1. Introduction
The M6013 V2 is an auto-ranging capacitor capacitance meter designed for precise measurement of capacitance and Equivalent Series Resistance (ESR). Featuring a 128x64 dot matrix LCD, it provides a 5-digit reading, making it suitable for both DIY enthusiasts and professional engineers. This manual provides essential information for the safe and effective use of your device.
2. Package Contents
Please check the package for the following items:
- 1 x M6013 Capacitance Meter
- 2 x Test Clips (Red and Black)
- 1 x User Manual

3. Setup
3.1 Battery Installation
- Locate the battery compartment on the back of the device.
- Open the battery compartment cover.
- Insert two (2) AA 1.5V batteries, ensuring correct polarity.
- Close the battery compartment cover securely.

3.2 Connecting Test Clips
- Connect the red test clip to the red input jack on the meter.
- Connect the black test clip to the black input jack on the meter.

3.3 External Power (Optional)
The device can be powered externally using a 5V micro USB cable. Connect the micro USB cable to the port on the side of the meter.

4. Operating Instructions
4.1 Power On/Off
Press the red power button to turn the device on or off.
4.2 Zeroing the Device
Before taking measurements, especially for small capacitance values, it is crucial to zero the device. With the test clips open (not touching anything), press the 'ZERO' button. This compensates for any residual capacitance in the test leads.
4.3 Measuring Capacitance and ESR
- Ensure the device is powered on and zeroed.
- Connect the test clips to the capacitor you wish to measure.
- The device will automatically detect the range and display the capacitance value (in pF, nF, uF, or mF) and ESR (Equivalent Series Resistance) on the 128x64 dot matrix LCD.
- The M6013 features an auto-ranging function and an auto-running averaging function for stable and accurate readings, particularly for picofarad (pF) values.
- Measurement of a 2200uF capacitor typically takes approximately 0.2 seconds.

4.4 Mode/Range Selection
The 'MODE RANGE' button allows for manual selection of measurement ranges if desired, though the auto-ranging feature is generally sufficient for most applications.
5. Maintenance
5.1 Cleaning
Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these may damage the casing or display.
5.2 Battery Replacement
When the battery indicator shows low power, replace the AA batteries as described in Section 3.1. Remove batteries if the device will not be used for an extended period to prevent leakage.
5.3 Storage
Store the meter in a cool, dry place away from direct sunlight and extreme temperatures. Keep it away from dust and moisture.
6. Troubleshooting
6.1 Inaccurate Readings
- Ensure the device has been properly zeroed before measurement.
- Check that the test clips are securely connected to both the meter and the component.
- Verify that the component being tested is not charged. Discharge capacitors before testing.
- Replace batteries if they are low.
6.2 Device Not Powering On
- Check battery installation and ensure batteries are fresh.
- If using external power, ensure the micro USB cable is connected correctly and the power source is active.
6.3 No ESR Reading
The M6013 is designed to measure ESR directly. If you are not getting an ESR reading, ensure the capacitor is properly connected and within the device's measurement range. The device provides direct ESR values, eliminating the need for external equivalence tables.
7. Specifications
| Parameter | Value |
|---|---|
| Display | 128*64 Dot Matrix LCD, 5-digit reading |
| Capacitance Range | 0.01pF to 470mF (470000uF) |
| Accuracy (0.01pF to 47.000nF) | 1% + 2 Digit |
| Accuracy (47.00nF to 47.000uF) | 1% + 1 Digit |
| Accuracy (47.00uF to 470.00mF) | 1% to 3% + 1 Digit |
| Refresh Time (Manual Mode) | ~0.2s to 30s (depends on capacitance value) |
| Measuring Voltage | <0.8V |
| Clamping Voltage | ~1.25V (open voltage) |
| External Power | 5V micro USB |
| Operating Current | 0.02A |
| Battery | 2 x AA 1.5V Battery (not included) |
| Battery Life Time | >80 Hours |
| Item Size | Approx 14.5 x 8 x 3cm / 5.7 x 3.1 x 1.2in |
| Item Weight | Approx 138.3g / 4.9oz |
| Package Size | Approx 17 x 9 x 5cm / 6.7 x 3.5 x 2.0in |
| Package Weight | Approx 216g / 7.6oz |
8. User Tips
- Accurate ESR Measurement: The M6013 directly measures the Equivalent Series Resistance (ESR) of capacitors. This eliminates the need for external ESR equivalence tables, providing a direct and reliable reading for capacitor health assessment.
- Stable Readings: For very small capacitance values (pF range), the device's auto-running averaging function helps to provide more stable and accurate readings. Allow a moment for the reading to stabilize.
- Zero Before Use: Always perform a 'ZERO' calibration with the test leads open before taking critical measurements to ensure the highest accuracy.
- Discharge Capacitors: For safety and accurate readings, always ensure capacitors are fully discharged before connecting them to the meter.
9. Warranty & Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.