OLOEY ST-B268D

Contents

User Manual: OLOEY Digital Refrigeration Manifold Gauge

Model: ST-B268D (also applicable to ST-B168D series)

This manual provides instructions for the safe and efficient operation, maintenance, and troubleshooting of your digital refrigeration manifold gauge.

1. Product Overview

The OLOEY Digital Refrigeration Manifold Gauge (Model ST-B268D) is an advanced diagnostic tool designed for the installation, testing, and maintenance of refrigeration equipment such as air conditioners, refrigerators, and cold storage units. It integrates a digital circuit with high-precision pressure sensors to accurately measure both refrigerant pressure and vacuum pressure. The device features a built-in database of over 90 refrigerants, allowing for real-time calculation of subcooling and superheat, simplifying operational data reading.

OLOEY Digital Refrigeration Manifold Gauge kit with hoses and accessories

Figure 1: Complete OLOEY Digital Refrigeration Manifold Gauge kit including the main unit, hoses, and connectors.

Key Features:

  • Three Common Working Modes: Refrigerant measurement, vacuum measurement, and leak detection.
  • Built-in Refrigerant Data: Contains data for over 90 types of refrigerants (e.g., R22, R32, R600, R410a, R134a) based on US NIST standards.
  • High Precision: Utilizes a 32-bit digital processing unit and high-precision data acquisition for stable and accurate readings.
  • Digital Readout: Clear LCD display with backlight for easy reading, supporting automatic multi-unit pressure conversion and Celsius/Fahrenheit temperature conversion.
  • Durable Design: Features a textured shockproof sheath, manual ball valve design, and an aluminum alloy body for enhanced durability.
  • Convenient Operation: Includes a foldable adhesive hook for easy hanging and multi-angle bendable refrigerant pipes.
  • Automatic Shutdown: Automatically powers off after 10 minutes of inactivity (can be switched off).

2. Components and Controls

Familiarize yourself with the various components and controls of the digital manifold gauge before operation.

Diagram showing the components of the digital manifold gauge including low-voltage display, high-pressure display, low voltage button, high pressure button, low voltage knob, high pressure knob, low pressure intake connector, high pressure intake connector, outlet tee joint, and folding adhesive hook.

Figure 2: Front view of the digital manifold gauge with labeled components.

Main Components:

  • Low-voltage display window: Shows low-side pressure and related data.
  • High-pressure display window: Shows high-side pressure and related data.
  • Low voltage button: Controls functions related to the low-pressure side.
  • High pressure button: Controls functions related to the high-pressure side.
  • Low pressure knob (LOW): Controls the low-pressure valve.
  • High pressure knob (HIGH): Controls the high-pressure valve.
  • Low pressure intake connector: Connection point for the low-pressure hose.
  • High pressure intake connector: Connection point for the high-pressure hose.
  • Outlet tee joint: Central connection point for vacuum pump or refrigerant tank.
  • Folding adhesive hook: For hanging the unit during use.
  • Exhaust valve thimble: Used for purging air from the system.
  • Sight glass: Allows visual observation of refrigerant flow.
Close-up of acid and alkali resistant colloidal particles in the refrigerant hoses.

Figure 3: Close-up of the acid and alkali resistant colloidal particles within the hoses, ensuring good air tightness and corrosion resistance.

3. Setup and Installation

3.1 Battery Installation

The unit requires two 9V lithium batteries for operation.

  1. Locate the battery compartment on the back of the main unit.
  2. Open the battery cover.
  3. Connect the two 9V batteries to the battery clips, ensuring correct polarity.
  4. Place the batteries into the compartment and close the cover securely.
Play video
Watch video online

Video 1: Product demonstration showing battery installation, valve operation, refrigerant selection, and backlight control.

3.2 Connecting Hoses

The kit includes three test pipes (hoses) and two connectors. Ensure all connections are tight to prevent leaks.

  1. Connect the blue hose to the low pressure intake connector (LOW).
  2. Connect the red hose to the high pressure intake connector (HIGH).
  3. Connect the yellow hose to the outlet tee joint. This hose is typically used for connecting to a vacuum pump or refrigerant tank.
  4. Attach the reducer joints (connectors) as needed for compatibility with your system.
Digital manifold gauge with three colored hoses (red, yellow, blue) and connectors laid out.

Figure 4: Digital manifold gauge with included hoses and connectors.

4. Operating Instructions

4.1 Power On/Off and Backlight

  • Press the power button (usually marked with a circle and a vertical line) to turn the unit ON or OFF.
  • Press the backlight button (often depicted as a light bulb or sun icon) to toggle the LCD backlight.

4.2 Valve Operation

The low and high pressure knobs control the flow of refrigerant. Turn them clockwise to close (OFF) and counter-clockwise to open (ON).

  • LOW knob: Controls the low-pressure side valve.
  • HIGH knob: Controls the high-pressure side valve.
  • Exhaust valve thimble: Used to purge air from the system.

4.3 Mode Selection and Refrigerant Type

The device supports three main modes: refrigerant measurement, vacuum measurement, and leak detection. Refer to the on-screen prompts and the specific buttons (e.g., 'M' for mode, '+' and '-' for selection) to navigate and select the desired mode and refrigerant type.

