1. Introduction

The NOYAFA JMS15 is a versatile desktop device designed for real-time monitoring of temperature and humidity. It features a clear LCD screen, perpetual calendar, and an alarm clock function, making it an essential tool for maintaining a comfortable and healthy environment in various settings such as homes, offices, hotels, and restaurants.

Key features include:

  • Real-time temperature and humidity display
  • Perpetual calendar and time display
  • Alarm clock function
  • Memory for maximum and minimum temperature/humidity values
  • Switchable Celsius/Fahrenheit units
  • Comfort level indicator (smiley/frowning face)
NOYAFA JMS15 Temperature and Humidity Detector showing current readings
The NOYAFA JMS15 display showing temperature, humidity, time, and date.

2. Setup

2.1. Battery Installation

The device operates on AAA batteries. To install or replace batteries:

  1. Locate the battery compartment on the back of the device.
  2. Open the battery compartment cover.
  3. Insert AAA batteries, ensuring correct polarity (+/-).
  4. Close the battery compartment cover securely.

2.2. Initial Placement

For accurate readings, place the device in a well-ventilated area, away from direct heat sources, direct sunlight, or drafts. The device can be placed on a desktop using its collapsible support or mounted on a wall using the wall-mount hole.

Back view of NOYAFA JMS15 showing battery compartment, wall-mount hole, and collapsible support
Back analysis of the JMS15, highlighting the battery compartment, wall-mount hole, and collapsible support.

The device features induction holes on both sides of the back to ensure wider air contact, leading to more sensitive sensors and accurate data.

Back of NOYAFA JMS15 showing induction holes for air circulation
Induction holes on the back for accurate data collection.

3. Operating Instructions

3.1. Temperature Unit Switching

Short press the C°/F button to switch the temperature display between Celsius (°C) and Fahrenheit (°F) units.

3.2. Viewing MAX and MIN Temperature and Humidity

To view the recorded maximum and minimum values:

  1. Long press the MEM button. The interface will display "MAX" to indicate the maximum recorded temperature and humidity.
  2. Short press MEM again. The interface will display "MIN" to indicate the minimum recorded temperature and humidity.
  3. Short press MEM once more to return to the normal display mode.

3.3. Date and Time Adjustment

To adjust the date and time:

  1. Long press the MODE button to enter the date and time adjustment mode. The current value being modified will flash.
  2. Short press MODE repeatedly to cycle through the adjustable parameters: minutes, hours, 24 or 12-hour format, year, month, and date.
  3. Use the ADJ button to modify the flashing value.
  4. After all adjustments are complete, short press MODE to return to the main interface.

3.4. Alarm Function On/Off

To activate or deactivate the alarm:

  1. From the main interface, short press the MODE button to enter the alarm clock mode.
  2. Short press the ADJ button to toggle the alarm clock on or off. When the alarm is on, an alarm clock icon will be displayed on the screen.
  3. If the alarm is sounding, short press the MODE button to turn off the alarm tone.
  4. After toggling the alarm, short press the MODE button to return to the main interface.

3.5. Alarm Time Adjustment

To set the alarm time:

  1. From the main interface, short press the MODE button to enter the alarm clock mode.
  2. Long press the MODE button again to enter the alarm time adjustment. The minutes will flash.
  3. Use the ADJ button to adjust the minutes.
  4. Short press MODE to switch to adjusting the hours. Use the ADJ button to adjust the hours.
  5. After completing the adjustment, short press MODE to return to the main interface.
NOYAFA JMS15 display features including time, comfort reminder, date, alarm, and humidity memory
Overview of the JMS15 display features.
NOYAFA JMS15 showing comfort level indicators based on humidity
Intelligent comfort reminder: Happy face for 40-70% humidity, sad face for <40% or >70%.

4. Maintenance

To ensure the longevity and accuracy of your NOYAFA JMS15 detector:

  • Keep the device clean and dry.
  • Avoid exposing it to extreme temperatures, direct sunlight, or high humidity for prolonged periods.
  • Use a soft, dry cloth for cleaning the display and casing.
  • Do not use abrasive cleaners, solvents, or chemical agents, as these may damage the device.
  • Store the device in a cool, dry place when not in use for extended periods.

5. Troubleshooting

  • No Display / Device Not Turning On:
    Ensure batteries are correctly installed with the proper polarity. Replace with fresh AAA batteries if necessary.
  • Incorrect Temperature/Humidity Readings:
    Verify the device is placed in a stable environment, away from direct heat sources, cold drafts, or areas with rapid temperature/humidity changes. Allow some time for the sensor to stabilize after moving the device.
  • "HH" or "LL" on Temperature Display:
    "HH" indicates the measured temperature is above the maximum range (50°C). "LL" indicates the measured temperature is below the minimum range (-20°C). Move the device to an environment within the specified operating temperature range.
  • Alarm Not Sounding:
    Check if the alarm function is enabled (alarm icon visible on display). Ensure the alarm time is set correctly.

6. Specifications

ParameterValue
Model No.JMS15
Product Size85mm x 85mm x 24mm
Battery TypeAAA battery
Temperature Measurement Range-20°C to 50°C (HH for >50°C, LL for <-20°C)
Temperature Measurement Accuracy±4°C
Humidity Measurement Range20% to 90%
Humidity Measurement Accuracy±8%
Operating Temperature-20°C to 50°C
Storage Temperature-10°C to 50°C
Operating Humidity10% to 90% (non-condensing)
NOYAFA JMS15 product information with detailed specifications and dimensions
Detailed product specifications and dimensions for the JMS15.

7. User Tips

No specific user tips were available from external reviews or Q&A for this product.

8. Warranty and Support

For warranty information or technical support, please contact your retailer or the manufacturer directly. It is recommended to keep your purchase receipt as proof of purchase.

Related Documents - JMS15

Preview 6000counts Mini Pen Multimeter User's Manual - Noyafa
Comprehensive user manual for the Noyafa 6000counts Mini Pen Multimeter, detailing features, operation, safety precautions, and technical specifications for accurate electrical measurements.
Preview Noyafa NF-514 Building Electronic Thermometer User Manual
User manual for the Noyafa NF-514 Building Electronic Thermometer. Provides detailed information on features, technical specifications, usage instructions, and maintenance for construction temperature measurement.
Preview Noyafa NF-8508: Instrukcja Obsługi Testera Okablowania LCD, Miernika Mocy Optycznej i VFL
Kompleksowa instrukcja obsługi testera okablowania Noyafa NF-8508, zawierająca szczegółowe informacje o funkcjach takich jak pomiar mocy optycznej, VFL, test PoE, lokalizacja kabli, ciągłość, długość i wiele więcej.
Preview Noyafa NF-825TMR Circuit Breaker Finder and Socket Tester User Manual
Comprehensive user manual for the Noyafa NF-825TMR, a circuit breaker finder and socket tester. Learn about its features, operation, and safety precautions for electrical testing.
Preview NOYAFA NF-513S Multifunction Measuring Instrument User Manual
Comprehensive user manual for the NOYAFA NF-513S, a multifunction measuring instrument featuring laser distance measurement, wall detection (metal, wood, AC power), and digital level functions. Includes safety warnings, operation guidance, and troubleshooting.
Preview NOYAFA NF-513S Multifunction Measuring Instrument User Manual
Comprehensive user manual for the NOYAFA NF-513S Multifunction Measuring Instrument. Learn to use its advanced wall detection capabilities for metal, wood, and AC power lines, alongside its precise laser distance meter functions. Includes safety guidelines, operational modes, product specifications, and troubleshooting.