GEYA GYR9NM-RCBO Type A

Contents

GEYA GYR9NM Type A RCBO Instruction Manual

Residual Current Circuit Breaker with Over Current Protection

GEYA GYR9NM Type A 2-Pole RCBO

1. Product Overview

The GEYA GYR9NM Series RCBO (Residual Current Circuit Breaker with Over-current Protection) is designed for use in AC 50Hz or 60Hz lines, with a rated voltage of 240V and rated current up to 40A. This device provides essential safety functions including leakage protection, overload protection, and short circuit protection.

When personal contact occurs or the leakage current of the power grid exceeds the specified value, the RCBO is engineered to cut off the fault current within 0.1 seconds, thereby protecting personal safety and preventing equipment failure due to leakage. It also safeguards against overloads and short circuits in the protected line.

The RCBO can also serve as a means for infrequent breaking and switching of lines under normal operating conditions, primarily utilized in building lighting and power distribution systems.

GEYA GYR9NM RCBOs with fault indication explanation

Figure 1: GEYA GYR9NM RCBOs (2-Pole and 4-Pole) with fault indication details. The text on the image indicates: "1. If all handles are on OFF position, means exist residual current! 2. If only the left handle on OFF position, means MCB failure!"

2. Specifications

General Characteristics:

  • Brand Name: GEYA
  • Model Number: GYR9NM-RCBO Type A
  • Product Name: Type A RCBO Electro-mechanical
  • Type: Residual Current, RCD
  • Certification: CE
  • Standard: IEC61009-1
  • Is Smart Device: No
  • Does it include wireless functionality?: No
  • Does it include a Battery?: No
  • High-concerned chemical: none
  • Origin: Mainland China

Electrical Data:

CharacteristicValue
Rated Voltage (Ue):AC230V (220V)
Rated Frequency:50/60Hz
Poles:2-Pole (1P+N), 4-Pole
Rated Current (In):1A, 6A, 10A, 16A, 20A, 25A, 32A, 40A
Rated Sensitivity (IΔn):30mA (0.03A), 100mA (0.1A), 300mA (0.3A)
Breaking Capacity:6000A
Rated Insulation Voltage (Ui):500V
Rated Impulse Withstand Voltage (Uimp):4kV
Rated Residual Making and Breaking Capacity (IΔm):500A
Rated Residual Connecting and Breaking Capacity (IΔc):6kA
Rated Residual Non-Operating Current:0.5IΔn
Break Time (Residual current IΔ=IΔn):0.1s
Break Time (Residual current IΔ=2IΔn):0.08s
Break Time (Residual current IΔ=5IΔn):0.04s

Mechanical & Environmental Data:

CharacteristicValue
Mechanical Life / Electric Life:4000 cycles
Protection Class (Direct Install):Ip20
Protection Class (In Distribution Box):Ip40
Ambient Temperature:-25°C to +40°C
Storage Temperature:-25°C to +60°C

Wiring & Connection:

Wire TypeWiring Size
Copper/Hard Wire:1-25mm²
Cord/Hoop Terminals:1-16mm²
  • Connection: Top and bottom (ELM), Top line (ELE)
  • Mounting: Din Rail
  • Contact Status Indication: Yes
  • Fault Indication: Yes
  • Circuit Identification: Yes

Dimensions:

Dimensions of GEYA GYR9NM 2-Pole RCBODimensions of GEYA GYR9NM 4-Pole RCBO

Figure 2: Dimensions (in mm) for 2-Pole (left) and 4-Pole (right) GEYA GYR9NM RCBOs.

Characteristics Curves & Temperature Compensation:

Characteristics Curve B and C for RCBOs and Temperature Compensation Table

Figure 3: Trip characteristics curves (Type B and Type C) and temperature correction coefficients for GEYA GYR9NM RCBOs. The table shows current correction coefficients for ambient temperatures from -20°C to 60°C, with 30°C as the benchmark (coefficient 1.00).

3. Installation and Setup

Installation of the GEYA GYR9NM RCBO should only be performed by a qualified electrician in accordance with local electrical codes and regulations.

Mounting:

  • The RCBO is designed for Din Rail mounting. Ensure the Din Rail is securely installed within the distribution box or enclosure.
  • Snap the RCBO onto the Din Rail, ensuring it is firmly seated.

Wiring:

Refer to the wiring diagram below for correct connections. Ensure all connections are tight and secure to prevent loose contacts and overheating.

Wiring diagram for GEYA GYR9NM 2-Pole and 4-Pole RCBOs

Figure 4: Wiring diagram for 2-Pole (left) and 4-Pole (right) GEYA GYR9NM RCBOs.

  • Input/Output Terminals: Connect the incoming power supply to the top terminals and the load to the bottom terminals.
  • Neutral Connection: For 2-Pole (1P+N) and 4-Pole devices, ensure the neutral wire is correctly connected as indicated on the device (typically marked 'N').
  • Wire Sizes: Use appropriate wire sizes as per the specifications:
    • Copper/Hard Wire: 1-25mm²
    • Cord/Hoop Terminals: 1-16mm²
  • Poles: Select the correct RCBO model (2-Pole or 4-Pole) based on your circuit requirements.

Warning: Incorrect wiring can lead to electric shock, fire, or damage to the device and connected equipment. Always consult a qualified electrician.

4. Operation

Switching On/Off:

  • To switch the circuit ON, push the operating handle(s) upwards to the 'ON' position.
  • To switch the circuit OFF, push the operating handle(s) downwards to the 'OFF' position.

