent damage to the device.
- Do not exceed the maximum output current (20.00A) or power (1200W).
- Ensure proper ventilation around the device, especially for the base plate, to allow the intelligent temperature-controlled fan and large heat sink to function effectively.
- Avoid short-circuiting the output terminals.
- Disconnect power before making any wiring changes or performing maintenance.
- This device is intended for DC power supply. Do not connect to AC power supply directly.
- Keep the device away from moisture and extreme temperatures.
3. Product Overview
The XY6020L is a high-performance power supply module designed for precision applications. It features a robust base plate with a large heat sink and an intelligent temperature-controlled fan for efficient cooling.

Figure 1: XY6020L Power Supply Module and Display Unit
Key Components:
- Display Unit: Full-view LCD screen for displaying voltage, current, power, capacity, energy, and time. Features an encoder button for navigation and adjustment, and a SW button for switching displays.
- Base Plate: Contains the main power conversion circuitry, input/output terminals, and control interfaces.
- Input Terminals (VIN+/VIN-): For connecting the DC input power source (6.0-70V).
- Output Terminals (OUT+/OUT-): For connecting the load.
- Power Supply Switch (OFF/ON): Hard switch for powering the device on/off.
- DIP Switch: Used to set fixed output voltages (5V, 9V, 12V, 24V, 36V, 48V, 60V) when the base plate is used independently.
- 10K NTC External Temperature Sensor Port: For connecting an external temperature sensor.
- Serial Port Communication Port: For connecting a TTL to 485 module or WiFi module for remote control.
- Display Connection: Connects the display unit to the base plate.
- Key Press Connection: Connects the control buttons from the display unit to the base plate.
- WiFi Module (Optional): Allows for mobile APP and web control.

Figure 2: Labeled Components of the XY6020L Base Plate
4. Specifications
| Parameter | Value |
|---|---|
| Product Name | NC DC Regulated Power Supply |
| Product Model | XY6020L |
| Input Voltage | 6.0-70V |
| Output Voltage | 0.0-60V |
| Input Current | 0-20.00A |
| Output Ripple Typical Value | 100mv VPP |
| Output Power | 0-1200W |
| Maximum Output Voltage | (Input voltage ÷ 1.1) - 2 |
| Input Voltage Measurement Resolution | 0.01V |
| Output Voltage Setting & Measurement Resolution | 0.01V |
| Current Setting Resolution | 0.01A |
| Input Voltage Measurement Accuracy | ±1% + 5 words |
| Output Voltage Setting & Measurement Accuracy | ±0.4% + 1 word |
| Output Current Setting & Measurement Accuracy | ±0.5% + 3 words |
| Cooling Fan Activation (ON) | Current > 2A, Power > 50W, Temperature > 50℃ |
| Cooling Fan Deactivation (OFF) | Current < 1.5A, Power < 45W, Temperature < 45℃ |
| External Temperature Protection | 0-110℃ (default off) |
| Input Overvoltage Protection | 71V (default) |
| Input Undervoltage Protection | 4.8-71V (adjustable, default 4.8V) |
| Output Overvoltage Protection | 65V (default) |
| Output Overcurrent Protection | 0-22A (adjustable, default 22A) |
| Output Over Power Protection | 1250W (default) |
| Over Temperature Protection | 60-110℃ (default 95℃) |
| Timeout Protection | 0-100H (adjustable, default off) |
| Over Capacity Protection | 0-9999AH (adjustable, default off) |
| Super Energy Protection | 0-9999WH (adjustable, default off) |
| XY-6020L Size (Display Unit) | 79 x 43 x 27mm |
| XY-6020L Base Plate Size | 72 x 109 x 42mm |
| XY-6020L Weight (Display Unit) | 180g |
| XY-6020L Base Plate Weight | 230g |

Figure 3: Detailed Product Parameters
5. Setup
5.1 Wiring Connections
Carefully connect the input power source and the load to the respective terminals on the base plate. Ensure correct polarity (VIN+ to positive, VIN- to negative, OUT+ to positive load, OUT- to negative load).

