1. Introduction
The CEM DT-9935 is a professional digital LCR meter designed for accurate and reliable measurement of inductance (L), capacitance (C), and resistance (R). Featuring an 11000-bit LCD display, series/parallel dual mode, and full-range protection, this meter is an essential tool for electronics enthusiasts, technicians, and engineers. It provides accurate, fast, and secure measurements for a wide range of electrical and electronic testing applications.
2. Key Features
- 11000-Bit LCD display for clear readings.
- Series/parallel dual mode for versatile component analysis.
- Full range protection ensures durability and safety.
- Automatic identification of capacitance, inductance, and resistance frequency.
- Accurate, fast, and secure measurement capabilities.
- Sampling rate of 5 times per minute.
- Overrange prompt: "OL" or "-OL".
- Automatic shutdown after 10 minutes of inactivity to conserve battery.
- Complies with IEC61000EMC standard for security.
3. Package Contents
Upon unpacking, please verify that all items listed below are present and in good condition:
- 1 x CEM DT-9935 Digital LCR Meter
- 1 x Set of Test Leads (Red and Black)
- 1 x User Manual (this document)
4. Setup
4.1 Battery Installation
- Locate the battery compartment cover on the back of the meter.
- Open the cover by sliding or unscrewing it.
- Insert four (4) 1.5V "AA" batteries (15A or IE CLR 6 type recommended), ensuring correct polarity as indicated inside the compartment.
- Close the battery compartment cover securely.
4.2 Connecting Test Leads
- Insert the red test lead into the positive ("+") input terminal.
- Insert the black test lead into the negative ("-") input terminal.
- For guarded measurements, connect the guard leads to the "GUARD" terminals to minimize stray capacitance and improve accuracy.
5. Operating Instructions
5.1 Power On/Off
- Press the red power button (POWER) to turn the meter ON. The meter will perform a self-test and display the default measurement mode.
- Press and hold the power button to turn the meter OFF.
5.2 Measurement Modes and Functions
Safety Precaution: Always discharge capacitors before testing to prevent damage to the meter and ensure user safety. A warning is printed on the device: "Discharge Capacitor Before Testing".
- LCR Measurement (Auto): The meter automatically identifies inductance (L), capacitance (C), and resistance (R). Connect the component to the test leads.
- Function Selection (FUNC): Use the FUNC button to cycle through different measurement parameters such as Cp (parallel capacitance), Cs (series capacitance), Lp (parallel inductance), Ls (series inductance), Rp (parallel resistance), Rs (series resistance), D (dissipation factor), Q (quality factor), and ESR (equivalent series resistance).
- Frequency Selection (FREQ): Use the FREQ button to select the desired test frequency (e.g., 10 KHz).
- Series/Parallel Mode (SER/PAL): Use the SER/PAL button to switch between series and parallel equivalent circuit modes for capacitance and inductance measurements, depending on the component and application.
- Hold Function (HOLD): Press HOLD to freeze the current reading on the display. Press again to release the hold function.
- Relative Measurement (REL%): Use the REL% button for relative measurements, allowing you to measure the difference from a stored reference value.
- Sorting Function (SORTING): Use the SORTING button for component sorting based on predefined criteria.
- Setup (SETUP): Accesses meter settings.
- Calibration (CAL): Used for calibration procedures.
- Enter (ENTER): Confirms selections.
6. Maintenance
6.1 Cleaning
Wipe the meter with a dry, soft cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these may damage the casing or display.
6.2 Battery Replacement
Replace the batteries when the low battery indicator appears on the display to ensure accurate measurements and proper operation.
6.3 Storage
Store the meter in a cool, dry place away from direct sunlight, high humidity, and extreme temperatures. If the meter will not be used for an extended period, remove the batteries to prevent leakage and damage.
7. Troubleshooting
- "OL" or "-OL" Display: This indicates an overrange condition. The measured value exceeds the meter's maximum range for the selected function. Check the component or switch to a higher range if applicable.
- No Display/Power: Check battery installation and ensure the batteries have sufficient charge. Verify that the power button is pressed correctly.
- Inaccurate Readings: Ensure test leads are properly connected and making good contact with the component. Clean the test leads and terminals if necessary. Perform a calibration if readings remain inconsistent.
8. Specifications
8.1 Product Parameters (Technical Indicators)
| Parameter | Range | Resolution | Error |
|---|---|---|---|
| Inductance | |||
| Inductance | 20µH – 2000H | 0.001µH | ± (0.2 + 5d) |
| Capacitor | |||
| Capacitor | 20pF – 20mF | 0.001pF | ± (0.2 + 3d) |
| Electronic Resistance | |||
| Electronic Resistance | 20Ω – 2000MΩ | 0.001Ω | ± (0.2 + 2d) |
| DC Electronic Resistance | |||
| DC Electronic Resistance | 20Ω – 2000MΩ | 0.001Ω | ± (0.2 + 2d) |
| Q (Quality Factor) | |||
| Q (Quality Factor) | 0.000 – 999 | 0.001 | |
| D (Dissipation Factor) | |||
| D (Dissipation Factor) | 0.000 – 999 | 0.001 | |
| Theta (Phase Angle) | |||
| Theta | ± 90 degrees | 1 degree | |
8.2 General Specifications
| Feature | Specification |
|---|---|
| Sampling rate | 5 times/minute |
| Overrange prompt | OL or -OL" |
| Automatic shutdown | 10 minutes |
| Operating temperature | 0~50°C, <80% R. H. |
| Storage Temperature | -20~60°C |
| Temperature coefficient | 0.15(PEC.ACC) /C, <18 # or ≥ 28 # |
| Security | Comply with IEC61000EMC standard |
| Power requirements | 4 x 1.5V "AA" battery (15A or IE CLR 6 required) |
| Battery life | 30H (Alkaline battery) |
9. User Tips
- For precise measurements, ensure the test leads are clean and free from corrosion.
- Always double-check the selected measurement mode and frequency for the component being tested.
- The meter's automatic identification feature simplifies testing, but understanding the different parameters (Cp, Cs, Lp, Ls, D, Q, ESR) can enhance diagnostic capabilities.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase for any warranty claims.