VXSCAN V4 (SO665)

Contents

VXSCAN V4 Automotive Smoke Leak Detector User Manual

Model: V4 (SO665)

Brand: VXSCAN

1. Introduction

The VXSCAN V4 Automotive Smoke Leak Detector is a professional diagnostic tool designed for efficiently testing leaks in various vehicle pipe systems. This device is versatile and can be used across a wide range of vehicles, including cars, motorcycles, snowmobiles, ATVs, and light trucks.

With the VXSCAN V4, technicians and enthusiasts can easily identify leaks in critical automotive systems such as car sealing, throttle shafts, engine blocks, turbo systems, crankcase systems, intake systems, exhaust systems, fuel tank systems, EVAP systems, EGR systems, cooling systems, and various pipe fittings.

The V4 model introduces several enhancements over its predecessor, the VXSCAN V3, including a digital pressure gauge for more precise readings and adjustable output pressure for greater control during testing. It also includes specialized EVAP system adapters and disassembly tools for comprehensive diagnostics.

2. Key Features

  • Compact and Portable Design: Features a hook for convenient storage and portability in any workshop environment.
  • Built-in Air Pump: Lightweight design with an integrated air pump, eliminating the need for external air sources.
  • Instant Smoke Generation: No warm-up time required, allowing for immediate use.
  • Over-heat Protection: Equipped with LED indication for safety and device longevity.
  • Smart Working Cycle: A 5-minute working cycle is sufficient for most vehicle diagnoses, with the option to stop or restart at any time.
  • Adjustable Output Pressure: The inbuilt air compressor allows for output pressure adjustment between 0.3psi and 17psi.
  • Safe Smoke Generation: Utilizes a patented solution to produce dense, healthy, safe, and harmless smoke.
  • Replaceable Intake Bladder: The inflatable rubber on the patented intake bladder can be replaced easily with a screwdriver.
  • Detachable Components: Smoke hose and power cord are detachable for easy maintenance and storage.
VXSCAN V4 Smoke Leak Detector highlighting features
Figure 1: VXSCAN V4 Smoke Leak Detector with highlighted features including adjustable smoke output, adjustable pressure level, digital display pressure gauge, and wide applicability.

3. Functions and Applications

The VXSCAN V4 is capable of performing comprehensive diagnostics across various vehicle systems:

  • Full System Diagnostics: Designed to detect leaks across various vehicle systems, ensuring no leak is missed.
  • Digital Pressure Gauge: Provides precise, real-time pressure readings with adjustable output pressure.
  • Crankcase System Test: Identifies excessive pressure or corrosion in the crankcase that can lead to oil leakage.
  • Intake System Test: Detects leaks in the air intake system that cause insufficient air intake and reduced engine power.
  • Car Sealing Test: Checks for poor airtightness in the vehicle, which can affect cabin warmth, soundproofing, waterproofing, and dust-proofing.
  • Fuel Tank System Test: Locates gaps in the fuel tank and piping resulting from improper installation or insufficient sealing of the fuel tank cap.
  • Turbo Test: Helps identify coolant leaks that can cause the engine to report high water temperature.
  • Various Pipe Fitting Test: Suitable for smoke testing a wide range of hoses, including brake hoses, power steering hoses, cooling system hoses, air conditioning system hoses, turbocharger hoses, fuel hoses, and intake/exhaust system hoses.
  • EVAP System Test: Detects leaks in the fuel evaporation system that allow fuel vapor to escape into the atmosphere, leading to waste, pollution, or unstable engine idling.
  • Exhaust System Test: Pinpoints leaks that result in unpurified harmful gases being discharged into the atmosphere or increased vehicle noise.
Diagram of car systems testable by smoke leak detector
Figure 2: Overview of various automotive systems that can be tested for leaks using the VXSCAN V4.

4. Setup

Before operating the VXSCAN V4, ensure the following setup steps are completed:

  1. Prepare Test Oil: Fill 10ml-20ml of appropriate test oil into the detector's reservoir. Ensure not to overfill.
  2. Power Connection: Connect the detector to a DC12V vehicle battery using the provided power cord clamps. Ensure correct polarity (red to positive, black to negative).
  3. Hose Connection: Attach the smoke hose to the detector's smoke outlet.
  4. System Preparation: Identify the vehicle system you intend to test and prepare it for connection. This may involve disconnecting relevant pipes or hoses.