  • Refrigerant Type Selection: Use the appropriate buttons (often '+' and '-') to cycle through the built-in refrigerant types (e.g., R11, R21, R22, R218, R227EA, etc.) displayed on the screen.
  • Pressure/Temperature Display: The digital displays will show pressure readings (in KPa, Bar, PSI, InHg, KgF/cm2) and corresponding temperatures (in °C or °F) based on the selected refrigerant.

4.4 Common Operations:

  • Evacuation: Connect the yellow hose to a vacuum pump. Open the valves as required by the vacuum pump instructions and monitor the vacuum percentage on the gauge.
  • Fluoride Addition (Charging): Connect the yellow hose to the refrigerant tank. Ensure the system is properly evacuated. Open the appropriate valves to allow refrigerant to flow into the system, monitoring pressure and temperature.
  • Pressure Maintenance/Measurement: Connect the hoses to the high and low-pressure ports of the refrigeration system. The gauge will display real-time pressure and temperature readings.
  • Leak Detection: Use the leak detection mode to identify potential leaks in the system.
Image showing the digital manifold gauge with text 'Air conditioning fluorination tool' and labels for 'Take Time', 'Fluoride and pressure maintaining', and 'Pressure Measurement'.

Figure 5: The digital manifold gauge is used for air conditioning fluorination, pressure maintenance, and pressure measurement.

5. Maintenance

5.1 Cleaning

  • Wipe the unit with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Ensure connectors and hoses are free from debris before and after use.

5.2 Battery Replacement

  • When the battery indicator shows low power, replace both 9V batteries promptly to ensure accurate readings.
  • Follow the battery installation steps in Section 3.1.

5.3 Storage

  • Store the unit and accessories in the provided suitcase to protect them from damage.
  • Keep the unit in a cool, dry place away from direct sunlight and extreme temperatures.
  • Remove batteries if storing for extended periods to prevent leakage.
Black carrying case for the digital manifold gauge with a green handle.

Figure 6: High-quality carrying case for the digital manifold gauge, designed for durability and portability.

6. Troubleshooting

Common Issues and Solutions:

ProblemPossible CauseSolution
No display/Unit won't turn onDead or improperly installed batteries.Check battery installation; replace with fresh 9V batteries.
Inaccurate readingsIncorrect refrigerant selected; sensor calibration issue; leaks in connections.Verify selected refrigerant type; ensure all hose connections are tight; if issue persists, contact support for calibration.
Backlight not workingBacklight feature turned off; low battery.Press the backlight button; replace batteries if low.
Unit automatically shuts off too soonAuto power-off function is enabled.Disable the auto power-off function (refer to the detailed user manual for specific steps, usually involves holding a button during power-on).

If you encounter problems not listed here or if solutions do not resolve the issue, please refer to the comprehensive user manual included with your product or contact customer support.

7. Specifications

General Specifications:

  • Brand Name: OLOEY
  • Model Number: ST-B268D (High pressure model: ST-B168DH, Low voltage model: ST-B168DL)
  • Display Type: DIGITAL
  • Certification: CE
  • Origin: Mainland China
  • Item: Pressure Temperature Tester

Technical Parameters:

ParameterValue
Battery VoltageDC 9V (2x 9V lithium batteries)
Max Measuring Range200 PSI & Above (0 KPa ~ 6000 KPa)
Negative Pressure Measurement-101 KPa ~ 0 KPa
Fluorination Range0 ~ 40 kg
Pressure UnitsKPa, Bar, PSI, InHg, KgF/cm2, Torr, mmHg
Temperature Units℃ (Celsius), ℉ (Fahrenheit)
Resolution1 KPa
Sensing Accuracy±0.5%
Overload Limit10 MPa
Operating Temperature Range-20℃ ~ 60℃ / -4℉ ~ 140℉
Automatic Shutdown10 minutes (switchable, default ON)
Fluorine Tube Length150cm * 3 pieces (for double table models)
Reducer Joint410 reducer * 2 (for double table models)
Main Unit Dimensions170 x 170 x 60 mm / 6.69 x 6.69 x 2.36 inches
Package Weight3.0 kg
Package Dimensions34 cm (Length) x 31 cm (Width) x 12 cm (Height)
Table listing 90 types of refrigerants by number and name.

Figure 7: Partial list of applicable refrigerants supported by the device.

Package Contents:

  • 1 x Digital manifold gauge
  • 3 x Test pipe (hoses)
  • 2 x Connector
  • 1 x User manual (this document)
  • 1 x Suitcase

8. Warranty and Support

This product is covered by standard warranty terms. For specific warranty details, please refer to the warranty card included in your package or contact the seller directly.

Customer Support:

  • For technical assistance, troubleshooting, or warranty claims, please contact your point of purchase or the manufacturer's customer service.
  • Free Returns: Within 90 days (as per AliExpress policy).
  • Fast Delivery Guarantee: Includes a $1.00 coupon if delivery is delayed, refund if the package is lost, and refund if items are damaged.
  • Security & Privacy: Your personal details are protected and not shared with third parties without consent.

Note: Light shooting and different displays may cause the color of the item in the picture to be slightly different from the real product. The measurement allowed error is +/- 1-3cm.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.