Figure 4: Wiring Connections for the Base Plate and Display
5.2 DIP Switch Settings (for Base Plate only)
If using the base plate independently for a fixed output voltage, configure the DIP switches according to the desired voltage. The 'NC' setting is for numerical control when using the dial head to adjust pressure.

Figure 5: DIP Switch Configuration Table
5.3 Physical Installation
Refer to the provided dimensions for proper enclosure design and mounting. Ensure adequate space for ventilation, especially around the heat sink.

Figure 6: Dimensions and Suggested Opening Size
6. Operating Instructions
6.1 Setting Voltage and Current
- In the operation interface, press the
V/Abutton to enter the setting voltage and current interface. - The LCD downlink display
SET,CVflashes, indicating voltage selection. - Press
SWor rotate the encoder to switch voltage selection. - Adjust the set voltage through the rotary encoder.
- Press
V/Aagain, the LCD downlink displayCCflashes, indicating current bit selection. - Press
SWor rotate the encoder to switch current bit selection. - Adjust the set current through the rotary encoder.
- Press the
V/Abutton again to exit and save the settings to return to the operating interface. - Alternatively, long press the
V/Abutton for 2 seconds or wait for 6 seconds without any key operation. The system will automatically exit and save the settings, and return to the operation interface.

Figure 7: Setting Voltage and Current
6.2 Quick Setting of Voltage or Current
In the parameter setting interface, set parameter FEt to CV or CC. Rotate the encoder in the operation interface to quickly set the voltage or current.
6.3 Parameter Setting Screen
Press and hold the SW button for 2 seconds to enter the parameter setting screen. Here you can configure various protection limits and device behaviors.

Figure 8: Parameter Setting Screen
6.4 Input and Output Voltage Display
Press the SW button on the running interface to switch between displaying the input voltage and the output voltage.

Figure 9: Input and Output Voltage Display
6.5 Viewing Power, Capacity, Energy, and Time
In the operation interface, short press the encoder button to switch the display of power (W), capacity (Ah), energy (Wh), and time (h).

Figure 10: Viewing Power, Capacity, Energy, and Time
6.6 Locking Function
In the operation interface, long press the encoder button for 2 seconds to lock the voltage and current settings, preventing accidental misoperation. Long press the encoder button for 2 seconds again to unlock.

Figure 11: Locking Function
6.7 Data Group Function
This product has 10 sets of data (Cd0 to Cd9), with Cd8=12V and Cd=24V being non-adjustable. Data is saved in Cd0 by default. To check and modify:
- Long press the
V/Akey for 2 seconds to enter the data group call out interface. The upper two lines display the set voltage value (CV) and set current value (CC) of the data group. The downstream display group number is CD1-CD9. - Press the
V/Akey to switch between setting voltage CV, setting current CC, and data set serial number Cd. Modify parameter values through the encoder. - After confirming the data group, long press the
V/Akey to pull out the data group and return to the operation interface.

Figure 12: Data Group Function
6.8 Other Functions (Capacity/Energy/Running Time Statistics)
After the power is turned ON, statistics will automatically start. If the power is turned OFF, the previous state will be displayed. If the power is turned ON again, the record will automatically restart. To clear the corresponding data, press and hold the ON/OFF button for 2 seconds.
Setting Maximum Capacity (OAH)/Maximum Energy (OPH): When the OAH/OPH function is started and the statistical capacity/energy is higher than the set maximum, the power supply automatically shuts down and flashes "OAH" / "OPH". After the alarm is removed, the capacity/energy statistics will be cleared automatically.
Setting the Maximum Discharge Time (OHP): If the OHP function is enabled, when the running time of the power supply is greater than the set maximum discharge time, the power output will be automatically turned off and "OHP" will blink. After the OHP alarm is lifted, the time statistics will be cleared automatically.
This function allows for quantitative/timed power supply control.

