1. Product Overview
The LEIRONG ZP600 is a versatile DC speed control peristaltic pump designed for precise fluid transfer in various applications, including laboratories, production lines, and aquariums. It features adjustable flow rates, bidirectional operation, and a user-friendly manual knob for speed control.

Figure 1: Front view of the LEIRONG ZP600 Peristaltic Pump.
Key Features:
- Knob speed control for simple operation.
- Spring compensation structure to extend pump tube life and prevent backflow.
- Multi-gear collaborative drive for long life and low noise.
- Double bearing support for maintenance-free operation.
- Transparent housing for visible work.
- Easy tube change and adjustable flow direction.
- 24V DC power supply for safe low voltage operation.
2. Setup
2.1 Unpacking and Component Identification
Carefully unpack all components from the box. Verify that all items listed in the packing list are present:
- 1 x LEIRONG ZP600 Peristaltic Pump
- 1 x Power Adapter
- 1 x PVC Tube (2 meters)

Figure 2: ZP600 pump with included accessories.
2.2 Placement
Place the pump on a stable, flat surface. Ensure there is adequate space around the pump for ventilation and easy access to controls and tubing.
2.3 Tube Installation
The ZP600 pump head is designed for quick and easy tube changes. Follow these steps:
- Insert a flat-head screwdriver into the fixing port and turn the cover clockwise to open it.
- Open the lever and slider mechanism.
- Remove the existing pump tube (if any).
- Insert the new pump tube, ensuring it is properly seated within the pump head rollers.
- Close the lever and slider, then close the cover by turning it counter-clockwise.

Figure 3: Tube change procedure diagram.
The pump head direction can be adjusted if needed for specific setups.
2.4 Power Connection
Connect the provided power adapter to the pump's power input port. Plug the power adapter into a suitable electrical outlet (100-240V AC). The pump is designed for plug-and-play operation.

Figure 4: Plug and Play setup.
3. Operating Instructions
3.1 Powering On/Off
Once connected to power, the pump is ready for operation. There is no separate power switch; operation is controlled via the speed knob and direction switch.
3.2 Speed and Flow Rate Adjustment
The ZP600 features a manual knob for precise speed control, which directly adjusts the flow rate:
- Turn the knob clockwise to increase the pump speed and flow rate.
- Turn the knob counter-clockwise to decrease the pump speed and flow rate.
3.3 Direction Control (Forward/Reverse)
A toggle lever switch on the front panel controls the direction of fluid flow:
- Toggle the lever to one side for forward rotation (e.g., dispensing fluid).
- Toggle the lever to the opposite side for reverse rotation (e.g., drawing fluid back).
- Set the lever to the middle position to pause the pump's operation.

Figure 5: Bidirectional conveying with CCW/CW switch.
3.4 Operational Demonstration
Video 1: Demonstration of ZP600 Peristaltic Pump operation, including flow rate adjustment and direction control.
4. Maintenance
4.1 Pump Tube Replacement
The pump tube is a consumable part and should be replaced periodically based on usage, fluid corrosiveness, and operational conditions. Refer to Section 2.3 for detailed tube installation/replacement steps.
4.2 Cleaning
Regularly clean the exterior of the pump with a soft, damp cloth. Avoid using abrasive cleaners or solvents that could damage the housing. If the pump head or tubing becomes contaminated, clean or replace the tubing as necessary.
4.3 General Care
- Ensure the pump is operated within the suggested working conditions (ambient temperature 0-50°C, relative humidity <80%).
- Avoid exposing the pump to direct sunlight or extreme temperatures.
- Do not immerse the pump in water or any other liquid.
5. Troubleshooting
5.1 No Flow or Inconsistent Flow
- Check Power: Ensure the power adapter is securely connected to both the pump and the power outlet.
- Check Tubing: Verify that the pump tube is correctly installed, not kinked, blocked, or worn out. Replace the tube if necessary.
- Check Direction: Ensure the direction control lever is not in the middle (pause) position and is set to the desired flow direction.
- Check Speed Knob: Confirm the speed knob is turned up from the minimum setting.
5.2 Unusual Noise
- Check Tubing: Ensure the tubing is not rubbing against any part of the pump or surrounding objects.
- Check Pump Head: Verify that the pump head cover is securely closed.
- Internal Issue: If unusual noise persists, contact support.
6. Specifications
| Feature | Specification |
|---|---|
| Model Number | ZP600 |
| Brand Name | LEIRONG |
| Power Source | Electric |
| Application | Metering, Laboratory, Production Line, Aquarium |
| Structure | Peristaltic Pump |
| Origin | China Mainland |
| Certification | CE, RoHS, ISO9001 |
| Flow Rate Range | 160-750 ml/min |
| Pump Tube Lifetime | Norprene: ≥1000H, Silicone: ≤200H |
| Motor Type | DC Motor |
| Rollers Quantity | 3 |
| Input Voltage | 100-240V AC |
| Operating Voltage | 4.5V / 24V (depending on model variant) |
| Weight | 1580g |
| Standard Pump Tube | Norprene |
| Noise Level | ≤60dB |
| Power | 20W |
| Dimensions (L x W x H) | 137mm x 94mm x 109mm |

Figure 6: ZP600 Product Dimensions.
7. User Tips
- Verify Model: Upon receiving your pump, always verify that the model number matches your order to ensure it meets your specific power and flow requirements.
- Understand Flow Range: Familiarize yourself with the pump's minimum and maximum flow rates (160-750 ml/min) to ensure it is suitable for your intended application.
- Tube Material Selection: Choose the appropriate pump tube material (Norprene for longer life and chemical resistance, Silicone for general use) based on the fluid being pumped and required lifespan.
8. Warranty and Support
For warranty information, technical support, or service inquiries, please contact LEIRONG customer service or your authorized dealer. Keep your purchase receipt as proof of purchase.