Fault Indication:

The RCBO provides visual indication of different fault conditions:

  • Residual Current (Earth Leakage) Trip: If all operating handles are in the 'OFF' position after a trip, it indicates that a residual current (earth leakage) fault has occurred.
  • Overload/Short Circuit Trip (MCB Failure): If only the left operating handle (for multi-pole devices) is in the 'OFF' position after a trip, it may indicate an overload or short circuit in the protected circuit, or potentially an internal MCB failure within the RCBO.

Test Function:

A test button (typically marked 'T' or 'Test Monthly') is located on the front of the RCBO. This button is used to verify the residual current protection function of the device.

  • Press the test button firmly. The RCBO should trip immediately (handles move to 'OFF' position).
  • If the RCBO does not trip, the residual current protection function may be faulty, and the device should be replaced immediately.
  • Reset the RCBO by pushing the handle(s) back to the 'ON' position after testing.

5. Maintenance

The GEYA GYR9NM RCBO is designed for reliable operation with minimal maintenance. However, regular checks are essential to ensure continued safety and performance.

  • Monthly Test: It is crucial to press the test button at least once a month to ensure the residual current protection mechanism is functioning correctly. Follow the steps outlined in the "Test Function" section above.
  • Visual Inspection: Periodically inspect the RCBO for any signs of physical damage, discoloration, loose connections, or overheating. Any such signs warrant immediate attention from a qualified electrician.
  • Cleaning: Keep the device clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use abrasive cleaners or solvents.
  • Environmental Conditions: Ensure the operating and storage temperatures remain within the specified ranges (-25°C to +40°C for operation, -25°C to +60°C for storage) to prevent degradation of performance or damage.

Warning: Do not attempt to repair a faulty RCBO. Always replace it with a new, equivalent device. Disconnect power before any inspection or cleaning.

6. Troubleshooting

If your GEYA GYR9NM RCBO trips or fails to operate as expected, consider the following common issues and solutions:

  • RCBO Trips (All Handles OFF):
    • Symptom: The RCBO trips, and all operating handles are in the 'OFF' position.
    • Cause: This indicates a residual current (earth leakage) fault in the protected circuit.
    • Solution: Disconnect all loads from the circuit. Try to reset the RCBO. If it holds, reconnect loads one by one to identify the faulty appliance or section of wiring. If it trips immediately without any load, the fault is likely in the fixed wiring. Consult a qualified electrician to locate and rectify the leakage fault.
  • RCBO Trips (Only Left Handle OFF for Multi-Pole):
    • Symptom: For 2-Pole or 4-Pole RCBOs, only the left operating handle is in the 'OFF' position after a trip.
    • Cause: This typically indicates an overload or short circuit in the protected circuit, or potentially an internal MCB failure within the RCBO.
    • Solution: Check for overloaded circuits (too many appliances on one circuit) or short circuits (damaged wiring, faulty appliances). Disconnect loads and try to reset. If it trips again, or if the left handle consistently trips without an apparent overload/short circuit, the RCBO itself might be faulty and requires replacement by a qualified electrician.
  • RCBO Does Not Reset:
    • Symptom: The RCBO cannot be reset to the 'ON' position after a trip.
    • Cause: A persistent fault (leakage, overload, or short circuit) is still present in the circuit, or the device itself is damaged.
    • Solution: Ensure all loads are disconnected and check for any visible faults. If the RCBO still cannot be reset, it may be damaged and needs replacement.
  • RCBO Does Not Trip When Test Button is Pressed:
    • Symptom: Pressing the test button does not cause the RCBO to trip.
    • Cause: The residual current protection mechanism is faulty.
    • Solution: The RCBO is not providing earth leakage protection and must be replaced immediately by a qualified electrician.

7. User Tips

  • Quality Assurance: Users have consistently praised the GEYA GYR9NM RCBO for its robust construction, good materials, and reliable performance in differential protection.
  • Space-Saving Design: The compact design of this RCBO is noted for providing comprehensive cable protection while saving space in distribution boards.
  • Professional Installation: Always ensure installation is carried out by a qualified electrician to guarantee correct wiring and adherence to safety standards.
  • Application Suitability: For specific applications like electric vehicle chargers, consult a qualified electrician to ensure the selected RCBO's current rating and type (e.g., Type A) are appropriate for the load and local regulations.
  • Regular Testing: Make the monthly test button press a routine to confirm the device's earth leakage protection is active.

8. Warranty and Support

GEYA products are manufactured to high standards and are backed by a commitment to quality. For specific warranty details, please refer to your purchase documentation or contact GEYA customer support directly.

In case of technical inquiries, support, or warranty claims, please contact GEYA through the following channels:

  • Website: www.geya.net
  • Email: cassie@cngeya.com
  • Phone: +86 13968799499
  • Address: Wenzhou Bridge Industrial Zone, Beibaixiang Town, Wenzhou City, Zhejiang Province
GEYA Business Card with Contact Information

Figure 5: GEYA Contact Information.

9. About GEYA

Zhejiang GEYA Electric Co., Ltd. was founded in February 2007 and is located in Wenzhou, China. It is a technology-based private enterprise that integrates research and development, production, sales, and service. GEYA focuses on the independent research and development of low-voltage electrical appliances and automation control products.

Since its establishment, GEYA Electric has always adhered to the development concept of quality first and continuous innovation, maintaining high standards and producing high-quality products. The company has obtained multiple national patents and established the GEYA brand in many countries worldwide.

GEYA products are certified to required industry standards, with approvals including CE, CB, SAA, SEMKO, TUV, EN, and more.

Video: GEYA Company Introduction and Manufacturing Process.

GEYA Company Overview with Certifications

Figure 6: GEYA Company Overview and Certifications.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.