EARU EA119G, EA219G, EA319G, EA419G

EARU Din Rail Modular Manual Transfer Switch Circuit Breaker

Models: EA119G, EA219G, EA319G, EA419G

Instruction Manual

1. Introduction

The EARU Dual Power Manual Transfer Switch (MTS) is a versatile electrical device designed for switching between two power sources or loads. It offers four primary functions: ON, OFF, Conversion, and Isolation. This manual provides detailed instructions for the safe and effective installation, operation, and maintenance of your EARU MTS circuit breaker.

This product is ideal for industrial equipment and circuits where reliable switching and isolation are critical. It is designed for installation on a standard 35mm DIN rail.

2. Product Features

  • Dual Power Capability: Seamlessly switch between main and standby power supplies.
  • Manual Operation: Operator-controlled switching for precise power management.
  • High Performance: Features millisecond switching, quick switch functionality, and interlocking conversion.
  • Durable Construction: Made from high flame-retardant PA66 injection molding and thermoset housing, ensuring resistance to high temperatures.
  • Ergonomic Design: Large D-shaped handle with comfortable buttons for easier and more comfortable operation.
  • Easy Installation: Designed for 35mm DIN rail mounting with securing clips.
  • Reliable Wiring: Tunnel-type terminal blocks ensure tight and reliable wire connections.
  • Safety Certified: CE certified, meeting European safety standards.
Features of EARU Manual Transfer Switch
Key features including millisecond switching and flame-retardant material.
Detailed features of the switch
Detailed view of the ergonomic handle, PC flame-retardant material, 35mm rail mounting, and tunnel-type terminal block.

3. Setup and Installation

Safety First: Before beginning any installation, ensure that all power to the circuit is disconnected at the main breaker. Always consult with a qualified electrician if you are unsure about any steps.

  1. Mounting: The EARU MTS is designed for 35mm DIN rail installation. Securely attach the switch to the DIN rail within your household lighting distribution box or industrial control panel.
  2. Wiring: The switch typically features two power input terminals (main and standby) and one output terminal. Connect your main power supply to the designated input terminals (e.g., 'I' position), and your standby power supply to the other input terminals (e.g., 'II' position). Connect the load to the output terminals.
  3. Terminal Connections: Use appropriate cable sizes (up to 16mm²) and ensure all connections are tight within the tunnel-type terminal blocks for reliable operation.
35mm DIN Rail Installation
Example of 35mm standard rail installation in a distribution box.

Wiring Diagrams:

Refer to the following diagrams for correct wiring based on the number of poles:

1P Wiring Diagram
Wiring Diagram for 1-Pole (1P) configuration. Connect 'Noraml' (Normal) power to terminals 2 and 4, 'Ready' (Standby) power to terminals 2 and 4, and 'Load' to terminals 1 and 3.
2P Wiring Diagram
Wiring Diagram for 2-Pole (2P) configuration. Connect 'Noraml' (Normal) power to terminals 2 and 4, 'Ready' (Standby) power to terminals 6 and 8, and 'Load' to terminals 1, 3, 5, and 7.
3P Wiring Diagram
Wiring Diagram for 3-Pole (3P) configuration. Connect 'Noraml' (Normal) power to terminals 2, 4, and 6, 'Ready' (Standby) power to terminals 8, 10, and 12, and 'Load' to terminals 1, 3, 5, 7, 9, and 11.
4P Wiring Diagram
Wiring Diagram for 4-Pole (4P) configuration. Connect 'Noraml' (Normal) power to terminals 2, 4, 6, and 8, 'Ready' (Standby) power to terminals 10, 12, 14, and 16, and 'Load' to terminals 1, 3, 5, 7, 9, 11, 13, and 15.

4. Operating Instructions

The EARU Manual Transfer Switch allows you to manually select the desired power source for your load. The handle has three distinct positions:

  • Position I (Common Power): Connects the load to the main power supply.
  • Middle Position (Disconnect/OFF): Disconnects the load from both power supplies. All circuits are open.
  • Position II (Standby Power): Connects the load to the standby power supply.

To switch between power sources, simply manipulate the handle to the desired position. Ensure a firm and complete movement of the handle to engage the selected power supply or to fully disconnect.

