LEIRONG CP2

Contents

LEIRONG CP2 DC Motor Peristaltic Pump User Manual

Model: CP2

1. Introduction

The LEIRONG CP2 DC Motor Peristaltic Pump is a compact, low-noise, and reliable pump designed for precise fluid transfer. It features a visual work design, gear drive for smooth operation, and a wear-resistant, long-service-life sync disk component. This pump is suitable for transporting both viscous and non-viscous liquids across various applications, offering easy maintenance with quick pump tube replacement.

LEIRONG CP2 DC Motor Peristaltic Pump overview

Figure 1: LEIRONG CP2 DC Motor Peristaltic Pump overview, highlighting its compact design and flow rate of up to 230ml/min.

Video 1: Product demonstration of the LEIRONG CP2 DC Motor Peristaltic Pump, showcasing its features and operation.

2. Safety Information

  • Electrical Safety: Ensure the pump is connected to the correct DC voltage (12V or 24V) as specified on the motor label. Do not expose the motor to water or other liquids. Disconnect power before performing any maintenance.
  • Chemical Compatibility: Always verify that the pump tube material (Silicone or BPT) is compatible with the fluid being pumped to prevent damage to the tube and ensure safe operation.
  • Operating Environment: Operate the pump within the suggested working conditions: ambient temperature 0-50°C and relative humidity <80%.

3. Setup

3.1. Installation Methods

The CP2 pump supports two primary installation modes: Mode A (panel mount) and Mode B (bracket mount). Refer to the diagrams below for detailed dimensions and mounting instructions.

Installation Method A and B dimensions

Figure 2: Detailed dimensions for Installation Mode A (panel mount) and Mode B (bracket mount).

Type A and B Installation Diagrams and Pump Head Removal

Figure 3: Visual guide for Type A and Type B installation, showing how the pump integrates into a system.

3.2. Tubing Connection

Connect your inlet and outlet tubing to the pump head. Ensure the tubing is securely fitted to prevent leaks. The orientation of the entrances and exits is crucial for correct flow direction. The pump head removal diagram (Figure 3) also illustrates the 'OUT' and 'IN' ports.

4. Operating Instructions

4.1. Powering On

Once installed and tubing is connected, apply the specified DC voltage (12V or 24V) to the motor terminals. The pump will begin operation.

4.2. Flow Rate

The flow rate of the CP2 pump depends on the selected pump tube material (Silicone or BPT), tube species (IDxOD), and the operating voltage. Refer to the table below for typical flow rates.

Tube Materials and Flow Rate Table

Figure 4: Flow rates for different tube materials (Silicone, BPT) and sizes (S30, S46, B30, B46) at 12V and 24V. Data is for reference only.

4.3. Model Definition

The pump model designation provides information about its configuration:

Model Definition CP2-DCXXBXXA/B

Figure 5: Explanation of the CP2 model number: 1. DC Motor (DC24: 24V, DC12: 12V), 2. Tube Type (S: Silicone, B: BPT), 3. Installation Mode (A mode, B mode).

5. Maintenance

5.1. Pump Tube Replacement

The pump tube is a consumable part and should be replaced periodically based on usage and fluid type. Follow these steps:

  1. Rotate the pump head counterclockwise and then remove it.
  2. Release the latch outwards and take out the pump pipe assembly.
  3. Remove the old pump tube from the assembly.
  4. Replace with a new pump tube, ensuring it is correctly seated.
  5. Reassemble the pump pipe assembly and pump head.
Change The Tube instructions

Figure 6: Step-by-step visual guide for replacing the pump tube.

5.2. Cleaning

The CP2 peristaltic pump is designed to be clean and hygienic, as the liquid only comes into contact with the pump tube. If cleaning is required, flush the system with an appropriate cleaning solution compatible with the pump tube material. No internal cleaning of the pump mechanism is typically needed.

Clean and Hygienic diagram

Figure 7: Diagram illustrating that only the pump tube contacts the liquid, ensuring cleanliness.

6. Troubleshooting

  • No Flow:
    • Check if the pump is receiving power and the voltage is correct.
    • Inspect tubing for kinks or blockages.
    • Ensure the pump tube is correctly installed in the pump head.
  • Reduced Flow:
    • Check for any restrictions in the inlet or outlet tubing.
    • The pump tube may be worn and require replacement.
    • Verify the power supply is providing the correct voltage.
  • Excessive Noise:
    • Ensure the pump is securely mounted.
    • Check for any foreign objects near the pump head or motor.

7. Specifications

Item Value Specifications table

Figure 8: Key specifications of the LEIRONG CP2 DC Motor Peristaltic Pump.

ItemValue
Model NumberCP2
Flow Range0-230ml/min
Brand NameLEIRONG
ApplicationMetering, Experimental equipment, Medical equipment, Environmental protection equipment, Food machinery, Car wash machine, Milk tea machine, Hair washing bed, Swimming pool salt pump, Distributor
PressureLow Pressure
Power SourceElectric
Motor TypeDC Motor (Brush DC Motor)
Control ModeFullspeed / PWM speed regulation
Voltage12V / 24V
Weight130g
Pump TubeSilicone tube / BPT tube
Roller3-roller
Noise≤60dB
Power10W
StructurePeristaltic Pump, Reduction gear
Gear boxIndependent research and development of long life
Lifetime1000H (BPT tube)
CertificationCE, RoHS, ISO9001
PatentUtility model

8. User Tips

  • Tube Selection: Always ensure the correct pump tube material (Silicone or BPT) is selected for your specific application. This is crucial for chemical compatibility with the fluid being pumped and to maximize the service life of the tube. Refer to the 'Pump Tube Selection' table (Figure 9) for guidance.
  • Regular Inspection: Periodically inspect the pump tubing for signs of wear, cracks, or discoloration, especially when pumping abrasive or chemically aggressive fluids. Replace the tube promptly if any wear is observed to maintain performance and prevent leaks.
Pump Tube Selection table

Figure 9: Guide for selecting the appropriate pump tube material based on chemical resistance, temperature range, and expected life.

9. Warranty and Support

For warranty information, technical support, or any inquiries regarding your LEIRONG CP2 Peristaltic Pump, please contact your vendor or the manufacturer directly. Contact details can often be found on the product packaging or the manufacturer's official website.

For direct support, you may refer to the contact information provided in the product documentation:

  • Email: 15316363092@163.com
  • Tel/WeChat: 15316363092

© 2023 LEIRONG. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.