Figure 13: Capacity/Energy/Running Time Statistics
7. Protection Mechanisms
The XY6020L incorporates several protection features to ensure safe operation:
- External Temperature Protection (ETP): 0-110℃ (default off).
- Input Overvoltage Protection (OVP): Default 71V.
- Input Undervoltage Protection (LUP): Adjustable from 4.8-71V, default 4.8V.
- Output Overvoltage Protection (OVP): Default 65V.
- Output Overcurrent Protection (OCP): Adjustable from 0-22A, default 22A.
- Output Over Power Protection (OPP): Default 1250W.
- Over Temperature Protection (OTP): Adjustable from 60-110℃, default 95℃.
- Timeout Protection (OHP): Adjustable from 0-100H, default off.
- Over Capacity Protection (OAH): Adjustable from 0-9999AH, default off.
- Super Energy Protection (OPH): Adjustable from 0-9999WH, default off.
8. WiFi Connection (Optional)
The XY6020L supports remote control via a WiFi module, allowing control through a mobile application or web interface. This requires an optional WiFi module.

Figure 14: WiFi Module for Remote Control
To connect the WiFi module:
- Ensure the WiFi module is correctly connected to the serial port communication port on the base plate.
- Power off the equipment and then turn on the power.
- Press and hold the pairing button on the WiFi module for 5 seconds. The indicator light should flash four times with an interval of 1 second.
- Press and hold the pairing button for 5 seconds again to confirm the flash of the indication point.
- Open the Sinilink app on your mobile device.
- Select 'Compatibility mode (AP mode)' for WiFi module manual connection.
- Follow the in-app instructions to connect to the device's hotspot (e.g., "Sinilinkproduct" network) and enter the provided password (e.g., 12345678).
- Once connected, return to the app to complete the device setup and begin remote control.
Video 1: Demonstration of WiFi Connection and App Control
9. User Tips
- This power supply can be used as a bench power supply for various electronic projects.
- The output voltage can be set as low as 0.0V, allowing for precise low-voltage applications, including 3.6V.
- When connecting to a battery, ensure the battery voltage does not exceed the input voltage limits of the XY6020L to prevent damage. The device has input overvoltage protection (default 71V) and input undervoltage protection (adjustable 4.8-71V).
- For fixed voltage outputs using the base plate, remember to set the DIP switches correctly. The 'NC' setting is crucial when using numerical control.
- Utilize the 10 data groups to save frequently used voltage and current settings for quick recall.
10. Troubleshooting
- No Power/Display: Check input power connections and ensure the power supply switch is in the 'ON' position. Verify the display connection cable is securely attached.
- Output Not Stable: Ensure the input power source is stable and capable of supplying the required current. Check for loose connections.
- Overload Protection Triggered: Reduce the load or increase the set current/power limits in the parameter settings. Check for short circuits in the load.
- Over Temperature Protection Triggered: Ensure adequate ventilation around the device. Check if the cooling fan is operating correctly when conditions (current, power, temperature) exceed thresholds.
- WiFi Connection Issues: Ensure the WiFi module is correctly installed and powered. Verify that the indicator light flashes as described in the setup. Double-check WiFi network name and password in the app. Ensure your mobile device is connected to the "Sinilinkproduct" hotspot during the pairing process.
- Incorrect Voltage/Current Readings: Verify the accuracy settings in the parameters. If persistent, contact support.
11. Maintenance
- Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
- Regularly check all wiring connections for tightness and signs of wear or damage.
- Ensure the cooling fan is free from obstructions and operating efficiently.
- Store the device in a dry, cool environment when not in use.
- Avoid exposing the device to strong electromagnetic fields.
12. Warranty and Support
This product comes with a 1-year guarantee. If your purchase does not meet merchantable quality, fitness for purpose, or match the description, please contact the seller for assistance. For any technical support or inquiries, refer to the seller's contact information provided at the time of purchase.