Instructions for Operating the Switch
Visual guide for operating the switch: Common Power (I), Disconnect (Middle), and Standby Power (II).
Dual Power Isolating Switch in action
The dual power isolating switch can normally connect to the load and disconnect the circuit, serving as a switching isolator.
Video demonstrating the manual operation of the dual power transfer switch, showing how to switch between main and standby power supplies.

5. Maintenance

  • Regular Inspection: Periodically check the switch for any signs of physical damage, loose connections, or overheating.
  • Cleaning: Keep the switch free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquids or abrasive cleaners.
  • Terminal Tightness: Ensure all terminal screws remain tight to prevent arcing and ensure proper electrical contact.
  • Material Durability: The thermoset housing is designed for high temperatures, but avoid exposing the device to extreme heat sources beyond its specified ambient temperature range.
Thermoset Housing
The thermoset housing ensures durability and resistance to high temperatures.

6. Troubleshooting

  • No Power to Load:
    • Check if the switch handle is fully engaged in either Position I or Position II.
    • Verify that both the main and standby power sources are active.
    • Inspect wiring connections for looseness or damage.
  • Switch Feels Stiff:
    • Ensure no foreign objects are obstructing the handle mechanism.
    • The mechanism is designed for manual operation; apply firm, steady pressure.

7. Specifications

Product Dimensions and Parameters
Dimensions and key electrical parameters for the EARU MTS.
Technical Specifications
Attribute Value
Model Numbers EA119G, EA219G, EA319G, EA419G
Type Mini Circuit Breaker / Dual Power Manual Transfer Switch
Number of Poles 1P, 2P, 3P, 4P
Rated Voltage 1P: AC230V; 2P/3P/4P: AC400V
Rated Current 40A / 63A
Rated Frequency 50/60Hz
Electrical Life 1500 cycles
Mechanical Life 8500 cycles
Ambient Temperature -5℃ ~ 40℃
Protection Degree IP20
Terminal/Cable Size 16mm²
Standard IEC/EN 60947-3
Certification CE
Is Smart Device No

8. User Tips

  • Overload Protection: While this device functions as a circuit breaker, it is primarily designed for switching and isolation. For comprehensive overload and short-circuit protection, ensure it is installed in conjunction with appropriate upstream protective devices (e.g., MCBs or RCDs) in your electrical system.
  • CE Certification: This product is CE certified, confirming its compliance with European safety, health, and environmental protection requirements.

9. Warranty and Support

For any questions, technical assistance, or warranty claims, please contact the EARU Official Store customer support. Keep your purchase records for reference.

Related Documents - EA119G, EA219G, EA319G, EA419G

Preview EARU EAL-2 Din Rail Circuit Breaker Instruction Manual
Instruction manual for the EARU EAL-2 series din rail circuit breaker, detailing its features, safety instructions, and product parameters for AC 2P 230V 4P 400V A Type RCBO RCCB MCB electronic residual current circuit breakers.
Preview EARU Automatic Transfer Switch (ATS) Operating Instruction and Technical Specifications
Comprehensive operating instructions and technical specifications for the EARU Automatic Transfer Switch (ATS) model EAATS-F-CG-80. Covers product overview, working conditions, model breakdown, detailed technical parameters, installation guidelines, maintenance procedures, and wiring diagrams.
Preview EARU EAPDX-40/63 Series Adjustable Voltage & Current Protector User Manual
User manual for the EARU EAPDX-40/63 Series Adjustable Voltage & Current Protector, detailing specifications, features, and operation for electrical protection. Includes setup instructions and parameter configuration.
Preview EARU-X6/8 Metal LED Indicator Light Instruction Manual
User manual for EARU-X6/8 series Metal LED Indicator Lights, detailing safety instructions, warnings, and product description for reliable status indication in industrial and traffic applications.
Preview EARU KR0548-CH WiFi Smart Automatic Transfer Switch (ATS) User Manual
User manual for the EARU KR0548-CH WiFi Smart Automatic Transfer Switch (ATS). Learn how to install, connect, and operate the device using the EARU app for seamless switching between main and backup power sources.
Preview EARU D52-2066 Series Single Phase Multi-functional Energy Meter | Technical Specifications
Detailed technical specifications and wiring instructions for the EARU D52-2066 Series DIN-rail single-phase multi-functional energy meter, measuring AC voltage, current, active power, power factor, frequency, and electric energy.