5. Operating Instructions

Follow these steps to perform a leakage test using the VXSCAN V4:

  1. Fill Test Oil: Ensure 10ml-20ml of test oil is in the detector.
  2. Connect to Vehicle System: Disconnect the relevant pipe (e.g., intake pipe) from the car and connect it to the detector using the appropriate adapter (e.g., standard cone adapter or intake bladder).
  3. Power On: Connect the detector to a DC12V battery. The device will start to work, and smoke generation will begin instantly.
  4. Adjust Output Pressure (if needed): The output pressure can be adjusted freely between 0.3psi and 17psi. Turn the top knob left to decrease pressure and right to increase it. To confirm the actual output pressure, block the smoke outlet; the displayed value will be the highest test pressure set. For EVAP systems, use 0.5psi; for other systems, 7-14psi; for special systems (turbo), greater than 14psi.
  5. Monitor Digital Pressure Gauge: The digital pressure gauge displays the real-time pressure of the system under test.
  6. Switch Units/Calibrate Pressure: Four kinds of units (psi, bar, kpa, kg/cm2) can be switched. There is a small hole under the digital display window; use a thin iron wire (max 2mm diameter) to short press and switch units. To perform pressure calibration (return to zero), press and hold the button. During calibration, ensure no load is connected to allow smooth output and prevent the system from holding pressure.
  7. Identify Leak Points: As the pipe fills with smoke, visually inspect for smoke escaping from any part of the system, indicating a leak.
  8. Complete Test: The device operates on a smart 5-minute working cycle. You can stop the test at any time or trigger another cycle if needed.
Step-by-step guide on how to perform a leakage test
Figure 3: Visual guide for performing a leakage test with the VXSCAN V4.

6. Maintenance

Proper maintenance ensures the longevity and optimal performance of your VXSCAN V4 Smoke Leak Detector:

  • Clean After Use: After each use, ensure the device and its accessories are clean. Wipe down any oil residue.
  • Check Test Oil Level: Regularly check the test oil level and refill as necessary. Use only recommended test oil.
  • Inspect Hoses and Connections: Periodically inspect the smoke hose, power cord, and adapters for any signs of wear, cracks, or damage. Replace if necessary.
  • Replace Intake Bladder: The inflatable rubber on the intake bladder is replaceable. If it becomes damaged or worn, replace it using a screwdriver.
  • Storage: Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. Utilize the built-in hook for convenient storage.

7. Troubleshooting

This section addresses common issues you might encounter with your VXSCAN V4 Smoke Leak Detector:

  • No Smoke Output:
    • Check if the device is properly connected to a DC12V power source.
    • Ensure there is sufficient test oil in the reservoir.
    • Verify that the smoke hose is not blocked or kinked.
    • Check for any error indications on the LED display.
  • Incorrect Pressure Reading:
    • Ensure the digital pressure gauge is calibrated. Perform a pressure calibration by pressing and holding the unit switch button without any load connected.
    • Check for proper connection to the vehicle system; a loose connection can affect readings.
  • Device Overheating:
    • The device has over-heat protection. If it overheats, it will indicate via LED. Allow the device to cool down before resuming operation.
    • Ensure adequate ventilation around the device during operation.
  • Smoke Leaking from Device Itself:
    • Check that all caps and connections on the device are securely tightened.
    • Inspect the intake bladder for any damage and replace if necessary.

If you encounter issues not listed here or if the problem persists, please contact customer support for assistance.

8. Specifications

Attribute Specification
Model Name SO665 (V4)
Item Type Smoke Leak Detector
Hardware Version Smoke Leak Detector
Output Pressure Adjustable 0.3psi - 17psi
Pressure Gauge Digital (Units: psi, bar, kpa, kg/cm2)
Greatest Pressure 1.1 - 1.3 bar
Maximum Gas/Smoke Flow 6 liters/min @ max pressure
Power (W) NA
Voltage NA (Operates on DC12V vehicle battery)
Item Weight 3 kg
Item Length 29 cm
Item Width 24 cm
Item Height 17 cm
Material Plastic
External Testing Certification CE
Origin Mainland China
Is Batteries Included No
Comparison table of VXSCAN V3 and V4 models
Figure 4: Comparison of key specifications between VXSCAN V3 and V4 models.

9. Package Contents

The VXSCAN V4 Smoke Leak Detector package typically includes the following items:

  • 1x VXSCAN V4 Main Unit
  • 1x Standard Cone Adapter
  • 1x Funnel
  • 1x Replacement Rubber
  • 1x Intake Bladder
  • 1x Smoke Hose
  • 1x Power Cord Clamp
  • 1x EVAP Valve Removal Tool
  • 1x EVAP Service Port Adapter
  • 1x Test Oil Refill Bottle (oil not included)
Image of VXSCAN V4 package contents
Figure 5: Contents included in the VXSCAN V4 Smoke Leak Detector package.

10. User Tips

While no specific user reviews or Q&A were provided, here are some general tips for optimal use:

  • Always ensure the test oil is at the recommended level before starting a test to prevent damage to the device and ensure consistent smoke output.
  • When testing, start with lower pressure settings and gradually increase if necessary, especially for sensitive systems.
  • For hard-to-find leaks, consider using a bright flashlight or UV dye (if compatible with your test oil) to enhance visibility of smoke.
  • Keep all connections tight to prevent smoke leakage from the setup itself, which could lead to misdiagnosis.

11. Warranty and Support

The manufacturer is committed to providing excellent after-sales service. If you encounter any issues or require assistance with your VXSCAN V4 Smoke Leak Detector, please refer to the contact information provided with your purchase or reach out to the seller directly. They are dedicated to doing their best to help you resolve any concerns.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.